Siemens FSD901-U2 FSD901-R2 FSD901-U3 FSD901-R3 Floor Repeater Display, Product Manual

File Preview
File Preview
Click below to download for free

Text Preview

FSD901 U2 FSD901 R2 FSD901 U3 FSD901 R3 Repeater Display Manual floor repeater display is an indication and operation unit in a fire detection system the following functions of events Alarm Trouble Supervisory Status Scrolling through lists Reset Acknowledge Unsilence Silence display on the floor repeater terminal is synchronized with the fire control panel and the same event texts Small floor repeater operating and display panels applied in FC2005 FC901 fire system Large backlight LCD display 160X64 Communication with controller via RS485 individual addressing Additional 24 VDC power supply necessary In total up to 8 FSD can be connected to a fire control panel Access control by key Flat elegant housing Infrastructure Display of alarms troubles supervisory and status event Same message layout as the fire control panel With the navigation keys an indicated list in the display can be scrolled through The internal buzzer can be switched off manually by pressing button Reset events displayed on the FSD Silence and unsilence Level Front view Name button Fault on of alarms troubles supervisory and status up in case of fire menu navigation up when power supply is normal up in case of trouble event up in case of ground fault event activated silenceable devices are silenced up in case of supervisory event up when NAC or silenceable device is activated all events unacknowledged events silenced devices are activated again all activated silenceable devices user access level by key floor repeater display control access right through lock on door There are two levels for access right level key position operation items for L0 L1 are listed as below real time events test and Baud Rate Resistor real time events test or reset devices devices Press to navigate a real time event Press to return to first event both Silence and Unsilence button for 5s to do test Acknowledge or RESET Unsilence all silenced devices are activated again Silence silence all activated silenceable devices Dip switch S1 is used for setting the FSD901 address and Baud Rate Setting first 1 4 digits is for setting the FSD901 address 1 8 the 7 8 digits is for setting communication baud rate The 5 and 6 digits are reserved for future use switch Rate bps bps bps bps switch and FC901 can only support 19200 bps other options reserve for future usage Dip switch S20 is used for setting EOL resistor of RS485 and 2 and 2 RS485 Class A loop mode no EOL resistor is needed RS485 Class B stub mode internal EOL resistor of the repeater display at the end RS485 must be connected EOL resistor is connected EOL resistor is disconnected 2 Dimension mm 3 Connection G is not used for any connection in from the non resettable auxiliary power output on 4 5 Insert the loop line and external power wire through the floor repeater display Mark the position for the 4 installation holes on flat wall Fig 2 drill the holes put expansion bolts in and insert the leaving a small gap for hanging the display Hang the floor repeater display over those screws through installation holes Open the front panel Fig 4 5 tighten the screws and make sure the display is fixed firmly Connect cables to terminals referring to the connection diagram Fig 3 Correctly set the internal 120 EOL referring to the section Resistor Close the front panel connects to separate power supply which needs to be UL Listed for Fire Safety Use and Power mm data for ordering No by Industry Inc Infrastructure Fernwood Road Park NJ 08932 1 973 593 2600 No voltage current quiescent current temperature protocol terminals location VDC nominal 19 VDC mA mA rel AWG Red dry RS485 BUS No system display black system display red system display bl system display red kg kg kg kg Siemens Industry Inc 2019 specifications and availability subject to change without notice

Related Files