Siemens RNI Remote Network Interface, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Installation Instructions RNI Network Interface Model RNI from Siemens Industry Inc allows for remote installation of the PMI PMI 2 PMI 3 XLS Desigo Fire Safety Modular Cerberus PRO Modular Global PMI XLS FCM2041 U2 Desigo Fire Safety FCM2041 U3 Cerberus PRO Modular on SSD C REM on HNET and the LVM LCM 8 on CAN modules used in a REMBOX4 the FMT and LVM are also HNET XNET can be wired either Style 4 or Style The RNI must be placed in between two NIC Cs used in a Style 7 Network with the Global PMI XLS FCM2041 U2 Desigo Fire Safety FCM2041 U3 Cerberus PRO Modular on or the SSD C REM HNET When using the XLS FCM2041 U2 Desigo Fire Modular FCM2041 U3 Cerberus PRO the RNI may be located in the middle or at end of the HNET Refer to the table below for the locations of modules at the end of a HNET XNET Placement at the End of a or XNET Network 4 Style 7 Style 4 Style 7 FCM2041 U2 Fire Safety FCM2041 Cerberus PRO HNET PMI PMI XLS Fire Safety FCM2041 Cerberus PRO XNET allowed Y Allowed Not allowed on this network 6 6 4 H 1 P V 1 Remote Network CAN network may only be wired Style 4 The RNI may be located at the end or in middle of a CAN network A 24VDC input is also required This can be obtained the PSC 12 power limited output TB3 Audio signals for the LVM and FMT are to TB1 of the PSC 12 The RNI mounts in the rear of either the REMBOX2 REMBOX4 enclosures It can also be installed in a CAB1 CAB2 or CAB3 using the plate RNI CAB BRKT The RNI provides terminal blocks for all field wiring Internal connections are made to plug in connectors specifically provided each of the installed modules The HNET XNET and the CAN networks can be simultaneously 315 033420 14 Inc Inc Inc Industry Inc Inc TTTTTececececechnologies Di Di Di Division Di enables or disables an audible device similar to the CSB This audible sounds a switch is pressed on either the LVM SCM 8 or the FCM 6 If this is not the audible can be silenced by changing the jumper installed on P7 to 2 and 3 P7 is configured in the factory positions 1 and 2 to have the active is used to terminate the HNET XNET If the RNI is installed at the end of an HNET S1 must be set to the ON position If the RNI is in the middle of the HNET set S1 to the OFF position must be set to the HNET H position to select HNET or the XNET X position to XNET Only one network either HNET or XNET can be used all system power before installation first battery then AC To power up the AC first then the battery PSC 12 TB3 ANY UL ULC LIMITED SUPPLY FOR FIRE USE 2 The 24VDC Input TO ON 3 HNET XNET At The End Of The Network Style 4 and Style 7 PMI PMI 2 PMI 3 XLS FCM2041 U2 Desigo Fire Safety Modular Cerberus PRO Modular Only For Style 7 315 033420 14 14 18 AWG 2A max input current Supervised Refer to PSC 12 PSX 12 Instructions 315 033060 for to TB3 and fault detection No EOLR required 18 AWG min 14 AWG max 2000 feet max per pair Use twisted pair Style 4 7 twisted shielded pair 4 only Power limited to NFPA 70 NEC 760 Refer to NIC C Installation P N 315 for connection of and B pairs and ground detection impedance Omit B pair for Style 4 All wiring supervised Industry Inc Technologies Division RNI NEXT RNI No EOLR required 18 AWG min 14 AWG max 2000 feet max per pair NIC Cs Use twisted pair Style 4 7 twisted shielded pair 4 only Power limited to NFPA 70 NEC 760 Refer to NIC C Installation P N 315 for connection of and B pairs and ground detection impedance Omit B pair for Style 4 All wiring supervised TO OFF 4 HNET XNET In The Middle Of The Network Style 4 and Style 7 NOT 18 AWG min 14 AWG max 15 ohms max for CAN Use twisted pair or twisted pair NEC 760 Power limited to NFPA 70 Refer to NIC C Installation P N 315 for connection of CAN Only 1 SCM 8 shown SCM LCM 8 FCM 6 OCM 16 all allowed All field wiring supervised Refer to PSC 12 Installation P N 315 for ground fault impedance Industry Inc Technologies Division SUPPLIED WITH THE RNI NOT TO ID MP INNER DOOR REMBOX2 4 0 0 TERMINATOR 110 134215 WITH NIC C 5 CAN At The End Of The Network 315 033420 14 NEXT 1 CCL P N 599 634214 IS SUPPLIED WITH THE RNI 6 CAN In The Middle Of The Network 0 0 TO ID MP INNER DOOR REMBOX2 4 18 AWG min 14 AWG max 15 ohms max for CAN Use twisted pair or twisted pair NEC 760 Power limited to NFPA 70 Refer to NIC C Installation P N 315 for connection of CAN Only 1 SCM 8 shown LCM 8 FCM 6 SIM 16 all allowed All field wiring supervised Refer to PSC 12 Installation P N 315 for ground fault impedance 18 AWG min 14 AWG max 15 ohms max per pair Use twisted shielded pair for microphone and speaker Use twisted pair or twisted pair for phone Power limited to NFPA 70 NEC 760 Microphone and phone are supervised Monitor speaker is NOT Refer to LVM Installation P N 315 034090 Refer to FMT Installation P N 315 034100 No End Of Line devices Refer to PSC 12 Installation P N 315 for ground fault impedance 7 The LVM and FMT Industry Inc Technologies Division 315 033420 14 PMI PMI 2 PMI 3 XLS FCM2041 U2 Desigo Fire Safety Modular FCM2041 U3 Cerberus PRO RNI mounts on studs in the rear of either the REMBOX2 or the REMBOX4 Four nuts are provided with the RNI Refer to the REMBOX2 REMBOX4 Installation P N 315 033772 For Global PMI PMI 2 PMI 3 XLS FCM2041 U2 Fire Safety Modular FCM2041 U3 Cerberus PRO Modular applications the can also be installed in a CAB1 CAB2 CAB3 using mounting plate RNI CAB P N 500 650062 Refer to RNI CAB BRKT Installation Instructions P N 315 Install the RNI with the terminal blocks facing up to allow for easier connec of the field wiring 40 inch long 60 wire cable P N 555 133743 shipped with the PMI PMI 2 PMI 3 FCM2041 U2 Desigo Fire Safety Modular FCM2041 U3 Cerberus PRO connects the RNI to the PMI PMI 2 PMI 3 XLS FCM204

Related Files