Siemens SBGA-34 Audible Base, Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name siemens-sbga-34-audible-base-installation-instructions-4038725916.pdf
Type PDF
Size 725.59 KB
Downloads

Text Preview

INSTALLATION INSTRUCTIONS SBGA 34 Base Model SBGA 34 Audible Base from Siemens Industry Inc consists of a standard Series 11 base with an audible device compatible with all H series 8700 series Desigo and Cerberus series detectors All field wiring terminates at two four position terminal blocks located on the back the unit The SBGA 34 is used with the polarity insensitive HFP 11 HFPT 11 HFPO 11 SFP 11 and SFPO 11 8710 8712 8713 FDO421 FDT421 FDOT421 FDOOT441 FDOOTC441 OH921 HI921 OOH941 OOHC941 detectors The SBGA 34 operates as described below to Figures 1 2 3 4 5 6 and 7 for proper wiring connections SFPT 11 and SFPO 11 detectors are approved for use in CANADA only 3 WIRE INPUT VAC 50 60 Hz TO GROUND OF THE PANELS CONNECTED TO REFER TABLE X FOR GROUND 4 CONNECTION SLC LOOP 2 1 2 7 WIRE THE OPTIONAL MM 35 IS NOT USED SUPERVISORY CONNECTION MODEL MUST BE INSTALLED AT P2 IN THE BC 35 OR BE 35 MODEL P1 CONNECTION USE OR EQUIVALENT AND AS NECESSARY VDC 1 WIRE FROM PIN 3 OF LAST MODULE WIRE Polarity shown in active state at terminals 1 and 2 of SBGA 34 Proper must be maintained or audible base will not operate properly audible base must be tested to verify operation Use a Model MPI 2 mounting plate to mount a HTRI R in a System 3 HTRI R relay should be programmed to activate on alarm condition For more detailed wiring information refer the HTRI R Installation Instructions P N 315 033300 Tone selection refer to page 7 for more i nformation HTRI R and SBGA 34 are polarity insensitive Line 1 and Line 2 can either line of the loop 4 1 DLC LOOP OF 2 OR FS DLC LOOP OF FS 250 SYSTEM 3 1 3 1 Z A Y B 2 NEXT DB3S OR DB 11 1 1 Diagram for SBGA 34 Powered by Auxiliary Power Supply with Battery Backup Industry Inc Technologies Division Park NJ A6V10383428 a en 2 Diagram for SBGA 34 Audible Powered by ZIC 4A FireFinder XLS System 3 2 DLC LOOP OF 1 2 3 NEXT 1 2 2 2 3 4 Polarity shown in active state at terminals 1 and 2 of SBGA 34 and 1 4 of ZIC 4A polarity must be maintained or audible base will not operate properly Each base must be tested to verify operation Tone selection refer to page 7 for more information SBGA 34 terminals 5 8 are polarity insensitive Line 1 and Line 2 can be either line the loop SBGA 34 shown Style Z Class A It may also be wired as Style Y Class B ZIC 4A Notification Applicance Circuits provide 4 outputs that can be configured for A or Class B Refer to the ZIC 4A Installation Instructions P N 315 033050 EOL resistor 24k ohms watt 5 P N 140 820405 For synchronized operation using the ZIC output tone selection in the SBGA 34 be set to Steady 3 2 DLC LOOP OF 1 2 3 NEXT 1 2 2 2 3 4 1 5 6 7 8 Polarity shown in active state at terminals 1 and 2 of SBGA 34 and 1 4 of ZIC 8B polarity must be maintained or audible base will not operate properly Each base must be tested to verify operation Tone selection refer to page 7 for more information SBGA 34 terminals 5 8 are polarity insensitive Line 1 and Line 2 can be either line the loop SBGA 34 shown as Style Y Class B ZIC 8B Notification Applicance Circuits provide 8 outputs that can be configured for B Refer to the ZIC 8B Installation Instructions P N 315 048670 EOL resistor 24k ohms watt 5 P N 140 820405 For synchronized operation using the ZIC output tone selection in the SBGA 34 be set to Steady 3 Diagram for SBGA 34 Audible Powered by ZIC 8B FireFinder XLS System 3 2 FS DLC OR FDLC OF FS 250 FS 250C SYSTEM 1 3 2 NEXT 1 2 2 NC NO Polarity shown in active state at terminals 1 and 2 of SBGA 34 and 1 1 2 and 2 FS 250 FS 250C NAC cirucits Proper polarity must be maintained or audible will not operate properly Each audible base must be tested to verify operation Tone selection refer to page 7 for more information SBGA 34 terminals 5 8 are polarity insensitive Line 1 and Line 2 can be either line the loop SBGA 34 shown Style Z Class A It may also be wired as Style Y Class B FS 250 FS 250C Notification Applicance Circuits TB12 and TB13 provide 4 that can be configured for Class B or two outputs that can be configured for A Refer to the FS 250 Operation Installation and Maintenance Manual P N or the FS 250C Operation Installation and Maintenance Manual P N as applicable to set jumpers JP1 4 for Class A or Class B operation EOL resistor 24k ohms watt 5 P N 140 820405 4 Diagram for SBGA 34 Audible Powered by NAC Circuits FS 250 FS 250C Systems MPC6000 MPC7000 3 2 1 2 3 NEXT 1 2 2 PAD 3 CIRCUIT PAD 3 CIRCUIT 5 2.2K 1 2W 140 820380 NAC circuits polarity shown in active state Proper polarity must maintained or audible base will not operate properly Each base must be tested to verify operation Tone selection refer to page 7 for more information SBGA 34 is polarity insensitive Line 1 and Line 2 can be either SBGA 34 shown Style Z Class A It may also be wired as Max Current 3.0 AMPS Refer to PAD 3 Installation Instructions of the loop Y Class B 315 099082 5 Diagram for SBGA 34 Audible Powered by PAD 3 3 2 P2 FC 901 PANEL 1 3 2 NEXT 1 2 2 Polarity shown in active state at terminals 1 and 2 of SBGA 34 and 1 1 2 and 2 FC 901 NAC circuits Proper polarity must be maintained or audible base will not properly Each audible base must be tested to verify operation Tone selection refer to page 7 for more information SBGA 34 terminals 5 8 are polarity insensitive Line 1 and Line 2 can be either line the loop SBGA 34 shown Style Z Class A It may also be wired as Style Y Class B FC901 Notification Appliance outputs that can be configured for Class B or Class A to the FC 901 Operation Installation and Maintenance Manual P N 315 as applicable to set jumpers JP1 4 for Class A or Class B operation 6 Diagram for SBGA 34 Audible connected to FC901 Panel 3 2 P2 FC2025 2050 1 2 3 NEXT 1 2 2 Polarity shown in active state a

Related Files