Siemens XAS-1-US, XAS-2-US Addressable Air-Aspiration Duct Smoke Detectors, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-xas-1-us-xas-2-us-addressable-air-aspiration-duct-smoke-detectors-data-sheet-6014982375.pdf |
---|---|
Type | |
Size | 1.46 MB |
Downloads |
Text Preview
Sheet Safety Products Detection Devices Air Aspiration Special Application Smoke Detectors with compatible Siemens Intelligent Addressable Detectors XAS 1 US XAS 2 US AND ENGINEER SPECIFICATIONS High performance aspirator Microprocessor controlled operation Integral display and programmer Single or dual channel fire detection Compatible with various Siemens addressable detectors Multiple configuration options Sample pipe length up to 164 ft 50 m Adjustable aspirator speed airflow monitoring meet unique and Field serviceable air filter Overview air sampling special application smoke provides a specialized flexible detection and industrial sites Single inlet and are the two 2 types of duct housings for this innovative duct sensor application series is Underwriters Laboratories UL ULC Listed for use with the Siemens spot as well as with Siemens Model DB 11E base Each air aspiration device is conducive for inaccessible areas as well as of a building where each detection device be mounted outside the protected area examples of exterior mountings suited for specialized detection devices include correctional facilities transformer vaults cable tunnels elevator hoist areas heating ventilation and HVAC ducts Industry Inc Technologies Division Sensor Housing XAS 1 US Sensor Housing XAS 2 US UL268 268A Listed ULC S529 Listed 7259 1728 0124 Approved with Siemens Fire Safety fire alarm control FACPs that are compatible with Model addressable detectors each of these duct actively draws air from the protected area sampling holes in a pipe network Sampled air filtered and analyzed by Siemens addressable detectors incorporated in single inlet or dual inlet duct housing high performance aspirator which is used in with programmable flow monitoring allows these devices to function quickly effectively Air flow level is displayed on a 10 bar graph that can be adjusted for high low flow thresholds Flow failure is reported a device fault event via relays sent to the FACP duct device is available with one 1 pipe Model XAS 1 US or two 2 inlet Model XAS 2 US and can be used one 1 or two 2 detectors per FACP Air Aspiration Smoke Detection System 6158 continued device may be configured for a number of strategies including single or dual addressable area detection redundant detection multi criteria detection coincident or double knock two 2 detectors with one 1 alarm detection intelligent addressable detectors offer in simplicity of configuration and cost Options configuration options are available for XAS 1 US and XAS 2 US XAS 1 US devices one 1 Siemens intelligent detector XAS 2 US devices two 2 compatible addressable detectors XAS 1 US which is used with one 1 Model detector is capable of providing one 1 area However Model XAS 2 which two 2 Model HFP 11 detectors is able to more than two 2 types of detection table below describes the recommended options to fit the selected detection Siemens when detectors are either XAS series duct sensor housing Addressable Areas Criteria OR OR AND OR AND OR Double Knock AND AND denotes detection strategy is subject to local codes standards OR AND represents the suggested Boolean logic for two detectors to achieve detection strategy Data Draw Control Pressure Monitoring Reporting Pipe Sizes Rating Range Humidity Length Outputs Types Dual Inlet W x H x D max programmable speeds psi 250Pa Design Admissible terminals 18 Wire solid 20 filter filter optional Low adjustable speeds Inner Diameter Outer Diameter 2.2 cm 2.7 cm 65 140 F 60 C to 95 feet 50m per inlet Pipe length may vary subject to by local codes refer to the regional XAS guide for further detail 1 fault Model XAS 1 US 2 faults Model XAS 2 US One 1 or up to two 2 compatible intelligent detectors 12.6 6.5 cm 32.1 cm 16.6 cm VDC nominal Spot point detectors are powered from the Signaling Line Circuit SLC or Device Circuit IDC s Intelligent Devices for Model Series XAS Part Number UL File UL Volume ULC File ULC Volume S24106 S24106 S54320 F7 A1 S2346 S54320 F7 A2 S2346 S54320 F8 A1 S2346 S54320 F8 A2 S2346 Industry Inc Technologies Division Photoelectric Smoke Detector PRO Smoke Detector Multi Criteria Fire Detector ASAtechnology PRO Multi Criteria Fire Detector ASAtechnology Multi Criteria Fire CO Detector ASAtechnology PRO Multi Criteria Fire CO with ASAtechnology FirePrint Detector insensitive via SureWire technology Diagrams for Ordering continued Tubing single core tubing ft 15.24m single core tubing ft 7.62m for Ordering S54331 Z2 A1 S54331 Z3 A1 Single zone air sampling unit UL Listed for use with Siemens addressable spot as well as with a Siemens mounting base Requires external 24VDC power Dual zone air sampling unit Listed for use with Siemens HFP 11 spot detector and mounting base Requires external 24VDC power Refer to Siemens Installation Manual 315 094193 for further on the Siemens Model of detector bases Industry Inc Technologies Division for Ordering continued Kit S54331 Z14 A1 S54331 Z15 A1 duct sampling kit use with Model XAS 1 US includes the following One 1 tube mounting plate Compression fittings Adaptors Elbows Reducers duct sampling kit use with Model XAS 2 US includes the following Three 3 tube mounting plates Compression fittings Adaptors Elbows Reducers Kit S54331 Z16 A1 S54331 Z17 A1 water tra