Simplex 4098-9685, -9686, -9688, -9755, -9756 Duct Detector Sensor Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-9685-9686-9688-9755-9756-duct-detector-sensor-installation-instructions-3298146075.pdf |
---|---|
Type | |
Size | 1.33 MB |
Downloads |
Text Preview
4098 9685 9686 9688 9755 9756 Detector Sensor Instructions C Page and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a with the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore handle follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times DEVICES ARE DUCT SMOKE DETECTOR SENSORS THEY ARE DESIGNED TO THE AIR FLOW PASSING BY IT IN THE AIR DUCT TO DETERMINE WHETHER IT UNACCEPTABLE LEVELS OF SMOKE EFFECTIVENESS OF A DUCT SMOKE DETECTOR SENSOR IS HIGHLY DEPENDENT THE DESIGN AND OPERATING CONDITIONS OF THE AIR HANDLING SYSTEM IN IT IS INSTALLED VARIABLES SUCH AS SMOKE DILUTION AND STRATIFICATION OVER WHICH EVEN BEST DESIGNED SYSTEMS HAVE NO CONTROL AND PROPER PLACEMENT AND POSITIONING OF THE DUCT SMOKE DETECTOR SENSOR IS OFTEN COMPROMISED FOR PRACTICAL REASONS THE REASONS STATED ABOVE THE EFFECTIVENESS OF THIS DUCT SMOKE CANNOT BE WARRANTEED OR GUARANTEED UNDER NO SHOULD THIS DUCT SMOKE DETECTOR SENSOR BE USED AS OR TO BE A SUBSTITUTE FOR THE BUILDING REGULAR FIRE ALARM AND SYSTEM TO WHICH THIS DEVICE IS ATTACHED AS A SECONDARY DETECTION NFPA STATES THAT DUCT SMOKE DETECTORS SENSORS MUST NOT BE USED AS FOR OPEN AREA PROTECTION THE DUCT SMOKE DETECTORS SENSORS INTENDED FOR USE IN THE CONTROL OF AIR HANDLING EQUIPMENT FOR THE OF CLOSING DAMPERS OR SHUTTING DOWN AIR HANDLING UNITS FOR CANADIAN APPLICATION DUCT SMOKE DETECTORS AND SENSORS DESCRIBED IN THIS INSTALLATION CAN ONLY BE CONNECTED TO THE 2120 SYSTEMS THAT WERE LABLED PRIOR THE EFFECTIVE DATE OF THE CURRENT ULC STANDARD FOR CONTROL UNITS MARCH 31 AND SUBJECT TO ACCEPTANCE BY THE AHJ Page of Contents of Contents iii Description 1 1 the Duct Sensor Address 3 Duct Sensors 4098 9755 or 4098 9756 MAPNET II IDNet 3 3 Setting for the 2120 CDT System use with 4098 9755 only 3 Setting for the 4010 4020 4100 or 4120 3 Specifications 6 6 Duct Sensors 6 Duct Sensor Compatibility 6 Duct Detectors 9 Duct Detector Compatibility 10 11 15 Routines 15 to Follow 15 Detector Sensor Installation 16 Procedures 19 Installation 19 Replacement 20 Operation Detector Testing 20 Air Test 20 Test for Detectors and Sensors 21 Method of Testing Smoke Detectors Sensors 22 Operation Detector Sensor Testing 23 Differential Pressure Test 24 24 or following an 8 digit Product ID number denotes ULC listed product II Communication Net is protected by U S Patent No 4,796,025 is a trademark of the Simplex Time Recorder Company Analog Detection is protected by U S Patent No 5,155,468 Detector Base is protected by U S Patent No 5,173,683 Simplex Time Recorder Company Westminster MA 01441 0001 U S A Simplex International Time Equipment Co Ltd Mississauga Ontario L4V 1H3 Canada specifications and other information shown were current as of publication and are subject to change without notice PAGE Description 4098 Duct Detector Sensors see Figure 1 are designed to sample air and smoke in air ducts The 4098 Duct Detector Sensors are available in the configurations Two Wire Duct Detector supplied with the 4098 9601 Detector Four Wire Duct Detector supplied with the 4098 9601 Detector Two Wire Duct Detector with Relay Drive supplied with the Photoelectric Detector Two Wire Duct Sensor supplied with the 4098 9714 Photo Sensor Four Wire Duct Sensor supplied with the 4098 9714 Photo Sensor 4098 9685 4098 9686 and 4098 9688 Duct Detectors have a red LED on detector for ON indication red LED flashing or for red LED steady 4098 9755 and 4098 9756 Duct Sensors have a red LED on the PCB for ON indication red LED flashing or for or indication red LED Steady 4098 9686 Four Wire Duct Detector and 4098 9756 Four Wire Duct have a yellow LED that indicates an short or open condition on the control zone yellow LED steady a trouble is also reported to panel during a short or open condition 4098 9686 and 4098 9756 provide a supervised control circuit to drive up fifteen 15 remote 4098 9843 re