System Sensor 2100TR Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-2100tr-manual-6720519483.pdf
Type PDF
Size 673.67 KB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Photoelectronic Smoke with Fixed Heat 1 Wiring diagram for the 2100TR detector 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 OBSERVE POLARITY must be observed on the remote annunciator connections LISTED CLASS A WIRING ONLY ONE DETECTOR PER ZONE CAN BE USED inches 140 mm inches 43 mm oz 190 g to 100 F 0 to 38 C to 93 Relative Humidity Noncondensing by momentary power interruption F Fixed Temperature Electronic Thermistor or 24 VDC VDC VDC of nom Voltage peak to peak average 100 maximum mA minimum 100 mA maximum current must be limited to 100mA by the control panel If used the RA400Z Annunciator operates within the specified detector alarm currents VDC minimum seconds maximum seconds maximum after 60 sec reset 12 24 VDC mA maximum 30 VAC 30 VDC one detector can be used per zone including mounting bracket Temperature Range Humidity Range Alarm Sensor Ratings Voltage nominal Ripple Voltage Current Ratings Voltage Time Time Relay Annunciator Output Relay Contact Ratings Load Considerations 2 Surface mounting of 2100TR smoke detec on 31 2 inch and 4 inch octagonal box detectors also include an output that allows optional of the RA400Z Remote Annunciator Installing thoroughly read the System Sensor manual I56 407 for Proper Use of System Smoke Detectors which pro detailed information on detector spacing placement wiring and special applications Copies of this are available at no charge from System Sensor This manual shall be left with the owner user of equipment This detector must be tested and maintained NFPA 72 requirements The detector should be at least once a year Description 2100TR is a 2 wire photoelectronic smoke detector uses a state of the art optical sensing chamber This also provides restorable 135 fixed temperature detection The 2100TR heat detection unit is integrated the photoelectronic sensor This detector is designed provide open area protection and to be used with com UL listed panels only of this detector is simplified by the use of a bracket and a plug in screw terminal block that can prewired to the system allowing the detector to be easily or removed for cleaning The detector sensitivity be tested in place using the MOD400R Test Module LED on the detector provides a local visual indication of detector status If power is applied to the detector and is functioning normally in standby within the listed sensi range the status LED blinks every ten seconds The also latches on in alarm If the LED stops blinking the should be removed for maintenance and inspection 3 2100TR smoke detector mounting bracket 2100TR detector is supplied with a mounting bracket permits the detector to be mounted To a single gang box or Directly to a 3 1 2 inch or 4 inch octagonal box or To a 4 inch square electrical box by using a plaster ring Directly to the ceiling using drywall anchors if permit by local codes and or the authority having jurisdic Feature detector includes a tamper resistant feature that pre its removal from the bracket without the use of a To make the detector tamper resistant remove the tab by breaking it at the scribed line on the tamper tab on the detector mounting bracket see Figure then install the detector To remove the detector from bracket once it has been made tamper resistant use a screwdriver to depress the tamper resistant tab lo in the slot on the mounting bracket and turn the de counterclockwise Installation Guidelines wiring must be installed in compliance with the Na Electrical Code applicable local codes and any spe requirements of the local authority having jurisdiction wire gauges should be used The conductors used to smoke detectors to control panels and accessory should be color coded to reduce the likelihood of errors Improper connections can prevent a system responding properly in the event of a fire screw terminal block accepts 14 22 gauge wire For system performance all wiring should be installed in grounded conduit Do not mix fire system wiring the same conduit as any other electrical wiring Twisted may be used to provide additional protection against interference detectors and alarm system control panels have for allowable loop resistance Consult the SLOT TAB TO DETECTOR RESISTANT TAB CUT OFF SMALL TAB TO ACTIVATE TAMPER RESIST FEATURE panel specifications for the total loop resistance al for the control panel being used before wiring the loops Sensor smoke detectors are marked with a compat identifier located as the last digit of a five digit code on the back of the product Connect detectors only compatible control units as indicated in System Sensor chart which contains a current list of UL compatible control units and detectors A copy of this is available from System Sensor upon request connections are made by stripping about 1 4 inch of from the end of the feed wire inserting the wire the appropriate terminal and tightening the screw to the wire in place power from the control unit or initiating device cir before installing detectors Wire the plug in screw terminal block per Figure 1 and the terminal block into the detector Align the arrows on the detector with the arrows on the Turn the detector clockwise in the mounting bracket un bracket it clicks into place After all detectors have been installed apply power to control unit or initiating device circuits Test the detector as described in TESTING Reset the detector at the system control panel Notify the proper authorities the system is in operation

Related Files