Silent Knight SD500-SDM Smoke Detector Module Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-sd500-sdm-smoke-detector-module-manual-9827156043.pdf |
---|---|
Type | |
Size | 1.00 MB |
Downloads |
Text Preview
Installation SD500 SDM two wire smoke module you to connect a loop of conventional to a Silent Knight addressable fire control panel FACP Each loop can then assigned an address on the FACP Parameter Smoke Detector Current Voltage Current for battery Temperature Power SLC Loop Resistance 2 wire Conventional Smoke Loop mA max mA max VDC VDC mA mA 120 F 49 C RH indoor use only SD500 SDM is compatible with all Silent addressable FACPs and wiring of this device must be done in with NFPA 72 and local ordinances All wiring is supervised and power limited the SD500 SDM the SLC Loop SD500 SDM connections to the 5815XL and external are the same Wire as in Figure 1 1 SLC Wiring Detector Connections section contain instructions on how to a 2 wire conventional smoke detector to the SD500 SDM for either Class B Style or Class A Style D 151193 Installation Instructions B Style B Wiring Class B Style B conventional smoke loop to the SD500 SDM as shown in 2 Place the jumper block in the Class B B supervision position see Figure 4 Power Using Circuits SD500 SDM can use aux power from any VDC source The following describes how to the Flexput circuits as the auxiliary power Connect the aux power wires to the Flexput using terminals as positive terminals as negative power See 5 2 Class B Style B 2 Wire Detector Loop Auxiliary power is supplied by a Regulated UL listed supply for Fire Protective Signalling Systems A Style D Wiring Class A Style D conventional smoke loop to the SD500 SDM as shown in 3 Place the jumper block in the Class A D supervision position see Figure 4 3 Class A Style D 2 Wire Detector Loop 5 Flexput Auxiliary Power Output Configure the auxiliary power output for output through programming Refer the FACP installation manual form more More Information document is for quick reference For more refer to the FACP installation 4 Supervision Selection Jumper 151193 Installation Instructions Smoke Detectors 1 lists two wire smoke detectors that are compatible with the fire control panel The table is by manufacturer The columns show the number of detectors per loop that can be used Voltage Range VDC The maximum number of smoke detectors per zone is determined by both the current draw and the impedance of the smoke If too many smoke detectors are used on any zone false alarms could occur not mix different models of detectors on any zone false alarms could occur not mix detectors of different models unless the system is specifically intended to be installed in that configuration unit Smoke Reset Time must be programmed for a number greater than or equal to the maximum reset time of the smoke 1 Compatible Two Wire Smoke Detectors Name or Number model name or number in ID per Loop 151193 45681 200 45681 200 S10A S11A S11A S10A 601U or 602U 601U or 602U 601U or 602U 601U or 602U 601U or 602U 701E or 701U 701E or 701U 702E or 701U 702E or 701U S10A S10A loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop Installation Instructions Sensor 1 Compatible Two Wire Smoke Detectors Name or Number model name or number in ID per Loop HS 224D OR HSD 224 HD 3 HS 224D HS 224D B401B DH400 B401B DH 400 B401B loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop loop 2007 Honeywell International Inc PN 151193 Rev D Meridian Circle Grove MN 55369 4927 or 800 328 0103 763 493 6475