Simplex TrueAlarm Smoke Detectors, Duct Detector Housing with Photoelectric Detector for 2-Wire or 4-Wire Operation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealarm-smoke-detectors-duct-detector-housing-with-photoelectric-detector-for-2-wire-or-4-wire-operation-9320175864.pdf |
---|---|
Type | |
Size | 683.49 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Smoke Detectors Duct Detector Housings with TrueAlarm Photoelectric for 2 Wire or 4 Wire Operation device is a duct smoke housing When provided with detector it is designed to sample the air flow by it in the air duct to determine whether it contains unacceptable levels of smoke The of a duct smoke detector is highly dependent upon the design and operating conditions of the handling system in which it is installed variables such as smoke dilution and stratification over which the best designed systems have no control and proper placement and positioning of the duct smoke which is often compromised for practical reasons For the reasons stated above the effectiveness this duct smoke detector cannot be warranted or guaranteed Under no circumstances should this duct detector be used or regarded to be a substitute for the building Fire alarm and detection system to this device is attached as a secondary detection device NOT REMOVE THIS NOTICE air duct detector housing with clear to monitor for the presence of smoke factory installed TrueAlarm smoke detector and features On board TrueAlarm sensitivity drift compensation dirt accumulation tracking Multi function status LED indicator Magnetic test that initiates an alarm and provides diagnostic information Clear cover allowing visual inspection Test ports provide functional smoke testing access cover in place UL listed to Standard 268A availability 4098 9685 2 Wire standard operation 4098 9688 2 Wire with supervised control for a remote relay relay included 4098 9686 4 Wire operation with supervised control multiple remote relays includes one remote relay to rectangular ducts or round ducts Minimum size is 8 203 mm square or 18 mm diameter operated functional test alarm and displays dirt accumulation status the detector status LED Assists with maintenance priorities by categorizing status and identifying dirty detectors and serviced with housing in place tubes ordered separately Available in multiple lengths to match duct size module options ordered separately Red alarm LED 4098 9830 Test stations with LED s and keyswitch refer to page for compatibility Relays for remote control applications These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products Please note that smoke detection in air ducts is intended to provide of the presence of smoke in the duct It is not intended and will not replace smoke detection requirements for open or other non duct applications Detector Housing Front and Bottom View Alarm Indicators and Test Stations Operation Simplex air duct smoke detector housings a TrueAlarm smoke detector for monitoring air or ventilating ducts Sampling tubes are into the duct allowing air to be directed to the detector mounted in the housing These duct detector with smoke detectors are compatible with Simplex alarm control panels that provide conventional two wire four wire initiating device circuits IDCs Details supports a remote red alarm LED or a remote test with LED s Models with relay output provide relay wiring supervision that will transfer a trouble to the IDC supervision is lost Model 4098 9685 provides basic smoke detection applications that do not require a remote relay Power is the IDC Model 4098 9688 provides a supervised relay for connection to a single 4098 9841 relay This is powered from the IDC and requires connection as only device to ensure relay operation Model 4098 9686 provides a supervised relay output that can control up to 15 4098 9843 control Relay supervision troubles are indicated by a yellow on the interface board Resettable 24 VDC is required page 4 Remote test station 4098 9835 is available for with this model to provide a test keyswitch a red LED indicator and a green power on LED 11 2014 Indicator and Remote Test Stations Select one if required assembly is on a single gang stainless steel plate wiring is 18 AWG 0.82 mm2 color coded wire leads Duct Detector Selection Chart Smoke Detector Housing with Photoelectric Detector Duct Detector standard operation Duct Detector with supervised single remote relay output one 4098 9841 relay NOTE Must be only device on for proper relay operation When used with the Simplex or 4005 fire alarm control panel connect to current only Duct Detector with supervised multiple remote relay output resettable 24 VDC fire alarm power and relay end of line 4081 9008 includes one 4098 9843 relay LED alarm indicator Station with keyswitch and red LED alarm indicator switch to initiates alarm for system testing Station with keyswitch red LED alarm indicator and green LED Encapsulated Remote Relays and End of Line Resistor is 18 AWG 0.82 mm2 color coded wire leads dual Form C 1 2 A 120 VAC with 4098 9688 single Form C 7 A 120 VAC one with 4098 9686 Resistor Harness 10 k 1 2 W ref 733 894 to supervise remote relay coil connection to pages 3 4 for relay relay s relay is required proper operation to 15 total 4098 9843 additional relays are separately LED and stations below only single gang box H x 2 W x 2 D mm x 51 mm 51 mm only maximum only up to 15 relays within ft 1 m of device controlled per 72 last relay location Each duct housing includes an internally mounted model 4098 9601 TrueAlarm photoelectric detector and an exhaust tube A correctly sampling tube ordered per application is required refer to chart below Sampling Tube Selection Chart Ordered Separately Per Duct Width Select One Duct Width Required Cut Length 305 mm to 23 330 mm to 584 mm to 46 610 mm to 1168 mm to 71 1168 mm to 1803 mm to 95 1803 mm to 2413 mm 12.7 mm longer than duct width 12.7 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width TrueAlarm Detector Status LED Indications approximately every 4 seconds Indication On LED Response to Magnetic Test By Indication turns ON is initiated pulses quickly times in 3 seconds turns ON pulses slowly times in 8 seconds turns ON is initiated is initiated not initiate Alarm sensitivity is within range sensitive out of normal range sensitive out of normal range is malfunctioning or other is required is required Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from red LED status indicator on the detector Refer to Installation Instructions 574 776 for further test and maintenance information 11 2014 Duct Detector Housing Det