System Sensor BEAM200 and BEAM200S Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-beam200-and-beam200s-data-sheet-2940581763.pdf
Type PDF
Size 856.83 KB
Downloads

Text Preview

BEAM200 S Type Beam Detectors BEAM200 and BEAM200S single ended reflected beam detectors are uniquely suited for protecting open areas high ceilings where other methods of smoke detection are to install and maintain 16 to 328 foot protection range Single ended reflective design Easiest alignment in the industry with digital display 6 field selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug in terminal blocks Built in automatic gain control compensates for signal from dust build up Remote test station available Paintable cover Optional heater kits available Listings System Sensor BEAM200 and BEAM200S intelligent beam smoke detectors are designed to be used with Listed compatible control panels only Since all of the wiring is to one side the installation of the single ended reflective is much easier than dual ended projected beam detectors is accomplished quickly via an optical sight and a 2 signal strength meter incorporated into the product Listed for from to 131 the BEAM200 detector can be used open area applications to provide early warning in environments temperature extremes exceed the capability of other types of detection BEAM200 smoke detector includes one wired transmitter unit and one reflector When smoke enters the area between unit and the reflector it causes a reduction in the signal The is activated when the smoke level reaches the predetermined BEAM200 device has four standard sensitivity selections along two Acclimate settings When either of the two Acclimate are selected the detector automatically adjusts its sensitivity advanced software algorithms to select the optimum sensitivity the specific environment BEAM200S model is equipped with an added feature an sensitivity test feature that uses a test filter attached to a motor inside the detector optics Using the remote test station the motor is activated and moves the filter in the of the light beam thereby testing detector sensitivity This sensitivity test feature allows the user to quickly and easily the annual maintenance and test requirements of NFPA 72 and BEAM200S Specifications Specifications Range Angle Levels Specifications BEAMHKR Consumption Parts to 32 V mA Max at 32 V per reflector W at 24 V 15 W at 32 V per reflector Condition Trouble Aid Indicator Indicator Indicator Features Detector Spacing ft to 328 ft 5 m to 100 m Degrees horizontal vertical optics move independent of the unit 1 25 2 30 3 40 4 50 Level 1 30 to 50 Level 2 40 to 50 or more obscuration blockage alignment mode initial alignment limit reached gunsight signal strength indication digit display red LED and remote alarm yellow LED and remote trouble flashing green LED Sensitivity Test Filter BEAM200S only additional external power supply filter Incremental scale on reflector test switch reset switch test and reset switch Compatible with RTS151 and RTS451KEY RTS151 test smooth ceilings 30 to 60 feet between beams and not more than one half spacing between a projected beam and a Other spacing may be used depending ceiling height airflow characteristics and requirements See NFPA 72 to 131 to 55 to 93 RH Noncondensing GUNSIGHT SIGNAL METER OPTICS KNOB OPTICS KNOB Only used for BEAM200S See electrical ratings PANEL OR DEVICE LINE VDC MAX PAIR IS NEXT Test Feature only MOTOR FILTER Specifications Specifications Standby Current 24VDC Current During Testing Current 24VDC Current 24VDC Mode Current 24VDC Specifications Dimensions Dimensions 16 to 230 Dimensions 230 Specifications BEAMHK Consumption Information No beam smoke detector with 8 reflector beam smoke detector with 8 reflector and sensitivity test to 32 VDC mA Max mA Max mA Max mA Max mA Max in H 7.5 in W 3.3 in D mm H 191 mm W 84 mm D in 9.1 in 200 mm 230 mm in 18.1 in 400 mm 460 mm to 32 V mA at 32 V W at 24 V 3 W at 32 V RTS151 range accessory kit 3 additional reflectors for applications in excess of 230 ft 70 m kit Provides ceiling or wall mount capability increased angular adjustment for either the beam the reflector When installed with the transmitter unit BEAMSMK must be used as well mount kit for use with BEAMMMK duty multi mount kit for installations prone to or where there is difficulty in maintaining the angle When installed with the transmitter receiver 6500 SMK must be used as well mount kit for use with the 6500 MMK kit for transmitter receiver unit See electrical above kit for reflector See electrical requirements test station with key lock test station used to initiate the NFPA sensitivity function Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 07 09

Related Files