s XLS Charger Power Termination Board Module Power Supply Extender PSC 12 PTB and PSX 12 AND ENGINEER SPECIFICATIONS Sheet Safety Products Main system power supply Total power output 12 Amp 24VDC Built in charger for up to 100AH batteries Universal AC power input 120VAC 240VAC 50 60Hz Off line switch mode power converter Filtered regulated 24VDC Mounts on back box or optional CAB MP in one 1 module space Common Alarm common Trouble relays Form rated 2A Two 2 Programmable relays Form rated 2A Provides 12 Amp non power limited 24 VDC output internal use Provides 24VDC and 6.2VDC power to all modules to a 60 pin bus 4 Amp power limited 24VDC output external use Supervised Intelligent Module with plain decimal addressing Communicates with PMI CPC via common 60 pin power data bus Ground fault detection circuitry Optional enclosure tamper switch connection point Model HTSW 1 Includes PTB Power Termination Board for AC field connections Optional 24VDC system power expansion with the power supply Model PSX 12 CSFM NYC Fire Department Approved Models PSC 12 and PSX 12 share common batteries Up to three 3 Model PSX 12s connected to Model PSC 12 UL 864 9th Edition Listed ULC Listed Overview cid 326 Model PSC 12 Model PSC 12 Power Supply Charger is a power supply that provides XLS with primary regulated 24VDC to operate at 12 Amps Alarm 5 Amps PSC 12 has a built in battery charger of charging up to 100AH batteries Industry Inc Technologies Division PSC 12 is an addressable intelligent microprocessor module that communicates its status to the interface PMI PMI is able to query the status of the power supply obtain information regarding system charging current loading information ground fault conditions and XLS Power Components 6322 Overview cid 326 continued PSC 12 PSC 12 is a universal power supply accepting power input levels from 120VAC 240VAC 60Hz No special configuration is required Model PSC 12 is designed to operate across these input ranges PSC 12 has an off line switch mode power and a power factor correction circuit to conductive RF emissions at low PSC 12 communicates with the H Net with other system cards and modules the common 60 pin power data bus PSC 12 also provides the FireFinder XLS with 6.2VDC 2Amps and 24VDC cid 326 via the 60 pin bus cid 326 to provide basic to cards and modules This 24VDC and power is also referred to as with the current the PSC provides 12Amps of power 24VDC Two separate power output terminals are one 1 power limited with 4A max capacity and one 1 non power limited with max 24VDC capacity the total not to 12A Model PSC 12 also provides two 2 points for the 60 pin power data bus 24 VDC outputs for Model PSC 12 provide auto current protection circuits for overload short circuit conditions battery sizes installed are entered in the configuration tool Model PSC 12 can 15AH 31AH 75AH or 100AH batteries The monitors and maintains the battery The has three 3 charge modes cid 326 depending the state of the batteries Bulk full Charge Trickle Charge State and Float State The charger monitors the and automatically determines which of charging modes to activate PSC 12 can charge lead acid batteries PSC 12 mounts on one 1 of four 4 available spaces directly on the back box or Model CAB MP module mounting plate then mounts inside of Models CAB 1 CAB 2 or system enclosures PSC 12 has four 4 Form relays rated at Amps each A relay is dedicated to automatically on Any System Alarm this is the Alarm Relay Another is dedicated to operate on Any System Trouble is the Common Trouble Relay Industry Inc Technologies Division 2 additional relays are available to be programmed activation based on system control logic a door tamper switch is required in any of the CAB the Model HTSW 1 tamper switch can be connected to Model PSC 12 to provide this PSC 12 has diagnostics LEDs to indicate On Failure internal module failure Failure failure Fault internal to or on any 24VDC output circuits 12A Fail 4A Fail Model PSC 12 module is addressed plain decimal address switches which clearly the address of the module an option an extender cable Model PSC ISO CBL can usage of two 2 XLS universal power supplies PSC 12 in one 1 Model CAB series enclosure PTB PSC 12 Power Termination Board comes packaged a module known as Model PTB Model PTB is the Board and is required for operation the PSC 12 Model PTB must be mounted in the corner of the CAB enclosures Mounting studs provided in all enclosures to mount to Model PTB PTB contains screw terminals for AC input power to connected Model PTB contains an AC line filter and power breaker rated at 5A From another on Model PTB AC power is connected directly Model PSC 12 via a keyed cable harness Each Model PTB building AC power connection circuits for two power supplies either one 1 for Model PSC 12 and 1 optionally for the Power Supply extender Model When more than one 1 Model PSX 12 Power extender is used a second Model PTB is and must be ordered separately PTB PTB has an optional connector that can be used system installation commissioning and service provide the technician with a place to plug in their computer if required Model AC ADPT is an accessory cable that allows connection on one to Model PTB via a keyed connector and on the end directly into to the laptop transformer Most external power transformers have removable AC cords which can be replaced by Model AC ADPT temporarily provide an AC power source for PCs used system installation service and maintenance when needed Power Supply Extender Auxiliary 24VDC Power Supply Total power output 12 Amp 24VDC Universal AC power input 120VAC 240VAC 50 60Hz Off line Switch Mode Power Converter Filtered Regulated 24VDC Provides 12A non power limited 24 VDC output use use Provides 4 Amp power limited 24VDC output Mounts on CAB MP one 1 module space Supervised Intelligent Module plain decimal addressing Communicates with PMI CPC via common 60 pin power data bus Ground fault detection circuit PTB Power Termination Board for AC field connections Models PSC 12 and PSX 12 share common back up batteries Up to three 3 PSX 12s connected to a PSC 12 charger UL 864 9th Edition Listed ULC Listed CSFM NYC Fire Department Approved Overview cid 326 Model PSX 12 Model PSX 12 Power Supply Extender is a auxiliary power supply that expands main Model PSC 12 power supply and battery for the FireFinder XLS system with an 24VDC power Model PSX 12 is rated at PSX 12 is an addressable intelligent module that its status to the system operator PMI to report fault conditions Model PMI able to query the status of the power supply to information regarding terminal loading ground fault conditions and more PSX 12 is a universal power supply accepting AC levels from 120VAC 240VAC and has off line switch mode power converter and power circuit to improve conductive RF at low frequency No special configuration required Industry Inc Technologies Division PSX 12 communicates via H Net protocol with system cards and modules via the system 60 pin power data bus Model PSX 12 a full 12 Amps of power 24