Siemens Desigo Marine Fire and Detection Equipment, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Desigo Fire Safety Fire and Detection Equipment FH 2071 UM I BP 62 I USCG XPLATE Architect Engineer Specifications Product Overview equipment is used with Desigo 252 Model FC2025 and 504 point Model addressable fire alarm control panels design allows for protection of in harsh climates and most parts used in Marine fire applications passed salt spray mist requirements Exceptional Degree of Protection per guidelines including Models FDO421 FDT421 and Siemens series devices properties of Model FH 2071 UM include gasket sealed outer door latches for secure closure wire braided corrosion resistant vibration 1 battery bracket which holds two batteries 1 AC line EMI filter set Model BP 62 provides back up power for Marine only installations Standby power 24VDC with metal jacket operable between 40 to176 80 with two 2 batteries per order USCG XPLATE is required for Marine in order to reduce radio interference RFI Ordered separately each faceplate fits over XTRI series devices 864 10th Edition Listed ULC S527 Listed ABS Type Approval Lloyd Register Type States Coast Guard USCG Approved Exceptional Degree of Protection CFR Title 46 Subpart 161.002 60 0 Fire and Detection Control is an advanced Siemens fire safety system for use with Desigo 252 point Model FC2025 or 504 point Model addressable FACPs for Marine specific installs and other harsh applications enclosure used in Marine applications is robust and weather resistant Its design is customized for Marine installs due to the conditions at sea equipment will regularly encounter In order to provide secure fastening Model FH 2071 UM shipment includes a fully gasket sealed outer door latches as well as wire braided corrosion resistant vibration isolators all Marine installations that use Siemens XTRI series devices a specific Model USCG XPLATE is required and must be ordered separately faceplate helps diminish RFI exposure and fits on the front of each XTRI module the system batteries Model BP 62 are used to provide back up power Each battery which rated at 16AH can withstand as low as 40 and as high as 176 80 Application Data equipment used in Marine applications generates and radiates radio energy If the equipment is not installed properly and is attempted be used in ways that are different from the instructions found in the manual A6V10519176 this could subsequently result in interference with communications the exception of the inner door the Marine enclosure Model FH 2071 is shipped complete A trained Siemens representative is required to wire assemble the Marine equipment at the site Actual FACPs are delivered in parts Pre installed components include one 1 EMI filter as well as 1 system battery bracket following components must be ordered separately 1 system operating unit 1 170W power supply components to specified order 2 16AH batteries material and option as required Pages 4 6 for the complete of individual orderable parts Desigo Marine Fire and Detection Equipment is UL 864 10th Edition Listed USCG per CFR Title 46 Subpart 161.002 60 0 Refer to Desigo 252 504 point panel datasheet 6815 for more data Model FH2071 UM Infrastructure Building Products Sheet 6822 usa siemens com fire Desigo Marine Equipment Marine Enclosure FH 2071 UM is the enclosure designed for use in Marine and other harsh environment installations 1 outer door one 1 backbox and one 1 battery come standard each Model FH 2071 UM The inner door Model FHD2004 U1 only in Black houses the system operating units FCM2018 U2 and FCM2019 U2 The system back box supports the fire terminal board FTI2001 U1 and optionally supports the DACT FCA2015 U1 as well as the releasing module XCI2001 U1 size 30.6 77.7 cm H 22 55.9 cm W 6.31 16 cm D weight 48 Lbs 21.8 kg Optional Accessories Batteries for Marine Applications rated at 16AH can operate in Marine applications the Model BP 62 battery set auxiliary emergency standby power at 24VDC in of system power failure from the main source Each which ranging as low as 40 degrees and as high 176 80 Model BP 62 contains two 2 batteries order batteries are generally designed by major As the manufacturers improve the design of batteries the amp hour rating may change the dimensions of the batteries will remain the to ensure proper fit in the system enclosures as Model BP 62 is required for use in Marine and should only be connected when each is commissioned Cover Plate XTRI Series Devices USCG XPLATE is a metal cover faceplate used in applications When Siemens XTRI Series interface are used the plate is then required for use and fitted over each device protecting it from excessive RFI size 12.7 cm H 12.7 cm W 0.6 cm D weight oz 99.2 g Model Desigo System Components Interface Unit Operating Interface Unit Model FCM2018 U2 or FCM2019 U2 functions as the operating interface central microprocessor for Model FC2025 and control panels operating interface unit offers multi use capability the end user to promptly events to control the NACs of the FACP and to reset the panel manually data relative to the nature and location of events also be displayed via a backlit 2 5.1 cm x 4.75 cm LCD screen and the four way navigation push at the top of the FACP For applications in Canada that require a Desigo unit with LEDs Model FCM2035 U2 must be 504 point addressable FACPs Boards periphery boards Models FCI2016 U1 and FCI2017 serve as the main operating components for Desigo Each module and monitors input device identity as well as with smoke detectors and other field i e C NET Supply system functions are powered internally from the power supply Model FP2011 U1 which is housed the Marine enclosure FH 2071 UM Each power provides primary 24VDC nominal power for system functionality to the Desigo 252 point panel Model FC2025 and the 504 point panel Model FC2050 170 Watt power supply incorporates a 4.0A non slow blow fuse on the primary input and a built in AC line filter for surge and noise Model FP2011 U1 mounts in the panel and there are no serviceable parts to be Model FP2011 U1 is filtered and regulated is rated at 6.5Amps Desigo Optional Accessories Module SafeDLINK network module Model FN2001 U1 is to network 16 FACPs or fire terminals via the FCnet bus Model FN2001 U1 the Operating Unit Models FCM2018 U2 R2 or Operating Unit with LEDs Models FCM2019 U2 R2 plugged FN2001 U1 which connects to system input bus has ground fault monitoring as well as an degrade mode feature Redundant networking accomplished with one 1 network module per panel Loop Trouble Electrical isolation exists between system bus and the FACP Infrastructure Building Products usa siemens com fire

Related Files