Siemens FC922, FC924 Cerberus PRO Addressable (FIRE-Only) Control Panel, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Cerberus PRO and 504 Point Addressable Alarm Control Panel FC922 I FC924 Architect Engineer Specifications Addressable fire alarm control panel FACP for mid size building applications Product Overview Comprised of the following system Operating units boards supplies enclosures Test System features 252 to 504 addressable devices One 1 to four 4 B one 1 to two A for Model FC922 One 1 to eight 8 B one 1 to four A for Model FC924 10,000 event history logging capability Includes one 1 A or two 2 B appliance circuits NACs Resettable and non resettable 24VDC auxiliary power Connectivity to a leased line city tie module Releasing module supports activation of valves in pre action deluge systems release Off normal warning message prior to reset Fast and easy set up with auto configuration Web Networkable up to 32 panels using SafeDLink Cerberus DMS Danger Management Station monitor and control up to 32 Models FC922 FC924 FACPs Supports multiple global displays Digital alarm communication transmitter UL 864 10th Edition Listed ULC S527 Listed FM CSFM NYC Fire Department Approved Cerberus PRO 252 point Model FC922 504 point Model FC924 FACP is designed to meet the fire protection needs of mid size This advanced FACP offers features typically required in mid size in a package that is easy to install and competitively priced Models FC922 and FC924 are networkable allowing the to fulfill the growing fire protection needs of the building The software for the 252 504 point fire systems is held in flash erasable programmable read only memory EEPROM following Cerberus PRO system components used in the 252 point 504 point FACP units boards supplies enclosures options are available to meet specific needs FC922 and FC924 are FM 3010 and FDNY 6104 Model FC922 Specifications Interface Unit Operating Interface Unit Model FCM2018 U3 or Model FCM2019 U3 as the operating interface and central microprocessor for Models and FC924 with up to 10,000 event history log operating interface unit provides multi use capability for each end to efficiently events to quickly control the NACs of the and to permit a manual reset of the respective system Detailed data the nature and location of the events can also be displayed via a 2 4 3 4 5.1 cm 12.1 cm LCD screen and the four way push button at the top of the FACP For applications in Canada that require a Desigo operating unit with Model FCM2035 U3 must be ordered Boards periphery boards Models FCI2016 U1 and FCI2017 U1 serve as the operating components for the 252 504 point FACP Each module and monitors input device identity as well as controls the circuits that communicate with smoke detectors and other devices i e Infrastructure Building Products Sheet 9815 usa siemens com fire Specifications cont Supplies functions are supported by the power supplies Model or Model FP2012 U1 which therefore eliminate need for external power supplies the 170 Watt power supply Model FP2011 U1 and power supply Model FP2012 U1 provide primary nominal power for normal operation to Models and FC924 Both power supplies are filtered and Model FP2011 U1 is rated at 6.5 Amps and the for Model FP2012 U1 is 11.5A 170 Watt power supply incorporates a 4.0A non slow blow fuse on the primary input and includes built in AC line filter for surge and noise suppression FP2011 U1 mounts in the FACP enclosure and there no serviceable Cerberus PRO parts to be maintained 300 Watt power supply incorporates two 2 6.3A non resettable slow blow fuses on the primary and includes a built in AC line filter for surge and noise Model FP2012 U1 mounts the FACP and there are no serviceable Cerberus PRO parts be maintained Enclosures Cerberus PRO fire alarm enclosures and their accessories a complete set of hardware for mounting all PRO main system and remote terminal cards and hardware allows this Cerberus PRO system to be for a variety of applications as well as for future upgrades Included in the enclosure series are back and door sets removable mounting plates and clear as well as blank plates for use with the enclosure enclosures come with ground straps for the inner and doors shield termination lugs grounding lugs and tie lances for securing wire All Cerberus PRO two height 2HU enclosures can also mount system back up to 33AH in capacity FC922 and FC924 utilize a The following components comprise a complete enclosure One 1 back box Model FHB2002 U1 R1 One 1 or two 2 inner doors Models FHD2004 U1 One 1 outer door Model FHD2002 U3 R3 or One 1 or two 2 clear windows Model FHD2006 FHD2005 U1 R3 approximate size for each two height unit enclosure is 70cm high 21.5 54.6cm wide and 5.75 deep The weight without any attached is approximately 6.3 Lbs 2858 g One 1 window is installed for Model FHD2002 R3 outer door and two 2 windows are required for FHD2003 U3 R3 the two height unit enclosure supports the optional components DIN rail kit provides connection between internal trim kit for flush mounting bracket to comply with seismic certification wiring and field wiring module Accessories Alarm Communication Transmitter DACT DACT is used to provide communication between FC922 and FC924 and with either a central or monitoring station The Model FCA2015 U1 module directly on the back enclosure and connects to the boards The DACT enables remote transmission of and events via a public telephone line Module XCI2001 U1 supports of releasing valves in pre action deluge systems double interlock pre action systems or Sinorix Fire Suppression systems Activation can be or performed by addressable manual pull The releasing module is installed on the periphery and supports Class B releasing circuits installed on Models FC922 FC924 the releasing contains an integral manual disconnect switch for circuits This essential protects the accidental discharge during City Tie Module Leased Line City Tie module Model FCI2020 U1 is as an optional module providing a local energy output municipal call box connection FCI2020 U1 also gives a reverse polarity output for connection Model FCI2020 U1 is installed on periphery board for Models FC2025 and FC2050 FACPs used for connection to a municipal call box the city function supports Alarm event transmission When used leased line connection the module supports two 2 telephone lines for transmitting Alarm Trouble and events Disconnect Module Battery Disconnect Module Model FCA2032 U1 is designed to disconnect the backup battery on Cerberus PRO 252 504 point addressable FACP when its drops below 19VDC Model FCA2032 U1 cut off prevents the battery from operating beyond it

Related Files