Silent Knight IDPcontrol6 spec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-idpcontrol6-spec-1467902385.pdf |
---|---|
Type | |
Size | 709.80 KB |
Downloads |
Text Preview
IDP Control 6 IDP Control 6 is an addressable notification module use with Silent Knight IFP series fire alarm control FACPs The IDP Control 6 has six integrated for maximum flexibility you to add notification circuits wherever they are on an IFP FACP signaling line circuit SLC loop IDP Control 6 provides supervised monitoring of to load devices that require an external power or amplifier tooperate such as bells horns and It is capable of supporting Class B Style Y and A Style Z wiring command from the FACP the IDP Control 6 will the supervision and connect the external power across the load device The disconnection of the provides a positive indication to the panel that control relay actually turned on The external power is always relay isolated from the SLC loop so that a condition on the power supply will never interfere the rest of the system needed you can disable a maximum of three unused on the IDP Control 6 board Each module has for connection to an external supply circuit for devices on its notification appliance circuit NAC or more multiple power supplies or amplifiers can be IDP Control 6 has a short circuit protection monitor for module The short circuit protection monitor protects power supplies against short circuit conditions on NAC In addition an algorithm is incorporated to find a when the module is active The module will close all that are not shorted to find the NAC with the solution for adding notification circuits needed 12 to 18 AWG plug in terminal blocks for Class B or Class A wiring LED for each module module mounting in the IDP ACB cabinet modules can be disabled address switches for fast installation Mounting hardware included Listed Meridian Circle Suite 100 Grove MN 55369 or 800 328 0103 763 493 6475 Notification Module IDP Control 6 mounts in the Silent IDP ACB cabinet PN IDP ACB IDP ACB has a built in chassis that will one or two IDP Control 6 IDP Control 6 is compatible with the following Information Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel input Notification Module Module Cabinet holds two 350294 Rev C Honeywell International Inc 38.7 cm 31.8 cm 7.6 cm lbs 2.8 kg 6.8 17.3 cm 5.8 14.7 cm 1.25 3 cm Weight 6.3 oz 196 g Temperature 32 120 0 49 10 93 non condensing Voltage 15 32 VDC Current 35 mA all six relays switched once and all six solid on Current 2.2 mA max Loop Resistance 40 max Circuit Wiring Resistance 40 max Rating Per Circuit 63W 70.7 VAC 50W 25 VAC Contact Ratings 30 VDC resistive noncoded 30 VDC resistive coded 110 VDC resistive noncoded 125 VDC resistive noncoded 30 VDC inductive L R 5 ms coded 30 VDC inductive L R 2 ms coded 125 VAC inductive PF 0.35 noncoded 25 VAC inductive PF 0.35 noncoded 70.7 VAC inductive PF 0.35 noncoded 25 VAC inductive PF 0.35 noncoded document is not intended to be used for installation purpose We try to keep our product up to date and accurate We cannot cover all specific applications or handicapped all All specifications are subject to change without notice For more information Silent Knight 7550 Meridian Circle Suite 100 Maple Grove MN 55369 800 328 0103 fax 763 493 6475 In USA