Siemens LED Series Remote Annunciators, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-led-series-remote-annunciators-data-sheet-8605923471.pdf |
---|---|
Type | |
Size | 1.15 MB |
Downloads |
Text Preview
LED Series Annunciators for SXL SXL EX and PXL LED 3 and LED 4 8 Zone LED Display Annunciates Zone Alarms Supervisory Trouble Conditions Surface or Semi flush Installation 4 Wire Connection SXL SXL EX and PXL Field Programmable Up to 2 Remote Annunciator Banks SXL SXL EX or PXL ULC Listed CSFM NYMEA FM Approved Building Technologies Fire Safety Division LED Annunciators are designed to be used with SXL SXL EX or PXL Fire Alarm Control Panels are eight point annunciators containing sixteen for the display of alarm supervisory or trouble by zone LED can be located in the building lobby or in a area In its quiescent mode of operation all are off In the event of an alarm a red LED will light indicate which device or zone is in alarm To report i e removal of a detector head the corre yellow LED will light Supervisory conditions annunciated by the corresponding amber zone LED left most LED is a bi color device which illuminates for zone alarm conditions and amber for supervisory The Remote Annunciator may be tested by using Lamp Test feature in the SXL SXL EX or PXL test perform the important service of pinpointing location of the alarm device or the zone from which alarm originates and Architect Specifications LED annunciators will have LED for Alarm and Trouble conditions per zone There will be zones per annunciator It shall be connected to the SXL EX or PXL auxiliary port The annunciator be addressable via DIP switches The remote shall be Fire Safety model LED 3 LED 4 actuation of an initiating zone the corresponding LED will light red Each additional zone will light its corresponding LED a supervisory circuit changes state to off normal alarm supervisory LED will light amber When an circuit goes into trouble the yellow zone trouble will light The Remote Annunciator can be tested the Lamp Test feature of the Control Panel to proper functioning of the LEDs NUMBER Information annunciators are field programmable at the time of The dipswitch address must be set and the configured for use of the LED via the program in the control panel Please see the Installation P N 315 093066 for further information on and installation and Environmental Power Current VDC Alarm LEDs only All LEDs lit to 49 non condensing 1 4 H x 3 5 8 W x 1 1 16 D oz gang electrical box Temperature Humidity Diagram UL listed SXL EX Panel AUX TB 3 Non Limited listed PXL Panel TB 5 Limited The use of other than Fire Safety detectors and bases with Fire Safety control equipment be considered a misapplication of Fire Safety equipment and as such void all warranties either or implied with regards to loss damage liabilities and or service problems Building Technologies Safety Safety Fernwood Road Park NJ 07932 973 593 2600 973 593 6670 www sbt siemens com fis in U S A Safety Kenview Boulevard Ontario L6T 5E4 905 799 9937 905 799 9858 2003 sheet dated 6 00