Siemens MLC (for FireFinder) Line Card, Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name siemens-mlc-for-firefinder-line-card-data-sheet-5186742903.pdf
Type PDF
Size 905.49 KB
Downloads

Text Preview

Sheet Safety Security Products XLS Line Card MLC AND ENGINEER SPECIFICATIONS Alarm Trouble Supervisory Security and Status reporting Two 2 intelligent analog device circuits 60 intelligent devices per circuit Accepts remote conventional zone modules Degrade mode Supports audible bases On board microprocessor On Board ground fault detection Programmable Input Output module Short circuit isolation with Model LIM 1 Remote smoke detector sensitivity adjustor Independent control of detector relays Up to 60 relays per circuit Intelligent contact monitoring devices B Style 4 or A Style 6 wiring position Supports T Tap wiring for B circuits MLC View MLC View UL 864 9th Edition Listed Approved Overview MXL Line Card Model MLC is an optional card the FireFinder XLS fire alarm control panel FACP supplies two 2 intelligent analog circuits the Model Model ID Model or Model FP type intelligent devices MLC occupies two 2 addresses on the HNET and through the use of a unique protocol devices connected the Model MLC circuits are dynamically by FireFinder XLS detectors are monitored for sensitivity and notification is given when the obscuration is outside normal parameters of the Model MLC circuits supports the use up to 60 Alarm Trouble security status and devices Further remote initiating device zone modules Model intelligent monitoring devices Model TRI intelligent control points Model ICP B6 are also by Model MLC circuits continued of certain smoke detectors can be queried and at the FireFinder XLS control panel Further obscuration as well as other device can be displayed and printed at the XLS MLC supports the use of relay bases and audible bases controllable To provide analog loop short isolation the Model LIM 1 module can be used to a single short circuit from interrupting loop device Model MLC circuit can be wired in either a B 4 or A Style 6 configuration When using Style 4 method T Tap wiring is permitted with no loss supervision MLC has an on board microprocessor which provides ability to function in a degrade mode and initiate alarm even if the FireFinder XLS main central unit CPU fails Model MLC plugs into one 1 slot in the Model CC 5 or Model CC 2 card cage Line Card for FireFinder XLS 6354 Industry Inc Technologies Division and Humidity Range MLC is UL 864 9th Edition Listed for indoor locations within a temperature range of 49 2 to 32 3 0 2 and relative humidity of 93 2 at a temperature 90 3 32 2 Documentation XLS Overview Sheet Number for Ordering MXL Addressable Line Card for FireFinder XLS This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2012 sheet dated 2 12 2

Related Files