COMMERCIAL FIRE ALARM CONTROL PANEL 5207 Control Panel with Digital and Accu Zone All In One Answer For Fire Protection Model 5207 is an all in one fuseless local evacuation control panel and digital designed for applications requiring manual fire alarm automatic fire alarm and flow for sprinkler supervision The basic unit offers fire alarm for one to eight zones to 16 with the optional 5210 expansion module It is compatible with both two four wire smoke detectors Compact easy to install and service it delivers the features expect to find in fire systems costing much more Eight zones 6 Class B Style A and Class A Style D 8 expander and Class B Style A Zones interchangeable using the Model Zone Converter UL FM MEA BSA CSFM listed Approved Event Memory Fuseless design reduces service 24 VDC power supply Compatible with 2 and 4 wire detectors as well as water and sounding devices ANSI cadence pattern output Four programmable Style Y signal circuits including pulse and temporal Programmable smoke verification delay and cross zoning minimize false alarms Four general purpose relays Form 24 V at 2.5 A resistive Built in approved digital with UL required reporting Flexible programming capabilities up downloading and use of annunciator Accu Zone diagnostics facilitate and remote troubleshooting Walk Test form C Relays Volts 2.5 amps Lights Green Red to 120 to 49 running on DC Power Alarm Alarm Yellow ON Trouble Condition Troubles Yellow ON If trouble or alarm been silenced Yellow ON if an Alarm is Mode Yellow panel is in test or mode reporting Voltage VDC AC DC Load VRMS 60 Hz 24 VDC mA mA max W x 26.4 H x 4 D cm W x 67 cm H 10.2 cm D FIRE ALARM CONTROL PANEL 5207 Control Panel with Digital and Accu Zone AAcccceessssoorriieess 5230 Remote Annunciator 4 wire 16 zone remote English language is easy operate Its fourteen function keys perform the same operations as main system annunciator including resetting and the displaying alarms troubles and alarm memory Model 5230 can be used to all programmable options and the use of access codes prevent tampering Expansion 5210 adds eight additional Class B A zones to the 5207 enabling of both 2 and 4 wire smoke SSppeecciiffiiccaattiioonnss 4180 Status Display Module 4180 provides 16 outputs to give and trouble conditions by zone units can be connected to all 16 zones on a 5207 The 16 outputs can be used to LEDs or a graphic annunciator 7181 Fire Zone Converter Class B zones to Class A and versa 5220 Direct Connect Module for city box and polarity reversing wire applications 5530 Downloading Modem format modem for remote the 5207 Downloading Software remote programming the 5207 with IBM or compatible personal Requires a 5530 modem modem and software can be as a package order P N Printer Interface connection of a standard printer to provide a printed of the 5207 system activity not supplied contractor shall provide a complete electrically supervised fire alarm and communications system The system shall contain a fire alarm and panel to supervise and operate heat and product of combustion detection devices alarm signal devices visual annunciator and an digital communicator to transmit fire alarm and supervisory signals to a central station The control communicator shall be UL listed or FM approved for NFPA 72 for Central Station Local Protection Remote Signaling and Auxiliary Signaling standards It shall provide power and control for eight supervised zones four supervised alarm signal circuits and a dual phone line digital communicator The control communicator shall be expandable to sixteen detection zones and shall be able to communicate to a central station in SIA SK FSK1 SK 4 2 or Radionics BFSK formats The shall be model 5207 shall be two Class A and six Class B detection zones They shall accommodate heat detectors products of combustion detectors manual pull stations flow switches and gate valve supervisory switches intermixed as permitted by NFPA 72 Products of combustion may either be 2 or 4 wire and shall be listed by UL for use on the system The detection zones shall be programmed to 1 be cross zoned so that two individual zones must sense products of 2 automatically reset a detector to verify that products of combustion exist 3 see a single detector in alarm before the alarm is sounded and a is transmitted to the central station shall be four 1 amp supervised Style Y alarm signal circuits They shall cause the notification appliances to ring steady pulsing temporal throughout the until reset or silenced control shall be equipped with four auxiliary relays that shall be programmed to operate on 1 pre alarm 2 tamper alarm 3 special alarm 4 fire alarm trouble 6 no silence 7 alarm by specific zone 1 16 The relays shall remain energized until the panel is silenced reset or the trouble condition is unless is selected control communicator shall have an integral annunciator to indicate sequentially zones in trouble and system functions LEDs shall augment the display to clear to an operator the system status Am integral touchpad shall be provided to operate and interrogate the system Vital operations such as alarm or reset shall be simple and obvious to an operator Authorization pass codes may or may not be used control communicator shall have the capability to supervise two telephone lines seize the phone line and send the alarm signal on one or both lines without addition of any more equipment It shall sound a local trouble signal if the telephone service is interrupted for longer that 45 seconds and it shall transmit a indicating the loss of phone line service to the central station over the remaining phone line A signal shall also be transmitted indicating the restoral of service The control communicator shall be able to report the loss of either phone line without regard to which line failed initially If both lines fail a local shall sound control communicator shall have the ability to send a test signal to the central station every 24 hours the test signal shall be able to be transmitted at a time of day or night by setting a program feature within the panel alarm signals transmitted to the central station shall indicate which of the eight zones is in alarm and which zones are in trouble depending on which format used Restoral from alarm or trouble signals shall also be transmitted by zone The control communicator shall be capable of communicating to Silent Knight or Ademco central station receivers Meridian Circle Maple Grove MN 55369 4927 or in Minnesota 612 493 6435 612 493 6475 Wide Web http www silentknight com IN AMERICA 350376 Rev 12 98 1998 Silent Knight

Related Files