Siemens SP40S Emergency Communications Voice Evacuation System, data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Communications Voice Evacuation System AND ENGINEER SPECIFICATIONS Eight 8 digitally recorded voice messages with live microphone override Uses only one 1 tone for messages Supervised speaker and strobe notification appliance circuits NACs Broadcast capability from a supplied background music BGM source Unique supervision method allows for full system supervision a BGM mute feature during BGM broadcasting Easily interfaces with many existing phone system page ports C O port and line level signals Removable quick connect disconnect terminals for ease of wiring 12 to 22 American Wire Gauge AWG Power limited circuitry via A or B wiring A wiring only with the use of an audio splitter Night ringer or security alert connection NFPA 72 OSHA 1910.165 and ADA Compliant UL 864 9th Edition Listed ULC Listed CSFM NYC Fire Department Approved Overview Model SP40S is a multi functional paging messaging BGM delivery and voice evacuation system that can interface many Siemens fire alarm systems Further SP40S provides full control of building audible visual NACs single channel system is capable of delivering 40 of supervised high quality audio power and 2 of supervised 24 VDC synchronized strobe power SP40S is supplied with a 24VDC back up battery SP40S comes standard with an on board digital system containing any of the following Eight 8 standard messages One 1 hand held microphone One 1 power supply battery charger Several additional features SP40S is also expandable to 5280 Watts the following Model SPB 80 4 80 Watts 4 Amps of strobe power Model SPB 160 160 watts or Model SPB 320 watts supervised audio power boosters Industry Inc Technologies Division shall be a multi purpose NFPA compliant and general purpose audio system for communications voice evacuation The voice output for the system shall be incorporating supervision during the of general paging BGM system shall be capable of delivering 40 Watts of audio power and 2 Amps of supervised 24 synchronized strobe power audio power shall be 40 Watts minimum to 5280 Watts depending on system as well as additional modules and power Supervised 24 VDC synchronized strobe power be at 2 Amps expandable to the requirements of installation system shall be capable of operating from a 120VAC source Model shall be capable of from a 240VAC power source models shall have a 24VDC back up battery and are in either 115 VAC or 220 VAC System Overview 3750 power supply charger section shall be able to 24VDC batteries with a maximum capacity of 33 hours Up to two 2 12VDC 12AH batteries may housed in the enclosure Batteries larger than 12AH be housed in a separate enclosure Batteries shall supplied separately system shall have power limited circuitry with wiring Wiring terminal blocks will be removable and AWG wiring Data Power Current Draw Draw Frequency Response Connection Outputs Ratio Range Harmonic Distortion Dimensions W x H x D 120 VAC 60 Hz per amplifier board Amps per amplifier board Voice 400 6.5 kHz BGM 275 15 kHz 22 Wire Gauge AWG or 70.7V power limited 65 db 65 db x 21 x 6 cm x 53.3 cm x 15.2 cm Lbs 16329 g or Red enclosure Overview continued on board system features shall include Digital voice messaging One 1 hand held push to talk with override priority One 1 power supply battery charger system shall be capable of interfacing with systems for general paging and will have night ringer C contacts shall be provided for fire Alarm and Trouble conditions system shall have eight 8 message contacts with activation Input voltage for BGM shall capable of handling less then 2.5V peak to peak or then 0.3 volts The system shall have 13 priority inputs including One 1 on board microphone One 1 auxiliary line level input Eight 8 digital messages One 1 night ringer input One 1 telephone paging input and One 1 BGM input system shall have preset audio levels for emergency pre recorded and live intercom The system revert back to a pre set level regardless of the set for BGM or for general paging inputs can be tied to an AM FM tuner cassette disc CD MP3 or any other remote source system shall be supplied with eight 8 pre recorded and shall be capable of in field recording of messages SP40S shall have a dual tone tone generator with Tone and Slow Whoop When the system is on power telephone page night ring and BGM shall disengaged shall have power limited circuitry with an battery charger and power supply and Activation Inputs of Input PTT microphone microphone or remote microphone expander activation input input input 600 ohm voltage must be 2.5V peak to peak or 0.3 VRMS Ordered Microphone Message Input 1 Message Input 2 Message Input 3 Message Input 4 Message Input 5 Message Input 6 Message Input 7 Message Input 8 Ringer Input Paging Input Music Input Industry Inc Technologies Division Diagram SP40S Front Keypad View Industry Inc Technologies Division not use not use Clear Types Script 3 rounds of Code 3 horn followed by I have your attention please A fire emergency has been reported in the building While is being verified please leave the building by the nearest exit Do not use the elevators 3 rounds of Code 3 horn followed by I have your attention please A fire emergency has been reported in the building While is being verified please leave the building by the nearest exit Do not use the elevators 3 rounds of Code 3 horn followed by I have your attention please A fire emergency has been reported in the building this is being verified please leave the building by the nearest exit 3 rounds of Code 3 horn followed by I have your attention please An emergency has been reported in the building While this is being verified please leave the building by the nearest exit 3 rounds of Code 3 horn followed by I have your attention please An emergency has been reported in the building this is being verified please leave the building and report to the designated assembly for your group 5 seconds of 1kHz Tone followed by I have your attention please National Weather Service has issued a severe weather warning for our area 5 seconds of 1kHz Tone followed by I have your attention please The building emergency has ended clear has been given Please resume normal activities 5 seconds of 1kHz Tone followed by I have your attention please This is a test of the evacuation system this is only a test Each message can be selected to have a code 3 pre alert tone 1kHz continuou

Related Files