Siemens MKB-5 MKB-5C Annunciator Keypad Module, Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-mkb-5-mkb-5c-annunciator-keypad-module-installation-instructions-9210846375.pdf |
---|---|
Type | |
Size | 1.03 MB |
Downloads |
Text Preview
Installation Instructions MKB 5 5C Module Model MKB 5 5C Annunciator from Siemens Inc communicates with the MMB Main Board through the System network link The provides the MXL with its primary control annunciation MKB 5 5C has a multi line display that continu updates information about the system event If there are multiple events alarms security supervisories and or troubles the highest event that occurred displays on the screen The can view up to 8 events at a time and can scroll the complete list using the Up and Down on the operation of the MXL Multi Line Panel refer to the MXL Keyboard Panel Operating Instructions P N 315 048692 Section 3 OPERATION in the MXL MXLV P N 315 092036 keys located next to the More Info key For further keyboard display panel has keys for the following Acknowledging fire alarms ALARM ACK Silencing audibles AUD SIL Acknowledging supervisories SUPV ACK Acknowledging troubles TRBL ACK Acknowledging security conditions SEC ACK is also a separate key for resetting the Control RESET 10 digit numeric keypad allows entry of the three of user passwords It is also used to perform menu driven operations as well as pro and maintenance functions UP and DOWN keys located next to the INFO key allow the user to scroll forward and through the entire list of events SPACE key allows the user to input addresses by enabling them to reduce redundant key of the key MORE INFO key allows the user to instantly view relevant information about the highlighted event is displayed in the last three lines of the screen user can access the MXL Control menu by the ENTER key panel has System status indicator LEDs The and TROUBLE LEDs function even if the processor fails See Figure 1 1 2 SYSTEM 1 Panel Industry Inc Technologies Division Park NJ 315 048727 5 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada all system power before installation battery and then AC To power up connect AC first then the battery the MKB 5 5C Inspect the module for such as integrated circuits ICs not firmly seated in sockets bent IC pins connectors not properly dirt and packing material on the board MKB 5 5C is supplied with the keyboard annun mounted to the hinged panel but with black filler installed to the right and left to accommodate a and microphone if used To install the module TMM 1 or microphone module on the MKB 5 5C follow the installation which accompany those modules P N and P N 315 092099 respectively To the TMM 1 module when using an MMB 3 it is to first remove the ANN 3 board on the of the MKB 5 After the TMM 1 is mounted the can then be replaced the Network Address the Network Address for the MKB 5 5C using the ten position rotary switches S1 S2 and S3 on the back of the keyboard display panel as in Figure 2 For example to set the switches to 248 set S1 to 2 set S2 to 4 and set S3 to 8 possible addresses for this module are 248 249 and 251 There is no need to set supervision on the because it is by default always No unsupervised annunciators are allowed at the same as an MKB 5 5C Unsupervised require the use of the MKB 1 and they must all be set to the same 3 3 3 J5 2 3 4 5 2 3 4 5 OPTION OPTION 2 Rear View the MKB 5 5C to Figure 3 four screws in the first group of four tapped in the right flange Leave a 1 8 inch gap the head of the screw and the flange the slots of the MKB 5 5C panel hinge the head of the screws and tighten the panel locking fastener is not aligned with the located on the left flange loosen the screws adjust accordingly Retighten the screws 3 the MKB 5 5C to Figures 4 5 and 6 Pull all field wiring into the backbox and dress the to the approximate location to which it will go 3 3 3 Remove the connector plugs from J8 Attach the to the connector plugs in positions 1 and 2 for 4 and positions 1 2 3 and 4 for Style 7 Always position 5 to Chassis GND Earth GND Remove the connector plugs from J12 Attach the wiring to the connector plugs making sure position 1 on J12 is for 24VDC and position on J12 is for 24VDC return needed J11 is the connector for a parallel and J10 is the connector for a serial printer serial connection can be supervised the connection is supervised by default Note only one printer either parallel or serial may connected to the system for the MKB 5 5C printer is set in In the Network Module Map select the and press Enter Scroll down to Printer and press Enter to toggle to the correct The fields Supervised Operation and Serial must both be set to YES RATINGS Make certain the connector plugs are in place on for normal operation and network programming Using 8 wire ribbon cable P N 555 148722 connect on the back of the MKB 5 5C to P6 on the or to P7 or P10 on the MOM or to P3 or P4 the OMM Make sure that the red tracing wire is position 1 on both connectors the MKB 5 5C is used with an MXLV system P5 on the ACM 1 to P8 on the MMB 2 3 Refer to MMB 3 Installation Instructions 315 048860 Configuration and MNET to configure the MMB 3 and CSGM for 4 7 wiring to the MXL Multi Line Display Panel Operating P N 315 048692 for additional information the operation of the keyboard panel adjust the contrast and brightness of the display pots VR1 and VR2 respectively located on the of the keyboard display panel Refer to Figure 2 And RDM 1 Wiring To MKB 5 6 Or RCC 3 or RDM 1 C Wiring To MKB 5 6 Or RCC 3 PORT a minimum wire gauge 22 AWG a maximum of 80 ohms pair of wires for the connections shielded twisted pair for connections the shield ONLY the MMB enclosure MMB 1 2 3 Style 4 use 120 Ohm 1 4W 5 P N 140 820150 in 1 and 2 on plug J8 configuration is power to NFPA 70 according NEC 760 MUST be an earth connected to the Wire shield or is not an acceptable Use any available unpainted stud on MMB for chassis to Wiring Specification MXL MXL IQ and MXLV P N 315 092772 6 or higher for wiring information Maximum voltage 8V peak to peak current 150mA 4 Style 4 Wiring a minimum wire gauge of AWG a maximum of 80 ohms pair of wires for the network shielded twisted pair for connections the shield ONLY at MMB enclosure Style 7 use a 120 Ohm 5 EOLR P N 140 in positions 1 and 2 and 3 and 4 on plug J8 Style 7 use a NET 7 card r