System Sensor 6500-MMK 6500-SMK Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-6500-mmk-6500-smk-manual-2184970536.pdf |
---|---|
Type | |
Size | 835.10 KB |
Downloads |
Text Preview
6500 MMK SMK KIT FOR USE WITH THE RANGE OF BEAM SMOKE DETECTORS instructions have been approved by UL multi mount kit allows any of the 6500 range of beam detectors to be mounted to a wall or the ceiling It is designed to create an additional alignment range in where the detector and reflector cannot be mounted within 10 alignment of each The kit includes the hardware necessary to mount either a single transmitter unit or a single reflector To mount the transmitter receiver the surface mount 6500 SMK is also required If both the transmitter receiver and the reflector require alignment range two kits will be needed The kit is not compatible with the reflector kit kit comes partly pre assembled into the following components the parts can be by matching the reference numbers to the numbers in Figs 1 3 fixed bracket x 15mm hex allen head bolts split lock washers x 16mm pan head screws hex nuts washers split lock washers Num THE BRACKETS installing to a wall or ceiling use an appropriate anchor method to ensure the weight of the assembly can be securely supported Install the fixed bracket to a or ceiling so that when mounted the transmitter receiver and the reflector will have clear line of sight between them Mount the bracket only on solid structures of the To avoid unwanted alarms due to wall movement do not mount to flexible walls as sheet metal walls see the Detector Mounting section of the beam detector for more details the T Bracket to the fixed bracket using the allen head bolts as shown in Fig 1 forget to use the split lock washers too Do not fully tighten the bolts until and testing are complete AND WIRING INSTRUCTIONS TRANSMITTER RECEIVER surface mount kit 6500 SMK must be used with the transmitter receiver to provide entry Read the installation instructions of the beam detector to determine the appropriate of wires to be used Drill the appropriate holes for the conduit using the drill centres provided on all four of the surface mount box see Fig SMK1 A Conduit sizes of up to 20mm are Mount the surface mount box on to the T bracket of the multi mount kit using the pre holes see Fig SMK1 B and Fig 2 and the M4 screws and washers proper operation of the beam detector the surface mount box must be Securely mounted to ensure no subsequent movement of the beam detector will after the installation is completed Mounted to ensure there is line of sight between the transmitter receiver unit the reflector See the beam detector manual for further details Attach the transmitter receiver unit with cover and faceplate removed securely to surface mount box using the four supplied screws Pull wiring and conduit through the drilled hole s Secure conduit fitting as required supplied Be sure to leave enough wire to reach the connectors Complete the installation and testing of the transmitter receiver unit using the included with the beam detector Only when installation is complete tighten the bolts connecting the T bracket to the fixed bracket NOTE Ensure bolts are fully tightened to maintain mounting integrity INSTRUCTIONS REFLECTOR Mount the reflector on to the T bracket of the multi mount kit using the three M4 see Fig 3 proper operation of the beam detector the reflector must be Securely mounted to ensure no subsequent movement of the reflector will after the installation is completed Mounted to ensure there is line of sight between the transmitter receiver unit the reflector See the beam detector manual for further details Mounted so that the reflector is perpendicular to the line of sight of the unit Complete the installation and testing of the beam detector as per its manual Only installation is complete fully tighten the bolts connecting the T bracket to the bracket see Fig 3 If not installed correctly the BEAM detector may not function properly The 6500 MMK is also compatible with the following models BEAM200S BEAM1224 BEAM1224s FSB 200 BEAM355 BEAM355S 1 2 3 SMK1 Tecnologica S r l Via Caboto 19 3 34147 Trieste ITALY System Sensor 2007 I56 2625 005 MULTI MOUNTING PER LA GAMMA 6500 DI DI FUMO A FASCIO kit multi mount consente l di qualsiasi dispositivo della gamma 6500 rilevatori a fascio sia a parete che a soffitto La sua funzione fornire una di allineamento supplementare nei casi in cui risulti impossibile montare il e il riflettore a 10 l dall Il kit contiene la strumentazione necessaria il montaggio di un unit trasmittente ricevente o di un unico riflettore Per montaggio dell trasmittente ricevente necessario anche il kit di montaggio superficie 6500 SMK Nel caso in cui sia l trasmittente ricevente che il necessitino di una soluzione di allineamento supplementare saranno due diversi kit Il presente kit non compatibile con il kit per riflettore a raggio kit viene fornito parzialmente preassemblato con i seguenti componenti i componenti essere identificati abbinando i numeri di riferimento con i numeri riportati figure 1 3 rif fissa per montaggio a parete a soffitto 1 a T Allen a testa esagonale M6 x 15 mm 3 M6 a testa troncoconica M4 x 16 mm esagonali M4 M4 M4 DELLE STAFFE momento dell a parete o a soffitto importante utilizzare un metodo ancoraggio appropriato che garantisca il supporto in sicurezza di tutto il peso Installare la staffa fissa ad una parete o al soffitto in modo che montati tra l trasmittente ricevente e il riflettore vi sia una chiara Montare la staffa solo a strutture fisse dell Onde evitare l allarmi indesiderati dovuti a movimenti della parete non montare la staffa a pareti quali pareti in lamine di metallo per maggiori dettagli ved la sezione del rilevatore del manuale relativo al rilevatore a fascio la staffa a T alla staffa fissa utilizzando i bulloni Allen a testa esagonale mostrato nella Fig 1 non dimenticare di utilizzare anche le rondelle Non serrare a fondo i bulloni prima di aver completato l e la DI MONTAGGIO E CABLAGGIO UNIT TRASMITTENTE RICEVENTE un corretto cablaggio dell trasmittente ricevente utilizzare il kit di montaggio superficie 6500 SMK Leggere le istruzioni di installazione del rilevatore a fascio per stabilire il numero di cavi da utilizzare Eseguire i fori indicati per il tubo utilizzando i centri di foratura presenti su tutti e i lati della scatola per montaggio a superficie ved Fig SMK1 A Sono idonei tubi con dimensioni fino a 20 mm Montare la scatola per montaggio a parete sulla staffa a T del kit multi mount i fori prefilettati ved Fig SMK1 B e Fig 2 le viti e le rondelle M4 un corretto funzionamento del rilevatore a fascio la scatola per montaggio a deve essere Saldamente fissata in modo che al termine dell non si verifichi movimento del rilevatore a fascio Montato in modo tale che tra l trasmittente ricevente e il riflettore vi una chiara visibilit Per ulteriori dettagli ved il manuale del rilevatore fascio Fissare saldamente l trasmittente ricevente senza coperchio e protezione alla scatola per montaggio a superficie utilizzando le quattro viti in Inserire i cavi e il tubo attraverso i fori praticati Fissare i raccordi del tubo come non in dotazione Accertarsi che vi sia cavo a sufficienza per raggiungere connettori Completare l e la verifica dell trasmittente ricevente seguendo istruzioni allegate al rilevatore a fascio Solo al termine dell serrare fondo i bulloni che collegano la staffa a T alla staffa fissa NOTA Accertarsi per garantire l del montaggio tutti i bulloni siano stati serrati a fondo PER IL MONTAGGIO RIFLETTORE Montare il riflettore sulla staffa a