Silent Knight 5104 Digital Alarm Communicator Transmitter 6 Zone
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-5104-digital-alarm-communicator-transmitter-6-zone-5832690471.pdf |
---|---|
Type | |
Size | 1.18 MB |
Downloads |
Text Preview
FIRE ALARM ACCESSORY Fire Control speed reliability and value digital communications from company you can trust pioneers in digital fire technology Silent Knight delivers superior systems at an outstanding value Our 5104B Control Communicator has become the industry standard by proving itself in years of field tested operation four zone fire control communicator provides fast reliable digital communication of fire and trouble It transmits via ordinary phone lines eliminating the need for expensive leased line arrangements it as a stand alone or incorporate it into your existing system Why spec any other digital communicator Go the industry standard the 5104B Fire Control Communicator from Silent Knight more information please call 1 800 328 0103 5104B Control Communicator Silent Knight Model 5104B is a fire control communicator digital fire reporting over telephone lines the need for costly lines It UL 864 and NFPA approved for monitoring local controls a stand alone unit it can be to monitor Sprinkler systems for waterflow and gate valve conditions Automatic fire detection systems structures that are not to have a fire alarm but want property e g to call the fire after hours Monitors dry contact alarms and supervisory outputs transmits a separate code each Model 5104B is fully Its microprocessor runs programs to AC standby battery zone and telephone line If a fault condition is it sounds a local trouble and reports the condition to central station If one of the lines faults for more than seconds it will automatically to the other to report the communicator will signal restoration and trouble on any of the six inputs an application requires a different configuration the individual styles may be changed by a Model 7181 Fire Zone Module The 7181 also use of two wire type smoke instead of the normal contact type for fire detection UL 864 Listed as an NFPA 72 Station or Remote Station premise unit FM approved Can be used as a stand alone or as a DACT Six fully supervised inputs one Class Style D input and five Class B A inputs Downloadable for remote Fuseless overload protection with reset circuitry and fault eliminates the cause of field calls 5104B Dual phone line interface Automatic tests every 24 hours with report to central station Reports in SIA and most major formats 60 hours of standby power Operates on loop start phone lines of the building PBX system A single programmable output is for alarm or dialer failed cannot be used for purposes 350349 Rev D 2016 Honeywell International Inc ALARM ACCESSORY VAC 60 Hz 40 watts Fire Control Applications UL Listed mA mA Alone Applications VAC 60 Hz 40 watts volt 7 amp hour rechargeable battery Remote Annunciator three maximum per system mA standby mA alarm Lights LEDs On Green Silenced Yellow Trouble is Cleared Flashing Supervisory Failure Yellow Line Fault 2 Red Cabinet at L1 and L2 Inputs Requirements Registration AC698R 17462 AL E EQUIVALENCE 0.0B of Jack RJ31X 2 required W x 14.5 H x 3.0 D W x 36.8 cm H x 7.6cm D lbs 6.75 kg Accessories Remote Annunciator Programmer Download Package Fire Zone Converter Module Telephone Connecting Cord for RJ31X Jack 2 12 volt 7AH rechargeable battery SK 4 2 Listed UL864 NFPA 72 Central and Remote Fire Alarm System Service Approved Approved BFSK SK 3 1 Sescoa 3 1 Contact Model 5560 SKSS Software for remote programming status checking of the 5104 allows the installing to view the default modify it and if troubleshoot the The downloading software contains programs for other Knight downloadable It is available to at www silentknight com 5230 Remote Annunciator 5104 can be programmed the use of the optional 5230 Remote Alphanumeric Programming options telephone numbers format account number response times electronic test time output activation and installer codes System is stored in a non EEPROM chip which is hundreds of times 5104 accommodates up to remote annunciators via a connection A quick plug allows temporary of the annunciator for 5230 ALARM ACCESSORY Fire Control 60 Hz FIRE KNIGHT 5104B Channel Contact Typical Contact Typical 5104B BLOCK DIAGRAM DACT Application Knight 5230 Annunciator max per system Line 1 Line 2 RJ31X 60 Hz A Input 5 waterflow as per NFPA 72 B Inputs valve tamper or PIV must connect open KNIGHT 5104B Channel Knight 5230 Annunciator max per system 6712 7 AH Line 1 Line 2 RJ31X 5104B BLOCK DIAGRAM Waterflow Application ALARM ACCESSORY Fire Control contractor shall provide an digital communicator to the fire alarm and supervisory trouble signals to a central station digital communicator shall be UL FM listed for fire reporting to a station and shall conform to the of NFPA 72 digital communicator shall provide and necessary components for supervised detection circuits One be Class A Style D and three be Class B Style A The circuits shall accommodate flow switches gate valve switches thermal detectors contact type smoke detectors as desired and permitted by 72 control communicator shall have capability to supervise two lines seize the phone line send the alarm signal on one or lines without the addition of any equipment It shall test each line number at alternating intervals in accordance with 72 It shall sound a local trouble if the telephone service is for longer than 60 seconds it shall transmit a signal indicating loss of phone line service to the station over the remaining line A signal shall also be to indicate the restoral of service The shall be able to the loss of either phone line regard to which phone line first If both lines fail a local shall sound control communicator shall have ability to send a test signal to the station every 24 hours The test shall be able to be transmitted at specific time of day or night by a program within the panel digital communicator shall provide secondary power supply utilizing batteries The secondary shall be capable of supplying under maximum normal load 24 hours for central station or applications or 60 hours for supervising station system in accordance with NFPA communicator shall be able to all signals in the Standard SIA Security Industry Association alarm signals transmitted to the station shall indicate which of four zones is in alarm and which are in trouble Restoral from or trouble shall be capable of to Silent Knight and industry standard receivers document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 12 Clintonville Road Northford CT 06472 Phone 800 328 0103 Fax 203 484 7118 For Technical Support Please call ww silentknight co