Simplex 4090-9001 IDNet Supervised IAM Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4090-9001-idnet-supervised-iam-installation-instructions-7812649305.pdf |
---|---|
Type | |
Size | 1.03 MB |
Downloads |
Text Preview
Installing the Supervised IAM the Supervised IAM into a UL Listed single gang 4 inch square or 4 inch octagonal electrical box supplied using Figure 4 as a reference Mount the Supervised IAM to the electrical box as follows the Supervised IAM into the electrical box the attached field wiring holds the Supervised IAM place inside the electrical box Secure the cover to the back box using the two 6 32 flathead screws Wiring Listed Box Supplied Supplied Flathead Screw Supplied IAM Simplex offers semi flush and surface covers ordered separately with a light pipe The cover s light pipe allow viewing of the communications LED without taking the cover off Installation the 4090 9806 semi flush cover and 4090 9807 surface cover are detailed in publication 4090 Semi Flush Surface Covers and IAM Bracket Installation Instruction 574 796 4 Supervised IAM Back Box Installation Supervised IAM Instructions and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking Simplex product inspect the contents of the carton for shipping damage If damage is apparent file a claim with the carrier and notify Simplex HAZARD Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Ground yourself before opening or components 4090 9001 Supervised Individual Addressable Module IAM provide four state status information OPEN CURRENT LIMITED and SHORT to the 4010 Fire Alarm Control Panel FACP the IDNet channel The IDNet channel provides the communication link between Supervised IAM 4010 FACP and powers the entire IAM circuitry A typical application for this module would be to a waterflow switch II 4090 9001 Supervised IAM provides three state status information NORMAL OPEN and ALARM the host FACP via the MAPNET II channel Applications that require current limit sensing are not with MAPNET II channels Tamper Waterflow on the same IAM Manual release abort etc MAPNET II channel provides the communication link between the Supervised IAM and host 4100 or or 4020 FACP and powers the entire IAM circuitry IAM installation consists of the following Setting the Supervised IAMs address Making electrical connections to the Supervised IAM Mechanically installing the Supervised IAM Switch Re sealable Label View View The LED flashes approximately once every three seconds to indicate valid with the FACP 1 Supervised IAM Installation E 2000 Simplex Time Recorder Co Westminster MA 01441 0001 specifications and other information shown were current as of publication and are subject to change without notice is a trademark of the Simplex Time Recorder Company II Communication Net is protected by U S Patent No 4,796,025 E the Supervised IAMs Address The IDNet channel 4010 FACP only supports address codes 1 through 250 The MAPNET II channel or 4120 or 4020 FACP supports address codes 1 through 127 Supervised IAM has a unique address The address of the IAM is set via an eight position DIP switch 1 DIP switch position 1 is the least significant bit LSB and position 8 is the most significant bit Set the IAMs address using Figure 2 as reference Use a small screwdriver or pen to set the switches device address for the Supervised IAM should be written on the re sealable label this information provides aid in troubleshooting the system DIP switch in position is while DIP switch in position is IS SHOWN SET AT ADDRESS 7 ON OFF SWITCHES 5 THRU 8 1000 0100 1100 0010 1010 0110 1110 0001 1001 0101 1101 0011 1011 0111 1111 128 144 160 176 192 208 224 240 129 145 161 177 193 209 225 241 130 146 162 178 194 210 226 242 131 147 163 179 195 211 227 243 116 132 148 164 180 196 212 228 244 117 133 149 165 181 197 213 229 245 118 134 150 166 182 198 214 230 246 119 135 151 167 183 199 215 231 247 120 136 152 168 184 200 216 232 248 121 137 153 169 185 201 217 233 249 122 138 154 170 186 202 218 234 250 123 139 155 171 187 203 219 235 124 140 156 172 188 204 220 236 125 141 157 173 189 205 221 237 126 142 158 174 190 206 222 238 127 143 159 175 191 207 223 239 II supports address codes 1 through 127 only 2 Supervised IAM Address Chart FACP IDNet Channel the Supervised IAM to the 4010 panel using the 4010 Fire Alarm Installation and Programming and 4010 Fire Alarm Installing Operating and Programming Instructions 574 052 Refer to panel label 526 444 for appropriate revision of the instructions to be used FACP MAPNET II Channel the Supervised IAM to the host FACP using the 4100 4120 or 4020 Programmer Report The IAM address and location must match up with the address listed in the specification sheets of the 4120 or 4020 Programmer Report Electrical Connections to the Supervised IAM and output signals connect to the Supervised IAM via the terminals 1 4 as illustrated in 1 Terminal connections for the IAM are illustrated in Figure 3 Do not loop wire under terminals Break wire runs to provide supervision II IDNET Next Device II IDNET Notes Note 5 Note 4 When connecting two wires to one terminal position one wire on each side of the terminal screw Maximum allowable run from FACP to farthest device not to exceed 2500 feet Maximum total wire and MAPNET II lines are 18 AWG twisted pair shield recommended all T Taps from FACP is 10000 feet Maximum wire length is 400 feet 18 AWG Refer to Field Wiring Diagram 842 073 for further information on wiring Supervised IAMs to IDNet to Field Wiring Diagrams 841 804 or 841 996 for further information on wiring Supervised to MAPNET II IDNet and MAPNET II wiring are supervised and power limited 3 Supervised IAM Connections