Silent Knight IDPrelay6 isheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-idprelay6-isheet-8576214093.pdf |
---|---|
Type | |
Size | 712.38 KB |
Downloads |
Text Preview
ground yourself with a proper wrist strap before handling circuits so that static charges are removed from the The housing cabinet should be metallic and suit grounded This manual should be left with the owner of this equipment DESCRIPTION IDP Relay 6 Six Relay Control Module is intended use in an intelligent alarm system Each module is for Form C switching applications which do require wiring supervision for the load circuit A isolated set of dry relay contacts is provided for module which is capable of being wired for either open or normally closed for each operation module has its own address A pair of rotary code is used to set the address of the first module 01 to 94 The remaining modules are automatically to the next five higher addresses Provisions are for disabling a maximum of three unused mod to release the addresses to be used elsewhere Each module also has panel controlled green LED The panel can cause the LEDs to blink latch or latch off include 1 3 Terminal Blocks 1 4 Terminal Blocks 11 4 32mm Stand offs Machine Screws Nuts Shunt NOTE For the disable position not more one shunt shall be installed at the same time REQUIREMENTS ensure proper operation this module shall be connected a compatible Silent Knight system control panel AND INSTRUCTIONS Relay Control Module mA mA assumes all six relays been switched once and six LEDs solid on to 120 0 to 49 to 85 Non condensing H 5.8 W 1.0 D Operating Voltage 15 32 VDC Stand By Current Range IDC Resistance Gauge Current INSTALLING the modules will be installed in an existing operational inform the operator and local authority that the will be temporarily out of service Disconnect the to the control panel before installing the modules system contains static sensitive components Always ohms cabinet and chassis AWG mA Relay Pulse 15.6 pulse duration pulse panel control RATING VOLTAGE DESCRIPTION A A A A A A A A A A VDC VDC VDC VDC VDC VDC VAC VAC VAC VAC L R 5ms L R 2ms PF 35 PF 35 PF 35 PF 35 relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed during shipping To ensure that the switch contacts are in their correct state modules must be made to communi with the panel before connecting circuits controlled by the module following is a description of the IDP Relay 6 mount framework One or two IDP Relay 6 modules can be installed in a IDP ACB cabinet IDP ACB cabinet has a built in chassis that will ac one or two IDP Relay 6 modules 1 IDP ACB Cabinet front IDP Relay 6 module positions of each chassis offset below the rear IDP Relay 6 module positions that all of the status indicators are visible For cabinet refer to IDP ACB instruction manual STEPS Cabinet Mounting a clean dry area mount the backbox using the four provided in the back surface of the cabinet 3 Installation of rear module only method one 1 Insert the bottom of the IDP Relay 6 module into a rear slot on the chassis 2 Carefully swing the upper edge of the board towards the back of the chassis until it the two standoffs 3 Align two 4 40 screws with the two standoffs tighten 4 Address and wire the modules according to the in this manual steps in Figures 4a and 4b describe and illustrate mod installation when the rear chassis position and the posi in front of it will be filled Front position installation possible only if the rear position is filled with a module 2 Typical mounting hole locations Module Installation There are two methods for installing a module in the position of a chassis Method one is for installa of a rear module only when no module will be in in front of it Refer to Figure 3 for instructions two is for installation of a rear module when module will be installed in the chassis position front of it Refer to Figures 4a and 4b for method All necessary screws and standoffs are supplied the modules 4a Installation of IDP Relay 6 module in a chassis position method two 1 Insert the bottom edge of the IDP Relay 6 down into a rear slot of the chassis 2 Carefully swing the bottom edge of the board the back of the board until it touches the standoff attached to the chassis 3 Align the long standoff with the short standoff tighten The relay contacts on the IDP Relay 6 may be connected to either a power limited or non power limited source this wiring must remain separated by at least 1 4 6.35 mm from all power limited wiring Power limited circuits must employ type FPL FPLR or FPLP cable as required by Article 760 of the NEC For easier wiring assign all power limited wiring to one side rather than alternating with non power limited modules are programmed as modules in each system to the programming instructions in the appro FACP manual 4b Installation of IDP Relay 6 module in chassis position 1 Insert the bottom edge of the IDP Relay 6 down into a front slot of the chassis 2 Carefully swing the upper edge of the board the back of the chassis until it touches 11 4 31.75mm standoffs installed on the module 3 Align two 4 40 screws with the two standoffs and tighten 4 Address and wire the modules according to instructions in this manual All wiring must conform to applicable local ordinances and regulations Install module wiring in accordance with the job draw and appropriate wiring diagrams Make electrical connections by stripping approxi 1 4 6.35mm of insulation from the end of the sliding the bare end of the wire under the clamp plate and tightening the clamping plate screw Set the address on the modules per the job drawing the rotary code switches to set the address of the module between 01 and 94 The remaining mod are automatically assigned to the next five higher For example if the base address switch is to 28 the next five modules will be addressed to 30 31 32 and 33 DO NOT set the lowest address 94 as the other modules will be assigned to addresses A shunt is provided to disable a maximum of three modules Modules are disabled from the high address and work downward If two modules are the lowest four addresses will be functional the highest two will be disabled For example if shunt for Address Disable is placed on and base address switch is set to 28 the modules will assigned to 28 29 30 and 31 The IDP Relay 6 must have power cycled for changes to take effect PANEL PREVIOUS DEVICE LINE CIRCUIT SLC VDC MAX PANEL INSTRUCTION FOR REQUIREMENTS NEXT A A A A A