Silent Knight IDPrelay isheet

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-idprelay-isheet-0465813729.pdf
Type PDF
Size 702.46 KB
Downloads

Text Preview

Mounting IDP Relay mounts directly to 4 square electrical see Figure 2A The box must have a mini depth of 21 8 Surface mounted electrical boxes are available from Silent Knight All wiring must conform to applicable local ordinances and regulations When using control in nonpower limited applications the CB500 Barrier must be used to meet UL requirements the separation of power limited and nonpower limited and wiring The barrier must be inserted into a 4 21 8 junction box and the control module must placed into the barrier and attached to the junction box 2A The power limited wiring must be placed into isolated quadrant of the module barrier Figure 2B Install module wiring in accordance with the job draw and appropriate wiring diagrams Set the address on the module per job drawings Secure module to electrical box supplied by installer shown in Figure 2A 1 Controls and indicators 865 6 7 8 9 2A Module mounting with barrier 2B AND INSTRUCTIONS Operating Voltage Current Draw Operating Current 255 Resistance Range to 32 VDC mA LED on used to 120 0 to 49 to 93 non condensing H x 4 W x 11 4 D to a 4 square 21 8 deep box Electrical Box Installing information is included as a quick reference in guide Refer to the appropriate Silent Knight panel installation manual for detailed system If the modules will be installed in an exist operational system inform the operator and local au that the system will be temporarily out of service power to the control panel before installing modules This manual should be left with the owner of this equipment Description IDP Relay is intended for use in intelligent two wire where the individual address of each module is using the built in rotary switches It allows a control panel to switch discrete contacts by command The relay contains two isolated sets of contacts which operate as a DPDT switch and rated in accordance with the table in the manual connections to the relay contacts are not super by the module The module also has a panel con LED indicator Requirements ensure proper operation this module shall be con to a compatible Silent Knight system control panel available from Silent Knight Contact Ratings RATING MAXIMUM VOLTAGE DESCRIPTION A A A A A A A A A A VDC VDC VDC VDC VDC VDC VAC VAC VAC VAC L R 5ms L R 2ms PF 35 PF 35 PF 35 PF 35 relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed during shipping To ensure that the switch contacts are in their correct state modules must be made to communi with the panel before connecting circuits controlled by the module 3 Relay module wiring diagram LINE CIRCUIT SLC VDC Max PAIR RECOMMENDED MODULES TO LISTED COMPATIBLE PANELS ONLY PANEL OR DEVICE NEXT COMMON 2 CLOSED 2 OPEN 2 COMMON 1 CLOSED 1 OPEN 1 ANY WIRING TO TERMINALS 3 9 IS NONPOWER THE CB500 BARRIER IS REQUIRED THE CB500 A NONPOWER LABEL WHICH MUST PLACED OVER THE POWER LIMITED TERMINAL ON THE NAMEPLATE LABEL MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS Meridian Circle Grove MN 55369 4927 800 328 0103 763 493 6475 2006 Silent Knight

Related Files