Siemens RNI Desigo Fire Safety Modular Remote Network Interface, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Fire Safety system Network Interface RNI Architect Engineer Specifications Connects equipment mounted in a lobby enclosure to Desigo Safety Modular system Built in transient protection Communicates via H Net and CAN protocols Supports Style 4 or Style 7 wiring CAN wiring Style 4 only Local sounder included Supports remote tamper switch UL864 CAN ULC S576 Listed FM NYC Fire Dept Approved Product Overview Remote Network Interface Model RNI provides a remote connection point for mounted within the lobby enclosure of the Desigo Fire Safety Modular fire alarm control panel FACP Model RNI is also used to provide remote input output and control features to each Desigo Fire Safety system FACP additional features may include control switches and indicators Models LCM 8 and FCM 6 remote emergency paging microphones or telephones LVM FMT controls used in graphic annunciators Models SIM 16 OCM or system status display with the ability to acknowledge alarm silence and reset the system Model SSD C REM Model RNI can be mounted in Model REMBOX2 or Model REMBOX4 remote lobby enclosure Specifications Remote Network Interface Model RNI can connect to the Control Area CAN bus through terminals on any Model PSC 12 Power Supply connection will allow the use of remote switches and light emitting diodes in the enclosure via the Switch Module Model SCM 8 the Fan Control Model FCM 6 and the LED Control Module Model LCM 8 a connection from Model RNI to the low level audio or telephone riser on Model PSC 12 power supply will allow the use of a remote microphone Model or a remote master telephone Model FMT in the enclosure Technologies Division RNI Network Interface Sheet 7324 Specifications continued RNI provides transient protection for system modules connected to it in the remote enclosure Model RNI also the connection of a local enclosure tamper switch A local sounder on Model RNI can be used to alert to conditions that need attention If required the sounder can be disabled by a jumper on the control board RNI can support all applications using 24 VDC power via a Model PSC 12 Power Supply or Model PSX 12 Supply Extender the system enclosure of each Desigo Fire Safety Modular system FACP from other UL Listed 24VDC power sources is also acceptable and Humidity Range are UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120 3 49 2 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 Ratings CURRENT DRAW Plane CURRENT DRAW Terminal CURRENT DRAW Plane CURRENT DRAW mA TYPE for Ordering Remote Network Interface for the Fire Safety Modular system 500 633772 500 633914 Remote Lobby Box Remote Lobby Box NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Technologies Division Fernwood Road Florham Park NJ 07932 973 593 2600 2017 New Issue 0

Related Files