Silent Knight WSK-PULL-DA Instruction Manual

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-wsk-pull-da-instruction-manual-9708452631.pdf
Type PDF
Size 2.11 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Clintonville Road Northford CT 06472 1610 Clintonville Road Northford CT 06472 1610 203 484 7161 Fax 203 484 7118 203 484 7161 Fax 203 484 7118 Wireless Pull Station Operating Voltage Current Draw Operating Current Transmit RF Power Frequency Range Range Type Life Replacement VDC mA LED on dBm MHz to 120 0 to 49 to 93 Non condensing Panasonic CR123A or 4 Duracell DL123A year minimum TROUBLE BATTERY LOW display and or during annual maintenance 142 mm H x 4.2 107 mm W x 2.1 53 mm D Cartridge W BATCART INSTALLING pull station must be installed in compliance with the control panel sys installation manual the SWIFT Wireless Gateway Manual applicable standards national and local Fire codes and the requirements of the Authority Having Jurisdiction Regular testing of the devices should be in accordance with the appropriate NFPA standards Pull stations offer performance when installed in compliance with the National Fire Association NFPA see NFPA 72 This manual should be left with the owner user of this equipment DESCRIPTION WSK PULL DA wireless addressable pull station is a UL38 compliant manual pull station with a key lock reset feature intended for with a wireless gateway or wireless fire alarm control panel FACP See 1 It provides Silent Knight panels one addressable alarm initiating in The device communicates through a robust bi directional mesh network the gateway and or FACP Rotary dial switches are provided for setting the station address See Figure 2 Operating instructions are molded into pull station handle along with Braille text The wireless pull station meets Americans with Disabilities Act Accessibility Guidelines ADAAG controls operating mechanisms guidelines section 4.1.3 13 the Americans with Act ADA requirement for a 5 lb maximum pull force to activate pull station and conforms to ANSI UL Standard 38 offer different feature sets across the various models As a result cer features may be available on some control panels but not on others The feature sets available with the wireless pull station include An LED on the wireless pull station is controlled by the panel to indicate status Operational modes include red green and amber colors in solid or blink patterns REQUIREMENTS ensure proper operation this module shall be connected to a compatible Knight system control panel list available from Silent Knight 1 WIRELESS MANUAL PULL STATION DOOR battery door includes a magnet for activation and tamper resistance See 2 The battery door magnet activates communication to the panel the battery door must be installed and closed for the pull station work properly The magnet also activates a tamper fault at the panel if the door is opened Do NOT remove this magnet REPLACEMENT battery levels on the wireless devices are displayed as a trouble in the Therefore when the message BATTERY LOW is displayed the battery in the device This message is an indication that approxi one week of battery life remains replace the batteries in a wireless device use the following steps Have 4 CR123A or DL123A batteries available Use the key to unlock and open the pull station door Open the battery compartment See Figure 2 Remove the used batteries and replace with new batteries Batteries can be directly into the pull station or inserted as a set of 4 batteries pre in a battery cartridge available from Silent Knight See Figure 2 battery compartment and cartridge indicate the correct orientation of batteries Carefully align the batteries with these markings and do not them into place Close the battery compartment cover Close and lock the pull station door 2 BATTERY INSTALLATION Compartment With Door Open Compartment Door in the Closed Up Position Compartment Door in the Open Down Position Address Switches Cartridge technologies can exhibit communication disruption if devices are too close together To avoid this form of disruption SWIFT devices not be placed closer than 2 feet 60 cm apart without an intervening For specific information regarding pull station placement refer to 72 ADAAG and ADA mount the wireless pull station attach the wireless pull station mounting to a permanent structure The mounting plate can be surface mounted avoid interference with the wireless network metal electrical boxes are NOT Do not detach the door of the pull station during installation door of the pull station cannot be reattached to the main housing after the station has been installed Place the pull station onto the mounting plate secure by tightening all three 3 mounting screws inside the door of the housing using a 1 Phillips head screwdriver See Figure 3 Do not attach the pull station to temporary structures such that the could be altered 3 DEVICE MOUNTING activate the dual action pull station in and pull down on the handle The word appears after handle is pulled down This will remain until the pull sta tion is reset reset the pull station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the posi Open ing the door will not activate or deactivate the alarm switch of these products in combination with non Honeywell products in a wireless mesh network or to access monitor or control devices in a wireless mesh nework via the internet another external wide area network may require a separate license from Sipco LLC For more information contact Sipco LLC or Ipco LLC at 8215 Roswell Rd Building 900 950 Atlanta GA 303350 or at www sipocollc com or www intusiq com STATEMENT STATEMENT device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation Knight and SWIFT are registered trademarks of Honeywell International Inc Silent Knight 11 06 2017

Related Files