Siemens TXR-320 Pre-Action, Deluge and Agent-Releasing Conventional FACP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-txr-320-pre-action-deluge-and-agent-releasing-conventional-facp-1240873569.pdf |
---|---|
Type | |
Size | 1.07 MB |
Downloads |
Text Preview
s Sheet Safety Products Releasing Control Panel Deluge Agent Releasing Fire System TXR 320 AND ENGINEER SPECIFICATIONS Remote configurable Up to two 2 hazard areas Operable with the following Deluge sprinkler system Pre action sprinkler system Agent release system Abort release timer functionalities Standard UL type delay IRL type delay NYC type delay Local jurisdiction AHJ delay Power supply notification appliance circuit NAC power 5 Amps max Avoidance to potential false dumps via special releasing supply and release activation considerations Class A circuit configuration Via optional module Six 6 Class B input circuits Four 4 Class B output circuits Optional configuration tool contains a backlit 20 character display LCD screen of up to two 2 lines Basic fire system programming accomplished 13 modes of pre configured operation Compatibility listed with Models HI121 OH121 and OP121 detectors Each conventional detector utilizes the Model DB 11 detector base Overview TXR 320 from Siemens Fire Safety is a dual field configurable fire alarm control panel used on deluge sprinkler pre action sprinkler agent release Sinorix Engineered Fire systems configuration is accomplished from the front via the selection of 13 pre configured modes of Advanced features can be configured via system optional configuration tool Model TCFG no laptop personal computer PC is required TXR 320 is equipped with six 6 Class B input circuits and four 4 Class B Y output rated at 1.7 Amps maximum total capacity of per system Optional A converter modules available for both input and output circuits Maintenance and technician level for added security Optional city tie module UL 864 9th Edition Listed 7165 0067 0270 Approved internal and external relays are supported Model TXR 320 configurable for single hazard and applications Supervisory and Trouble conditions are indicated a two line 20 character backlit LCD display and system status light emitting diodes LEDs membrane control buttons serve as the input Acknowledge Alarm Silence and System Reset functionality Basic user and maintenance functions such as Viewing History or System Disable are also accomplished through the buttons added security maintenance level are password protected Deluge Agent Releasing FACP TXR 320 3500 Industry Inc Technologies Division Overview continued Model TXR 320 FACP ships complete as a enclosure with door durable key lock and space to mount up to 12AH batteries TXR 320 FACP with Model HI121 OH121 OP121 conventional which each utilize the standard Model DB 11 base Model TXR 320 FACP is UL 864 9th Edition by Underwriters Laboratories and is CSFM Approved compatibility are six 6 B B input circuits to Model TXR 320 Pre Action Deluge Agent FACP Input circuits 1 4 can be configured Alarm Non Latching Latching Supervisory or Agent Release Flow based on the selected operation mode input circuits 5 6 can be programmed as Manual Release Input Abort Input or Abort Release Combination Input depending on designated operating mode signals can be configured for fixed or tone changes as input operation changes 3 and 4 the panel output circuits can be as any of the following Silenceable signal strobe Non Silenceable strobe or circuit contacts are configurable for the following commands common Alarm which cannot be auxiliary Alarm disconnection capable Supervisory and common Trouble Common Supervisory command can be converted for a Alarm event provided no Supervisory input is used zoning is an optional feature to each Model TXR FACP For cross zone monitoring Inputs 1 and 2 active zones on Output 3 while Inputs 3 and 4 are zones on Output 4 Modules TICAC Industry Inc Technologies Division Class A Input Circuit Converter Module TICAC converts six 6 Class B Style B inputs each Model TXR 320 to Class A D circuits leads are used on Model TICAC for connection to TXR 320 main board Model TICAC mounts to right of the main board initiating circuits which use B Style B wiring and includes a built in end EOL resistor TOCAC Class A Output CircuitConverterModule TOCAC converts four 4 Class B Style Y circuits on Model TXR 320 FACPs to two 2 A Style Z circuits Every Model TOCAC is with wire leads to establish connection with TXR 320 main board Model TOCAC mounts the right of the main board indicating circuits TRM 306 Relay Circuit Adder Module TRM 306 provides six 6 Form C configurable circuits rated 28 VDC 1A resistive Model TRM 306 Form C circuit can be configured a normally open N O or normally closed N C Additionally each Form C relay is equipped a LED which will illuminate when the relay is The relays can be configured as relay per common on Alarm common on 1 to 1 or programmable for logical or adjacent configuration adjacent zone configuration will turn on the closest when the configured zone is active A chaining allows multiple relays to duly function TCFG 300 Configuration Tool configuration tool Model TCFG 300 plugs into the board of every Model TXR 320 FACP offering a 2 by 20 character LCD Model TCFG 300 Model TXR 320 LED version FACPs and push on the main board Modules cont Configuration Tool configuration mode the disconnect buttons for and indicating circuits act as function keys the zone labels reveals the programming buttons TCFG 300 is used only for configuration only not for normal operation TPR 300 City Tie Reverse Polarity Module TPR 300 provides outputs for city tie box and applications As a city tie module TPR 300 serves as an interface between the and a master box TPR 300 also provides off premises signal for systems that must comply with NFPA for auxiliary protective systems a reverse polarity module Model TPR 300 provides interface between Model TXR 320 and a reverse receiver with bi color LEDs Remote LED Annunciator Model TRAM 208 remote LED annunciator offers 8 points of LED annunciation Model TRAM 208 are configured for either Alarm RED or AMBER TRAM 208 also has indicators for alternating AC common Trouble as well as signal and controls for system reset lamp test fire buzzer silence and signal silence Model TRAM also allows for the control switches to be disabled a per function basis TSRM 312 Smart Relay Module TSRM 312 provides 12 Form C configurable circuits rated 28 VDC 1A resistive Each which can be configured as a N O or N C is equipped with a LED that will illuminate the relay is energized Industry Inc Technologies Division Smart Relay Module continued relays can be configured as relay per zone common on Alarm commo