Silent Knight 5820xlspec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-5820xlspec-3015476298.pdf |
---|---|
Type | |
Size | 822.00 KB |
Downloads |
Text Preview
INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5820XL Fire Alarm System IntelliKnight System is the easy way make the most of fire alarm 5820XL is the first fire alarm system to provide you with value and performance in addressable sensing technology 5820XL FACP offers exclusive built in digital communication intelligent power a modular design and an expanded easy to use interface Powerful features such drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight more information about the 5820XL system or to locate your nearest source please call or in Minnesota call 763 493 6435 performs drift compensation calibration checks on each of the in the system basic 5820XL system can be by adding modules such as remote annunciator 5815XL line circuit expander 5824 printer interface module printing system reports and intelligent power module also features a powerful built in line fire communicator that allows reporting of all system activity to a monitoring location Up to 508 addressable points Uses standard wire shielded or pair required Built in digital communicator Central station reporting by point or zone Built in synchronization for from AMSECO Faraday System Sensor Wheelock Flexput I O circuits Supports Class B Style 4 and Class Style 6 configuration for SLC and Flexput circuits Distributed intelligent power Drift compensation 13 pre programmed output cadences ANSI 3.41 and 4 outputs Built in annunciator with LCD display RS 485 bus provides communication system accessories Built in RS 232 and USB interface for via PC Built in Form C trouble relay rated at amps at 27.4 VDC Improvements in SKSS software five times faster Two built in Form C programmable rated at 2.5 amps at 27.4 Supports sounder bases 6 amp power supply and maximum capacity of 35 amp hours additional cabinet enclosure is for batteries in excess of 18 hours Programmable date setting for Saving Time Plex 1 door option combines a dead cabinet door with a clear limiting access to the panel providing single button of the reset and silence Specifications AC VRMS at 50 60 Hz 2.5A or VRMS at 50 60 Hz 1.4A Accessory Load 6A 27.4 VDC mA Current Current mA Circuits Six programmable which can be programmed as circuits 3A 27.4 VDC circuit power limited power circuits 3A 27.4 per circuit power limited Circuits 100 mA 27.4 per circuit power limited Specifications Mount Dimensions x 24.75 x 3.9 W x 62.9 H x 9.8 D cm 5820XL Dimensions x 26.4 x 4.2 W x 67 H x 11.8 D cm 28 lbs 12.8 kg Red Charging Capacity 7.0 35 AH Size 18 AH max allowed in panel cabinet Larger capacity can be housed in RBB cabinet Requirements Part 15 and Part 68 approved of Jack RJ31X two required FIRE ALARM CONTROL PANEL Model 5820XL Fire Alarm Control Panel Lights Alarm Red Flashes when in solid when alarm silenced Yellow Flashes when a condition exists solid when silenced Troubles Yellow Flashes a trouble condition exists solid trouble silenced Silenced Yellow On when an trouble or supervisory condition been silenced but not yet cleared Power Green Flashes for AC solid when power systems are Application has one built in signalling line SLC which supports 127 Three additional loops can be using the 5815XL SLC to increase overall capacity 508 devices 5820XL SLC loops support device types including Addressable photoelectric smoke Addressable ionization smoke Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module following advanced sensor are available with 5820XL Automatic drift compensation Maintenance alert Built in sensor test to comply with 72 calibration testing features a 6 amp power supply maximum battery charging of 35 amp hours An additional enclosure PN RBB is required batteries in excess of 18 amp hours circuits on 5820XL control can individually programmed to function notification circuits auxiliary power or initiation circuits that both 2 and 4 wire smoke 5820XL system operates on non unshielded cable when wired compliance with standard wiring as called out in the National Code 760 51 specifications for fire protective signalling No special wiring is required provides 13 preset notification patterns including ANSI 3.41 four user programmable selections fire alarm notification programmable general purpose C relay outputs are provided on the IntelliKnight system a built in walk test and auto Its innovative dead front design allows for flush or mounting System maintenance easy to perform Interface 5820XL built in annunciator with character LCD display and large tactile touchpad can be for system operation and maintenance It has LEDs for alarm supervisory trouble system silenced and power System operations silencing alarms and troubles alarms and the display of troubles and memory The non volatile event history stores 1000 events for viewing the built in or remote annunciator operation can be initiated with mechanical firefighter s key or a valid to 7 digit operator s code IntelliKnight system offers several to simplify and speed up The JumpStart feature programming to start a new system The keypad and 5860 remote give on site access to all You can also program using the 5660 Silent Knight Suite which is Windows software Digital Communicator features a built in UL listed communicator for remote of system activity and system The communicator has ability to seize two telephone lines report alarms and troubles to a facility The communicator two phone lines and will a trouble signal if a line failure sustained for more than 45 seconds communication features include if communication fails two phone capability download phone capability and Touch Tone or dialing The communicator is with SIA and Ademco ID The format is selectable by number 13 NFPA 15 NFPA 16 72 Central Station Remote Local Protective Signalling Auxiliary Protected Premises Water Deluge Releasing Suitable for automatic waterflow sprinkler DACT non coded services Approvals UL Listed 7170 0559 135 429 92 E Vol VI FM Approved FIRE ALARM CONTROL PANEL Model 5820XL Fire Alarm Control Panel FIRE ALARM CONTROL PANEL Detectors devices feature a low profile and EEprom addressing addressing prevents water problems via the back of the and eliminates mechanical related to decade switches photoelectric smoke ionization smoke detector temperature heat detector goes into alarm immediately if the exceeds the trip point Trip point from 135 inch base for use with detector SD505 APS SD505 AIS and inch base for use with detector SD505 APS SD505 AIS and sounder base for use with sensor and base Operates in and multi station modes and or a system sounder Requires 2 wires for power i