Silent Knight SK-Monitor-2 Addressable Dual Input Monitor Module Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-sk-monitor-2-addressable-dual-input-monitor-module-manual-3905647281.pdf |
---|---|
Type | |
Size | 914.83 KB |
Downloads |
Text Preview
I Clintonville Road Northford CT 06472 1610 203 484 7161 Fax 203 484 7118 directly to 4 inch square electrical boxes see Figure 2 The box have a minimum depth of 21 8 inches Surface mounted electrical boxes are available from Silent Knight 2A MODULE MOUNTING AND MAINTENANCE INSTRUCTIONS Monitor Module Operating Voltage Current Draw Operating Current SLC wiring Resistance Resistance IDC wiring resistance IDC Voltage IDC Current Range INSTALLING information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules to 32 VDC mA LED on LED flashing k Volts to 120 0 to 49 to 93 Non condensing H x 4 W x 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box This manual should be left with the owner user of this equipment DESCRIPTION Dual Monitor Module is intended for use in intelligent two wire systems provides two independent 2 wire initiating device circuits IDC at two sep consecutive addresses It is capable of monitoring normally open con fire alarm and supervisory devices or either normally open or normally security devices The module has a single panel controlled red LED REQUIREMENTS ensure proper operation this module shall be connected to a compatible Knight system control panel list available from Silent Knight 1 CONTROLS AND INDICATORS All wiring must conform to applicable local codes ordinances and This module is intended for power limited wiring only Install module wiring in accordance with the job drawings and appropri wiring diagrams the address on the module per job drawings NOTE Monitor module L using terminals 6 and 7 responds at the ad set on the code switches Monitor module H using terminals 8 and will automatically respond at the next higher address For example if code switches are set to 76 module L will respond at address 76 and H will respond at address 77 Use caution to avoid duplicate ad of modules on the system Secure module to electrical box supplied by installer as shown in 2 All references to power limited represent Limited Class 2 3 TYPICAL 2 WIRE INITIATING CIRCUIT CONFIGURATION NFPA STYLE B INITIATING DEVICE CIRCUITS L H EACH LIMITED TO 240 mA 11 VDC MAX NEXT PANEL OR DEVICE 47k EOL 47k EOL MODULES TO LISTED CONTROL PANELS ONLY LINE CIRCUIT SLC VDC MAX SHIELDED TWISTED IS RECOMMENDED LISTED CONTACT CLOSURE DEVICES MAY USED DO NOT MIX FIRE ALARM INITIATING OR SECURITY DEVICES ON THE INITIATING DEVICE CIRCUIT CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS WIRING SHOWN IS AND POWER LIMITED L TERMINALS 6 7 RESPONDS AT ADDRESS ON CODE SWITCHES MONITOR H TERMINALS 8 RESPONDS AT NEXT HIGHER ADDRESS Knight System Sensor and Honeywell are registered trademarks of Honeywell International Inc Honeywell 04 12