Siemens HMS-D, HMS-DZ HMS-S, HMS-SZ HMS-Series Intelligent Initiating Devices, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Initiating Devices HMS D I HMS S I HMS DZ I HMS SZ Architect Engineer Specifications Durable metal design and vibration resistant Product Overview Siemens intelligent manual fire alarm boxes Models HMS S HMS SZ and HMS DZ provide the most advanced method of address programming and Model HMS series manual box achieves the state of an by incorporating custom microcomputer chip technology with sophisticated communication capabilities with the panel which include Siemens as well as Siemens 50 point 252 point and 504 point addressable FACPs Model HMS series manual fire alarm boxes are also included in US Coast Guard approval for use in marine and other harsh environments when used with Siemens 252 point and 504 point USCG approved addressable system Model HMS S SZ and Model HMS D DZ lever is down until reset with Allen Key break rods necessary microcomputer chip insensitive via SureWireTM Dynamic supervision to the fire control panel FACP or semi flush installation programming is easier as well as more dependable DPU programs and address and of each device Americans with Disabilities Act ADA UL Listed Fire Dept 202 12E Vol 1 7150 0067 0036 and 161.002 60 0 3015946 3052621 Specifications HMS S HMS SZ and HMS D HMS DZ are of durable molded polycarbonate that is matte finished in red with raised lettering The housing accommodates a lever which when operated locks into indicating the fire alarm box has been pull down lever remains down in the until the fire alarm box is manually reset manual fire alarm box can only be reset by the hinged housing cover with an Allen key by closing and locking the cover Models SZ and HMS D DZ operate with Siemens Safety FACPs The microcomputer chip to the fire alarm box has the capacity of storing memory identification and important operating data HMS S SZ and HMS D DZ are fitted with terminals for connection to an addressable and can be either surface or semi flush Model HMS series manual fire alarm boxes their power communicate information and commands over a single pair of wires Each is compatible on the same circuit with all Model detectors or addressable zone modules HMS D DZ Station HMS S SZ Station Infrastructure Building Products Data Sheet 6306 usa siemens com fire Diagram Device Programmer Tester Model DPU technology from Siemens Fire Safety also allows all Model HMS series intelligent manual fire alarm boxes to be via the Device Programmer Test Unit Model DPU The programmer tester is a compact portable and menu accessory that makes programming and testing of a manual fire alarm box device faster easier and more dependable previous methods DPU eliminates the need for mechanical addressing mechanisms of a device because Model DPU electronically sets the of the manual fire alarm box into its microcomputer chip non volatile memory Therefore vibration corrosion and conditions which can compromise the functionality of mechanical addressing mechanisms are no longer an issue Technical Data Draw or Standby Manual Fire Box Dual Action DRY CONDITIONS S54321 F5 A1 Manual Fire Box Dual Action USA Lbs 1.13 0z Range 100 38 93 Range Manual Fire Box Single Action S54321 F6 A1 Manual Fire Box Single Action Lbs 0.9 0z Lb 0.23 0z Box Lbs 0.7 0z USA Tool Package two 2 tools denotes C ountry O f O rigin Details for Ordering firealarmresources com NOTICE The information contained in this data sheet document is intended as a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Warning and Limitations document which also contains data are provided with the product All are available the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 2019 10

Related Files