Simplex 4098-XAD-100, 4098-XAD-110, 4098-XAD-200, 4098-XAD-210 TrueAlarm® Analog Sensing – Air Aspiration Addressable Duct Smoke Detection with TrueAlarm Photoelectric Sensor(s)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
ULC Listed CSFM Approved Analog Sensing Air Aspiration Addressable Duct Smoke Detection TrueAlarm Photoelectric Sensor s Supports remote housing up to 50 ft 15 m with 3 4 Single Inlet Duct Sensor Housing Duct Kit not shown Features aspiration duct smoke detection system remote sensor location for ducts with service access Available as either a single or dual inlet detection includes a TrueAlarm photoelectric sensor addressable base per inlet For use with Simplex addressable fire alarm control supporting IDNet or MAPNET II Supports remote housing up to 82 ft 25 m with 1.05 mm O D rigid pipe mm O D flexible tubing controlled aspiration system Adjustable air speed settings for easy setup Monitors airflow from the HVAC ducts indicators located under the front cover for programming and status indications Easily accessible air filter element 4098 XAD 110 Single inlet housing with one smoke sensor Dual inlet housing with two smoke sensors one per duct probe kit 4098 XAD 210 duct probe kit For ducts wider than 90 features UL listed to Standards 268 and 268A ULC listed to Standard S529 Requires separate 24 VDC power Duct sensor housing with supervised output for remote relays Relay output is controlled through programming at the alarm control panel and can be activated manually or in response to a separate or other input or can be bypassed for system testing functions on interface board accessed removing the cover Remote functional smoke testing capability Magnetic test feature for alarm initiation at housing tubes ordered separately Available in multiple lengths to match duct size Dual Inlet Duct Sensor Housing Duct Kit not shown module options ordered separately Remote red status alarm LED 2098 9808 Remote test station with LED 2098 9806 4098 9843 remote relays Please note that smoke detection in air ducts is intended to provide of the presence of smoke in the duct Smoke detection in ducts is not intended to and will not replace smoke detection for open areas or other non duct applications These products have been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation listings may be applicable contact your local Simplex product supplier for the status 4 2011 located smoke sensors For smoke in HVAC ducts or other area locations that are and or difficult to access these smoke systems mount the sensor remotely and sample air using traditional air aspiration techniques Smoke Sensing Mounted in the smoke housings is a Simplex TrueAlarm photoelectric sensor that samples the air and reports its analog information to the fire alarm control panel for This provides the TrueAlarm smoke sensing set complete with environmental compensation Dirty Excessively Dirty and Almost Dirty detection Operation Aspiration Air is actively drawn from the ducts sampling holes in duct mounted sampling tubes air is then filtered before being analyzed by the sensor Models are available as either a or dual sensor version Supervision Airflow is provided by a high aspirator with programmable flow and circuitry Airflow is displayed on a ten bar graph located under the front cover that can adjusted for high and low flow thresholds Flow failure reported as a trouble to the fire alarm control panel for humid environments An optional trap with a ball valve can be ordered The water condensation that accumulates in a clear water trap be easily seen and can be drained utilizing a ball well before nuisance alarms or troubles develop due moisture configuration programming Function buttons to setup the Simplex are located on the housing The XAD requires settings the aspirator speed and air flow are configured during commissioning phase the use of special tools Unlike other aspirating no special engineering software is required to the Simplex XAD detection system air filter element The Simplex XAD a replaceable air inlet filter The filter element eventually become contaminated with dust particles airflow and it is recommended that the filter is changed every 12 months or as necessary The of filter replacement depends on environmental Test Capability The XAD can be functionally at the remote location where it is mounted A test port is located in the inlet tubes so that a test that requires smoke or simulated smoke to the detection chamber can be initiated TrueAlarm Sensor Operation Communication of Analog Sensing information from the sensor is digitally to the control panel where it is analyzed input is stored and tracked as an average value an alarm or abnormal condition being determined by the sensor present value against its average Data Evaluation Monitoring each sensor average value provides a software process that compensates for environmental dust dirt etc and component aging providing accurate reference for evaluating new activity The is a significant reduction in the probability of false nuisance alarms caused by shifts in sensitivity either or down Panel Selection Peak activity per sensor is to assist in evaluating specific locations The alarm point for each sensor is determined at the control selectable as the individual application requires Status LED Each sensor red status LED on the electrical interface board accessed by the cover pulses to indicate communications the panel If the control panel determines that a is in alarm or that it is dirty or has some other type trouble the details are annunciated at the control panel that sensor housing status LED will be turned on During a system alarm the control panel will the LEDs such that an LED indicating a trouble return to pulsing to help identify any alarmed sensors Status Alarm LEDs shown below track the of the duct sensor housing LED Status Alarm Indicator and Test Station Fire Alarm Control Panel Features smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 and S537 sensitivity testing Peak value logging allows accurate analysis for selection Automatic once per minute individual sensor check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor in easy to understand terms 4098 9843 Remote relay is under panel control for OFF or override 4 2011 Product Selection Inlet Duct Detection Application inlet sensor housing with single duct probe kit LF42241 refer to diagram on page 4 for equipment Tubes to table below ft 7.5 m Flexible dual core tubing ft 15m Flexible dual core tubing inlet water trap kit Optional recommended for humid environments Tubes Selection Chart Ordered Separately Per Duct Width Select One Overall Duct Width Up to Kit Required 686 mm 1372 mm 2286 mm one 18 457 mm Inlet Sampling Tube 2 and one 8 203 mm Exhaust Tube 2 Holes one 36 914 mm Inlet Sampling Tube 3 and one 8 203 mm Exhaust Tube 3 Holes one 60 1524 mm Inlet Sampling Tube 4 and one 8 203 mm Exhaust Tube 4 Holes inlet sensor housing with dual duct probe kit LF42243 refer to diagram on page 5 for equipment Select one either 25 ft or 50 ft length