Siemens MME-3 (R) Enclosure, Installation and Power Limited Wiring Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-mme-3-r-enclosure-installation-and-power-limited-wiring-instructions-8319645072.pdf |
---|---|
Type | |
Size | 896.80 KB |
Downloads |
Text Preview
Installation and Power Limited Wiring Instructions MME 3 R for the MXL MXLV Control Panel MME 3 R from Siemens Industry Inc a medium size enclosure for the MXL MXLV The enclosure consists of a backbox front door that is shipped assembled Note the backbox has a flanged lip to permit mounting in addition to the usual mounting The MME 3 is black and the is red they are identical in all other the following when mounting the Mounting height for visual and manual to the MKB 2 Keyboard annunciator Weight and size of enclosure Local mounting codes the backbox securely to a clean dry and vibration free surface MME 3 is for indoor use only in dry environ Position the backbox clear of obstruc so that the front door opens freely and so the indicators and controls are easily When the backbox is mounted semi be sure that the position of the permits the front door to fully open install the MME 3 backbox to Figure 1 1 the Backbox Hold the empty backbox against the wall at a that provides easy access Mark drill points on the wall in the center of the slots on the upper rear of the backbox Drill the two holes and screw in the top bolts a small gap between the wall and top bolt Mount the backbox on the two bolts and then the bottom bolts in the two holes provided Slip the front door off the hinges of the box Tighten all bolts securely against the back put it to one side temporarily of the backbox Remove the knockouts in the backbox Slip the front door back on the hinges of the field wiring is required See Figure 2 Industry Inc Technologies Division Park NJ 315 094883 6 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada Door 2 the Front Door DOOR front door is the main outer door for MME 3 enclosure The door is sup without filler plates for the two large To select the appropriate filler for the two openings follow the below When visual indication of system LCD LED or printer is install clear panels the lens behind the appropriate openings When visual indication of the sys operation is not required install blank panels MDB 1s behind the door openings When audio amplifiers such as the or ZAC 30 are used install MDG 1 MXL Door Venting Grill the appropriate door openings the Filler Plates in the Front Door 3 After determining which filler plates are insert the appropriate plates in front door as shown in Figure 3 using hardware supplied PLATE MBR MP the MBR MP Mounting Plate which is separately Refer to the MBR MP Installa Instructions P N 315 094882 compliance with UL 864 effective May 1 all power limited fire protective signaling must be separated a minimum of 1 4 from all of the following items located within control panel electric light power Class 1 or non power limited fire protective conductors meet the above requirements the following must be observed when installing and wiring to this control panel If power limited wiring is not used within MXL MXLV enclosure then the guidelines do not apply In that be sure to follow standard wiring ENTERING MAIN ENCLOSURE Limited Wiring to the following MXL MXLV module is considered non power limited and enter the enclosure through the knockouts in Table 1 Refer to Figure 4 Wiring the knockouts specified and the module must be in the shortest route and not overlap any other wiring 1 from EL 410C D Zone Cards from EL 410C D OMM 1 MOM 4 MOM 4 1 2 3 1 2 3 OMM 1 or 10 or 10 or 10 or 10 CRM 4 CSM 4 modules must be installed in the left MOM module position Install the first in position A the second in position B etc as in Figure 4 When the CSM 4 is used as Municipal Tie or Service Audio or strobe power wiring to any ZC Zone Card and ASC 1 2 first must be terminated at a plug in module installed in an OMM 1 and at the zone card The PLC 4 must contain at one of the following plug on boards a PL864 or PL864 70A for audio circuits or a PL 864 for strobe circuits Refer to the PLC 4 Instructions P N 315 093312 there are no MOM 4 CRM 4s installed in the install the PLC 4 in the extreme left module position in connector position B second in position L as shown in Figure 6 there are MOM 4 CRM 4s installed in the install the OMM 1 in the next available position Install the PLC 4 as shown in 7 Wire between the PLC 4 and the zone card in accordance with the accompanying these modules IN MAIN ENCLOSURE Limited Wiring following wiring is considered non power the MPS 6 W or MPS 12 W the batteries to the MMB the MMB P3 to the MOM 4 P5 maintain the required separation the wires be routed and held in place by a separate support This support is positioned on the side wall of the enclosure as shown in Figure Follow the procedure listed below Locate the wire standoffs mounted on the left of the enclosure See Figure 5 Place the wires in the standoffs close the and then route the wires to the appro terminations as shown in Figure 5 When the TSP 40 optional printer is used printer cable to the MOM 4 P8 is to be non power limited Route cable as shown in Figure 4 ENTERING MAIN ENCLOSURE Limited Wiring to the following MXL module terminations considered power limited and must enter the through the knockouts specified in 3 from EL 410C D Zone Cards from EL 410C D OMM 1 MOM 4 MOM 4 1 2 3 1 2 3 OMM 1 or 10 or 10 or 10 or 10 CRM 4 modules must be installed in the extreme left module position Install the first CRM in A the second in position B etc as shown Figure 9 When the CSM 4 is used as Municipal Tie or Service Audio or strobe power wiring to any ZC Zone Card and ASC 1 2 first must be terminated at a plug in module installed in an OMM 1 and at the zone card The PLC 4 must contain at one of the following plug on boards a PL864 or PL864 70A for audio circuits or a PL 864 for strobe circuits Refer to the PLC 4 Instructions P N 315 093312 there are no MOM 4 CRM 4s installed in the install the PLC 4 in the extreme left module position in connector position B second in position L as shown in Figure 6 there are MOM 4 CRM 4s installed in the install the OMM 1 in the next available position Install the PLC 4 as shown in 7 Wire between the PLC 4 and the appro zone card in accordance with the instruc accompanying these modules IN THE REMOTE ENCLOSURE Limited Wiring following wiring is considered non power from the MPS 6 W or MPS 12 W from the batteries to the PSR 1 2 Refer to Figure 4 These modules must installed in the extreme right MOM module three MOM 4s are used in the system install first module in position M the second in L etc as shown in Figure 5 Wiring the knockouts specified and the module must be in the shortest route and not overlap any other wiring Module Termination 2 MOM 4 MOM 4 MOM 4 MOM 4 MOM 4 TB1 1 4 TB2 1 4 TB3 1 4 TB4 1 9 TB5 1 12 MOM 4 TB1 TB1 1 6 OMM 1 MOM 4 TB4 All positions TB5 All positions MOM 4 OMM 1 OMM 1 ALD 2 ALD 2I CMI 300 CSM 4 CZM 4 MMB NET 4 7 NIM 1R PIM 1 PS 5N7 OCC 1 REP 1 TBM 1 2 XLD 1 ZAC 30 ZCT 8B or 7 or 7 or 7 or 7 or 7 or 4 or 4 or 7 or 4 or 4 or 7 or 7 or 4 or 4 or 7 or 7 or 7 When the CSM 4 is used as Notification Applica Circuit or Leased Line Listed Class 2 or Power Limited Source ENTERING THE REMOTE