Siemens FCM-6, LCM-8, SCM-8 (for FireFinder) Control Modules, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s XLS Module LED Control Module Fan Control Module SCM 8 LCM 8 and FCM 6 Eight 8 programmable switches Model SCM 8 Protected space provided for labeling Discreet switches Multi color LEDs for clear indication of system status Modular Programmable LED annunciation Remote mounting in REMBOX2 or REMBOX4 enclosures Six 6 sets of the push button fan control switches FCM 6 Manual positions Positive feedback supervised LED indication of fan status Protected label provided Modular Activation stagger timer UL 864 9th Edition Listed ULC Listed FM CSFM NYMEA Approved Overview SCM 8 is a Siemens FireFinder XLS option that provides manual control of the Voice Evacuation System or Manual Control Each Model SCM 8 module eight 8 momentary push button and 16 LEDs to indicate their status Each is assigned two 2 LEDs and a label to the switch s programmed usage The label behind a clear protective membrane Industry Inc Technologies Division of the LEDs assigned to each switch is a dual LED used to indicate what type of signal is This LED may also be lighted steady or to further indicate system status example zones active to the evacuation audio will have the LED lighted RED and steady active to the Alert audio channel will have LED lighted RED and flashing zones selected paging will have the LED lighted GREEN and until the microphone key is pressed XLS 6317 Overview continued the zone transfer confirmation message is by the XLS command console the LED will to steady GREEN indicating that it is clear to Telephone zones with an incoming call in will have an LED flashing GREEN until at the command console at which time the will change to steady GREEN etc This process the operator easy clear access to the overall condition at all times The second LED is and is used to indicate a fault condition Model SCM 8 module and each switch is fully and may be used to control speaker and a wide range of general system functions as All Call All Evac Warden s Page Speaker Any number of circuits may be grouped and by a single switch Switch usage and zone are assigned using the ZEUS system software Model SCM 8 module is mounted on a hinged as a part of the FireFinder XLS command enclosure LCM 8 is a FireFinder XLS option module that LED annunciation of system activity Each LCM 8 module contains eight 8 groups of 2 LEDs each of which can be assigned to outputs using the ZEUS programming Eight 8 LEDs are capable of being lighted RED or GREEN flashing or steady The LEDs are AMBER flashing or steady space is provided for labeling of LED functions The slides behind a clear protective membrane LCM 8 dimensions are identical to Model SCM and Model LCM 8 is mounted on the same hinged as a part of the FireFinder XLS command enclosure Any combination of Models SCM and LCM 8 modules may be used FCM 6 is a FireFinder XLS command option module that provides manual of building HVAC system fans and Each Model FCM 6 module provides six sets of three 3 push button switches for system control Each switch has three 3 LEDs to indicate Fan Damper status Red LED Green LED LED Industry Inc Technologies Division in the automatic position the red and green indicate Fan Damper status based the system logic that can be programmed to control the fan outputs When switched to the position the red LED flash indicating the output circuit used to turn the Fan Damper has activated The red LED will a steady stream of red to indicate positive of the Fan Damper actually turning off a monitored input When manually switched the position the green LED will flash the output circuit used to turn on the Damper has activated The green LED will to a steady green to indicate positive feedback the Fan Damper actually turning on via a input system reset when switches have been set to the or the position their outputs do not change state The stay either or based on the of the switch will only change state when manually via the switch or based on logic when switch is in the position Model FCM 6 module is mounted on a hinged as a part of the FireFinder XLS command enclosure Any combination of Model SCM Model LCM 8 or Model FCM 6 modules may be on the inner door mounting plate Model A six conductor cable is supplied for of the modules A 30 inch cable CCL is available for connection between SCM 8 LCM 8 and FCM 6 may be remotely up to 1,000 feet from the main enclosure and REMBOX4 lobby enclosures are for remote mounting of Models SCM 8 and FCM 6 The CAN sounder board Model is optionally available for audible feedback for mounting applications Ratings for Ordering and Humidity Range are UL 864 9th Edition listed for indoor locations within a temperature range of 49 2 to 32 3 0 2 and at relative humidity of 93 2 at a temperature of 32 2 Diagram Diagram FCM 6 LCM 8 SCM 8 Modules the CSB Industry Inc Technologies Division This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 in U S A 2010 sheet dated 7 09 2

Related Files