Simplex 4098-9757 QuickConnect2 TrueAlarm Sensor for use with 4098-9788 base (B) (C)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-9757-quickconnect2-truealarm-sensor-for-use-with-4098-9788-base-b-c-8073452619.pdf |
---|---|
Type | |
Size | 781.23 KB |
Downloads |
Text Preview
ULC Listed FM CSFM MEA NYC Approved TrueAlarm Analog Sensing QuickConnect2 TrueAlarm Analog Photoelectric for Model 4010 Fire Alarm Control Panels Model 4098 9757 QuickConnect2 sensor design TrueAlarm photoelectric analog sensing and two wire addressable communications into one assembly Quick and easy connection to a 4098 9788 base ordered separately Operation is for use with Simplex model Addressable Fire Alarm Control Panel UL listed to Standard 268 sensors communicate to the 4010 Panel to provide the following TrueAlert sensing operation features Smoke sensitivity that is accurately maintained at selected level of 2.5 3.0 or 3.7 ft obscuration Sensitivity monitoring that satisfies NFPA 72 testing requirements Automatic environmental compensation Automatic once per minute individual sensor check verifies sensor integrity Ability to display and print detailed sensor in plain English language magnetic test feature that activates alarm Tracking of excessive dirt accumulation base provides stationary wiring and quick snap in sensor connections Mounting is on a 4 square 4 octagonal or single box supplied separately 4098 9832 Adapter Plate is available for retrofit certain mounting methods refer to page 2 functional and architecturally styled enclosure Louvered design enhances smoke capture by flow to chamber Entrance areas are minimally visible when ceiling Chamber is easily accessible for cleaning red LED with red lens indicates Power on when pulsing Alarm or Trouble when on a remote LED is not supported Refer to data sheet S4098 0019 for sensor bases support remote LED connections QuickConnect2 TrueAlarm Sensor in 4098 9788 Base its many features the Simplex model 4010 Fire Alarm Control Panel fully supports analog sensors and IDNet addressable However for applications that only require basic features the 4010 also supports the QuickConnect2 sensor to provide addressable sensing in a compact and cost effective package 4010 panel monitors and maintains the selected of the 4098 9757 as well as providing compensation for environmental conditions as dust dirt and component degradation and full data capture for each sensor Mounting Wiring connections are to a 4098 9788 base which provides a secure and connection for the 4098 9757 sensor All sensor communications electronics are contained in the sensor assembly Alarm and Trouble LED Indication The control panel also determines when individual need cleaning Dirty sensors or other sensor will automatically be annunciated at the control and that sensor LED will light steadily In an condition the alarmed sensor LED will light LED operation is controlled by the panel system alarm a sensor LED that was lit to trouble may return to pulsing to conserve power as long as it is not in alarm This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest TrueAlarm analog sensors and bases and IDNet communications are protected by one more of the following U S Patents 5,155,468 5,173,683 5,543,777 5,400,014 5,552,763 4,796,025 DES 377,460 Contact your local Simplex product supplier for information on additional TrueAlarm 4 02 Locations locations should be determined only after careful of the physical layout and contents of the to be protected Refer to NFPA 72 the National Fire Code On smooth ceilings spacing of 30 ft 9.1 m be used as a guide detailed installation information refer to 4098 Sensors and Bases Application Manual part number 574 709 QuickConnect2 Sensor Product Selection and Base QuickConnect2 TrueAlarm Sensor 4098 9788 base ordered separately Mounting base for 4098 9757 one for each 4098 9757 sensor ordered separately for mounting to surface mounted boxes and 4 square flush boxes be used when retrofitting to existing bases Plate Plate Specifications and Communications Allocation Channel Capability Connections on 4098 9788 Base Velocity Range Listed Temperature Range Temperature Range Range by IDNet Communications 24 40 VDC with data 410 typical address per sensor to 250 sensors devices per 4010 Fire Alarm Control Panel terminals for in out wiring and shield continuity connection to 14 AWG 0.82 to 2.08 mm2 selectable as 2.5 3.0 or 3.7 ft obscuration ft min 0 610 m min to 100 F 0 to 38 C to 122 F 0 to 50 C to 95 RH from 32 to 122 F 0 to 50 C non condensing White to mounting illustrations on page 3 4 02 Mounting Information Box Requirements octagonal or 4 square 1 1 2 deep gang 2 deep mount reference 102 mm box 102 mm box 38 mm box depth mount reference mount even with final or with up to 1 4 6.4 mm maximum recess mm Adapter Plate required for mounting surface mounted boxes and to 4 square flush mount boxes 162 mm to address on back Base QuickConnect2 sensor status indicator red lens Dimension Reference 124 mm mm height 17 mm 4 02 Simplex the Simplex logo TrueAlarm and IDNet are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association NFPA Massachusetts 01441 0001 USA www simplexnet com 2002 Simplex Time Recorder Co DBA TEPG US a Tyco company All rights reserved specifications and other information shown were current as of document revision date and are subject to change without notice 4 02