Silent Knight Analog Addressable Devices with Hochiki Protocol
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-analog-addressable-devices-with-hochiki-protocol-5749386201.pdf |
---|---|
Type | |
Size | 716.41 KB |
Downloads |
Text Preview
Hochiki SD Devices devices are intelligent ddressable devices for use with the following Silent Knight addressable fire alarm control panels FACPs 6820EVS 6808 6700 5820XL 5820XL EVS 5808 and 5700 SD modules and accessories communicate to the FACP over the line circuit loop SLC loop using a two wire connection Shielded twisted wire is not required Any combination of addressable SD devices SD modules can be used on a single SLC loop assortment of SD detectors modules and accessories that are with Honeywell Silent Knight addressable FACPs are described For detailed information on SD devices see the device specification A photoelectric smoke detector SD505 PHOTO has an light source and silicon photo diode receiving element SD505 PHOTO offers a low profile installation and the model SD505 6AB base compatible with other in the series allowing for complete application placement flexibility A fixed temerature heat detector It provides accurate measurement data to the fire alarm control panel This heat is particularly suited to environments where smoke detectors be used because of the presence of steam or cooking fumes such in a kitchen A addressable duct smoke detector that detects smoke and of combustion present in air moving through an HVAC duct This detector is housed in a heavy duty metal housing with a preinstalled smoke detector SD505 DUCT has an air velocity rating from feet per minute to 4,000 feet per minute Order SD505 T2 SD505 T5 SD505 T10 air sampling tubes separately A duct smoke detector that detects smoke and products combustion present in air moving through an HVAC duct SD505 DUCTR provides a fully programmable Form C This duct detector is housed in a heavy duty metal with a preinstalled photoelectric smoke detector relay module When smoke is detected in a duct detector communicates the condition to the FACP built in relay module then turns off fans and other devices SD505 DUCTR has an velocity rating from 300 feet per minute to feet per minute A dry contact input that acts as an interface contact devices such as switches and stations The SD500 AIM Class B supervised module monitors alarm contact closures and open circuit fault conditions Mounts in a 4 square A compact and light weight module that acts as an interface to devices such as waterflow switches and stations The SD500 MIM supports Class B wiring This module mounts in a gang box A relay module provides one relay with two C contacts rated at 30 VDC or 0.6A VAC The SD500 ARM can a wide variety of normally open or closed applications including elevator door closing fan operation and auxiliary A notification module that lets add notification circuits wherever they are on an FACP SLC loop The SD500 ANM supervised monitoring of wiring to load such as bells horns and strobes You supply power to this module near the appliance to reduce wire gauge or supply power from a main supply and control it separately by the notification modules The SD500 supports Class B and Class A wiring and all notification patterns available on the FACP BENEFITSfirealarmresources com a complete listing of all approvals and please visit Windows and Windows Logo are trademarks trademarks of Corporation Knight and are registered of Honeywell Inc document is not to be used for purposes We to keep our product up to and accurate We cover all specific or anticipate requirements All are subject change without notice Technical Support 800 446 6444 A 6 mounting base adds an output function to SD505 PHOTO and The SD505 6SB can be used as a station multi station or as a system A 6 mounting base with one Form relay contact The SD505 6RB lets you control wide variety of normally open and normally applications including elevator recall closing fan operation and auxiliary Because this relay is addressable relay device can be located at any point on SLC loop A 6 mounting base a built in isolator for and detectors the SD505 6IB is to the SLC loop a short open or fault occurring on the SLC loop is as a trouble but all SLC devices to operate SD505 6IB fits under detector base included A 6 mounting base is for use with and SD505 HEAT A 4 mounting base is for use with and SD505 HEAT Devices A two wire interface module that an FACP to interface with and monitor conventional devices This means you retrofit an existing building and use existing devices including two wire smoke and devices with dry contacts such as stations and heat detectors The SD500 transmits the status condition normal or alarm of one full zone of two wire to the FACP The SD500 SDM supports B and Class A wiring A line isolator module isolates a short circuit wiring on an SLC loop When a short on the SLC loop it is as a trouble but all of the devices protected by a SD500 LIM will to operate An LED driver module that to the SLC loop and is capable of 80 LEDs Honeywell Silent Kniht FACPs up to 40 SD500 LEDs per SLC loop The is a single action station requiring only one to activate the station SD500 PSDA is a dual pull station requiring two motions to the station Both pull stations feature a metal construction and mount in a single box A remote test switch for use with SD505 DUCTR that provides remote key test function and annunciation of alarm more information more about Honeywell Silent Knight and other by visiting Silent Knight Clintonville Road CT 06472 53624 C 05 18 2018 Honeywell International Inc