Siemens Desigo CC Compact for Building Automation Specification Texts
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-desigo-cc-compact-for-building-automation-specification-texts-9725863401.pdf |
---|---|
Type | |
Size | 833.20 KB |
Downloads |
Text Preview
Desigo CC Compact Building Automation Texts Technologies Texts Technologies Texts Notice information is subject to change without notice by Siemens Ltd Companies names and various data used in examples are unless otherwise noted No part of this document may be reproduced or in any form or by any means electronic or mechanical for any without the express written permission of Siemens Switzerland Ltd software described in this document is furnished under a license agreement may be used or copied only in accordance with license terms further information contact your nearest Siemens Switzerland Ltd Siemens Switzerland Ltd 2018 and Desigo CC Compact are registered trademarks of Siemens Ltd product or company names mentioned herein may be the trademarks of respective owners 2018 10 01 ID A6V11532818 en a 30 Technologies Texts of contents description 6 Management level 6 Management level requirements 6 User profiles 8 Graphics 9 Scheduler programs 10 Building automation and control system operation 11 Alarm handling 12 Event management 14 Report generation 14 Remote operation 15 data 16 17 General 17 Standard BACnet AMEV 17 Scalability and System Lifecycle 17 Technologies Texts Revision History Identification document ID is structured as follows A6Vnnnnnnnn en a 02 Revision History Index Edition Date Description Final edition for the version 3.0 Technologies Texts System description Management level Management level requirements information comes together at the management level The management level is the graphical interface for the operator to the automation station and the integrated plants and plant operator can display query process save or print any plant information via the peripheral at the management level System operation must be based on a simplified approach The are displayed in synoptic images and the values and states are presented and displayed products Siemens Desigo CC Compact or similar openness control system supports standard protocols used in building technology including BACnet DA Data Access Modbus and S7 product Siemens Desigo CC Compact or similar of data to external system via web services exchange of data values events and trend data between other building systems corporate or other supplemental services must be supported via web services product Siemens Desigo CC Compact or similar exchange via various subsystems several subsystems are used various data must be exchanged between the automation level temperature demand and coordination signals etc products Siemens Desigo CC Compact or similar self monitoring system must be capable of monitoring running applications printers and all connected The system must report an event in case of an exceptional state product Siemens Desigo CC Compact or similar analysis analysis on system and user activities must be available in chronological order product Siemens Desigo CC Compact or similar platform management station must be based on a SCADA platform that is compatible with the BACnet profile It must permit integration of any building installation including HVAC and lighting product Siemens Desigo CC Compact or similar system for building automation and control system data servers operator stations etc for the BAC system must be compatible with the most generally available Windows 64 bit operating system As a result the current version of Technologies Texts at least 6 months after release by Microsoft as well as a minimum of the last Version is Modifications to the customer network must be possible The BACS system must be installable on any common PC and offer a multitasking environment where a user can multiple applications simultaneously product Siemens Desigo CC Compact or similar term storage system must be able to store and archive data for a period of more than 10 years allowing as option segregation of stored data in different groups that can be tuned individually with different frequencies Remounting of offline archived data must also be allowed product Siemens Desigo CC Compact or similar functions software includes an online help context sensitive as well as indexed a glossary and can be by terms or sentences product Siemens Desigo CC Compact or similar up to dateness lifecycle system provider must offer a transparent product lifecycle to ensure the required consistency equipment offered for this project must be contained in the current product portfolio existing system environment must allow for easy and smooth integration of devices and product Siemens Desigo CC Compact or similar continuity used must have a label for a global standard that ensures inaction with products from manufacturers Products with these labels can also be combined if manufactured at of more than 10 years product Siemens Desigo CC Compact or similar requirements Embedded Intel Celeron N2930 Intel Atom E3827 Intel Celeron 4CJ1900 Hardware purpose embedded hardware is required for small and or mid sized sites The hardware software environment must fulfil the following definition Memory 8GB Hard disk 100GB SSD Network Card Gigabit speed Graphics Card Onboard graphics adapter with integrated processor Software environment Win10 IOT Enterprise 2016 LTSB Microsoft SQL Server 2014 Express Edition Requirements network subnet Technologies Texts Mbps up down Wake on LAN range server number of objects 10,000 product SIMATIC Nanobox IPC227E Hardware system up to three clients client server system is required for small and mid sized sites The hardware and software must fulfill the following definition Workstation Tower Core i5 high end for example Intel Core i5 4690K Core i7 mid range for Intel Core i7 Memory 16GB Hard disk 1 TB for example Western Digital Red Network card Gigabit speed Graphics card Onboard graphics adapter for example Intel 4600HD or Mid range graphics for example GeForce GT 730 AMD Radeon Radeon R7 250 software environment Windows 7 Professional Service Pack 1 64 bit Windows 10 Professional 64 bit Windows Server 2012 R2 or 2016 Microsoft