Siemens MXL to Cerberus PRO Compact Systems Migration Hardware Kit, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

PRO Compact Device Interface Module FCL2004 U1 Migration Hardware Kit FHA MIQKIT 04 FHA MIQKIT 05 Architect Engineer Specifications Introduction provides migration options for MXL IQ or MXL systems to Cerberus PRO Systems FC922 924 The MXL Device Interface Module allows MXL addressable devices onto existing MXL IQ or MXL systems to connect Cerberus PRO Compact panels The MXL IQ Migration Hardware Kit allows conversion of an MXL IQ to a Cerberus Compact system keeping the back box wiring and conduit in place Product Overview Device Interface Module Model FCL2004 U1 loop driver is a module that allows MXL intelligent smoke detectors manual stations monitors and control devices to to the Cerberus PRO 252 Point and 504 Point Addressable Control Models FC922 and FC924 application program loaded into the on board microprocessor controls the operation A fully operational Cerberus PRO fire alarm control panel can support a maximum of 240 MXL intelligent field devices using up to 2 FCL2004 modules inside the enclosure FCL2004 U1 contains one reset switch for the main processor and seven diagnostic LEDs Ground fault detection of the intelligent loops is also field devices connected to the FCL2004 module are addressed and tested the Device Programming Unit DPU or the FPI 21 Programmer Tester The system setting on the DPU and FPI 32 must be set to the MXL Device Module MXL Device Interface Module FCL2004 Supports Two 2 intelligent device circuits up to 60 intelligent devices per circuit One 1 Reset switch for the main processor and 7 diagnostic LEDs Capability to report Power I Alarm I Trouble conditions Option to convert existing MXL CSGM to new Cerberus PRO On board microprocessor Ground fault detection Programmable Input Output module Supports relay bases audible bases remote UL864 9th Edition Listed ULC S527 3rd Edition USCG Approval pending MXL IQ Migration Hardware Kit Migration of panel hardware into a Cerberus PRO panel Fire only panel for up to 252 addressable Fire only panel for up to 504 addressable Model FC922 Model FC924 Replacement of internal system electronics of Siemens legacy MXL IQ control panel Each new migration hardware includes the equipment one 1 outer door one 1 inner door one 1 back plate Re use of existing panel back box No need to replace existing conduit and wire Orderable with either black or red outer door Migration hardware functions with optional Model FCL 2004 PRO modules Digital Alarm Communication Transmitter FCA2015 U1 Releasing module XCI2001 U1 NAC expansion module FCI2011 U1 Line City Tie Module FCI2020 U1 Suitable for use with the following MXL IQ MSE 3 3R MSE 3L 3LR UL864 9th Edition Listed ULC S527 3rd Edition FCL2004 U1 MXL Device Interface Module Infrastructure Building Products Data Sheet 9827 usa siemens com fire FCL2004 U1 initializes operates and maintains all devices residing on the loop It communicates all relevant and event information such as alarms and troubles to the Cerberus PRO addressable control panel The of any intelligent input smoke detector and the logic functions of any intelligent output device can be and adjusted from the Cerberus PRO FACP All information about the devices on the loop can be displayed on Operator Interface PMI Refer to the Cerberus PRO 252 Point and 504 Point FACP Manual for information about each device on the loop the FCL2004 module is used with the Cerberus PRO 2HU enclosure or the marine approved enclosure FCL MXLPLATE mounting bracket is required The mounting will support up to two FCL2004 MXL device interface and includes necessary mounting hardware placement of the FCL2004 modules on the adapter plate its address The first FCL2004 module is always 91 and the second where applicable module is always 92 FCL2004 module supports two separate circuits of MXL intelligent field devices Each circuit can monitor and up to 60 intelligent devices as well as device accessories relay bases audible bases and remote lamps in any on board microprocessor provides the module with the ability to function and initiate alarm conditions even if the Interface PMI fails FCL MXLPLATE Mounting Bracket STATUS NORMAL Indicator Table the power for the MXL is applied to the card Indicates one of the following conditions if illuminated hardware failure on the card or unsuccessful upload is being updated through the PMI has detected an alarm a trouble is present on the card not related to its wiring or slave ALD driver card has detected a wiring trouble fault or ground fault on device loop 1 or 2 field wiring the card has detected an alarm FCL2004 U1 supports two device loops of up to 60 intelligent field devices Each loop draws a maximum of 90mA from MXL Line Card Model FCL2004 U1 circuit can be wired in either a B Style 4 or A Style 6 configuration When using the 4 method T Tap wiring is permitted with no loss of supervision remote conventional initiating device zone modules Model CZM 1B6 intelligent monitoring devices Model TRI and control points Model ICP B6 are also supported by Model FCL2004 U1 circuits MXL Compatible Devices Table on Page 3 for more information Infrastructure Building Products O COMPATIBLE DEVICES with DB ADPT or DB 11 DB X11RS ADBX 11 with DB ADPT or DB 11 DB X11RS ADBX 11 Quantity the Loop DB X3RS DB X3RS AD 3XRI DB X3RS DB X3RS duct application supports drift compensation IEC Migration Hardware Kit Overview MXL IQ Migration Hardware Kit Model FHA MIQKIT is specifically designed for the seamless transition of an existing Legacy MXL IQ Control Panel into a fully operational Cerberus PRO 252 or 504 addressable point Models FC922 and fire alarm control panels FACPs Model FHA MIQKIT series mechanical migration kit includes the following pieces of equipment one 1 outer door either Black or Red one 1 inner door one 1 back plate The three 3 items that comprise one 1 Model FHA series hardware migration kit cannot be individually FHA MIQKIT Migration Hardware

Related Files