Silent Knight SK-IP-2 SK-IP-2U IP Fire Alarm Communicators
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-sk-ip-2-sk-ip-2u-ip-fire-alarm-communicators-6073521894.pdf |
---|---|
Type | |
Size | 750.04 KB |
Downloads |
Text Preview
INTELLIKNIGHT IP FIRE ALARM COMMUNICATOR Models Fire Alarm Communicators IntelliKnight IP Communicators and an Ethernet connection simply replace the telephone lines as the communications path to the central station It connects to customer supplied network equipment with a to the Internet The communicators provide supervised telephone line voltage to both panel DACT Upon network communication loss telephone line voltage is dropped to the panel and panel reports loss trouble The communicators monitor the connectivity to both the primary and secondary at the central station For more information about this panel and other Silent Knight products please call new IntelliKnight SK IP 2 and SK IP 2UD are IP communi UL listed for monitoring of Silent Knight fire alarm compatibility table The SK IP 2 has two supervised and two additional outputs The SK IP 2UD version 6.0 adds modem daughter board 2UD that supports upload download the Internet or a customer Intranet for IntelliKnight models and 5808 FACP These IP Communicators are UL 864 for signaling under Other Transmission Technologies and with NFPA 72 requirements Refer to the IP Communicator Installation Document PN 53109 for more information models connect to the primary and secondary communication of the panel DACT converting the analog signals into digital at the panel for transmission to a compatible Teldat PLUS IP receiver at a central station The panel normally during an alarm supervisory or trouble event sends contact ID formatted analog information out of the ports to the IP Communicator The IP Communicator the data into highly encrypted Ethernet UDP packets for to a compatible receiver at the central station This listing only requires an IP connection No backup analog line is necessary to work with compatible Contact ID DACT equipped panels from Silent Knight the IP Communicators for faster and more economic digital alarm transmissions response times and decreasing costs found with analog systems They offer value added features such supervised line functionality where a central station can detect off line alarm panels within seconds On the central station a compatible VisorALARM Plus IP receiver from the Teldat allows seamless integration into existing conventional station architectures benefit of an IP Communicator is that it is always on the security and supervision of the central station from once every 24 hours for a supervisory test signal once every 30 90 seconds SK IP 2UD allows a programmer to upload and download data the user PC and either the IntelliKnight 5808 or 5820XL FACP The panel and PC can be anywhere on the wide web or within a corporate intranet user computer runs a program called UDPORT exe to the modem signals from or the newer PS TOOLS panel software In UDPORT exe the user enters the main address of the Communicator receiver the UDP port to use username password Instead of using the PC modem this communicates between the SK IP 2UD at the panel and the panel own modem speed is still limited to the baud rate of the modem panel communications are now 100 over IP from the remote program PC all the way the remote panel installation This eliminates any in modem communications caused by noise other factors If an alarm should occur during upload download the panel is able to interrupt modem immediately and transmit the alarm to central station SK IP 2UD is registered in the VisorALARM with a unique serial number A subscriber must be entered into the subscriber number field for each SK IP 2UD This same number entered into the subscriber telephone number field to call in PK PLUS or PS TOOLS as if calling panel on a telephone If these numbers match and master username and password are correct full communication is permitted to the panel UL 864 Ninth Edition prohibits downloading to panel without entering a local panel password is permitted at any time without a password IP FIRE ALARM COMMUNICATOR Model SK IP 2 2UD Fire Alarm Communicator Listed to UL Standard 864 Eliminates the cost of two dedicated phone lines Only the shared IP equipment is required Can use newer low cost non analog digital telephone such as cable or fiber optics connection supervision to the central station the once a day test signal to once every 30 90 Requires no change to the existing panel configuration IP Communicator connects directly to the primary and analog panel telephone ports Fast alarm transmission less than 10 second time Works over any type of customer provided Ethernet Base network connection LAN or WAN DSL or cable modem Data transmits over standard contact ID protocol but is with the industry highest level of encryption 512 bit Supports both dynamic DHCP or Public and Private IP addressing Supports dual destination IP receiver address for high configurations all signals are sent to a address should the primary become User programmable UDP ports for flexibility and compati with firewalls and other network security components Supports an optional third maintenance receiver installed the end user facility that permits local alarm Alarms are received simultaneously at both the station and the customer facility A filter can be to annunciate specific alarm types such as events Supports upload download using existing familiar tools Two supervised inputs and two outputs RJ45X Ethernet Termination to Program are three ways to configure the IP Communicator Console terminal using the HyperTerminal software found on all Microsoft operating systems Local or remote Telnet session via Ethernet connection Windows based configuration software shipped with IP or downloaded from IP Communicator can be pre programmed The enters all central station information and an password This is saved to the unit flash When the IP Communicator is installed at the site connected to the Internet Intranet it registers itself with central station receiver This eliminates the need for a at the remote site for programming The IP receiver at monitoring station will automatically configure other during registration most installations the only required parameters are Selection of either DHCP or Static IP Destination primary and secondary receiver IP addresses Account identification number CID Port number of these parameters are assigned by the central station Requirements for full details password IP Communicator is compatible with the following Silent panels non upload download 5820XL 5808 5700 SK5208 5104B 5600 with Upload Download 5820XL 5808 PLUS IP Receiver FireWatch IP Communicator reports to the IP receiver manufactured by the Teldat Each IP receiver can manage up to 3,000 IP accounts and is compatible with existing station alarm monitoring software VisorALARM IP receiver is based on high availability technology and uses a high performance embedded system for higher reliability and efficiency All IP configuration and operating data is backed up to a card This allows for an immediate equipment within 60 seconds with almost no downtime and information loss The Primary and Secondary receiver provide maximum level of redundancy and can be backed up by additional receivers for highest reliability available in the industry Both receivers in real time over the network to keep synchronized and up to date Each VisorALARM Receiver can handle up to 20 concurrent TCP IP from Upload Download Users IP FIRE ALARM COMMUNICATOR Model SK IP 2 2UD Fire Alarm Communicator Requirements following are required for proper installation of the IP 24 VDC non resettable filtered regulated power SK IP 2UD 155 mA in alarm standby 98 mA