System Sensor CO1224T CO1224TR

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-co1224t-co1224tr-8361947250.pdf
Type PDF
Size 1.34 MB
Downloads

Text Preview

CO1224A dangerous amounts of CO are detected the CO1224 CO detectors alert residents by sounding and ashing a temp signal alarm With 24 7 central station monitoring residents are protection whether they are away from home sleeping already suffering from the effects of CO CO1224 Series detectors are designed for system operation detectors are fully listed to UL 2075 US models only and 6.19 01 Canada model only and offer a code required trouble to send a sensor failure or end of life signal to the control and the central station The CO1224 Series detectors also SEMS type terminal Philips head screws for quicker and more wiring connections and code required wiring supervision a low current draw these detectors enable more devices to be to the panel limiting the need to purchase extra power or more expensive panels As 12 24 VDC detectors the Series detectors will operate on most industry security and re alarm control panels RealTest technology the CO gas sensing cell used in the Series CO detectors can be tested using a CO gas agent meeting the requirements of NFPA 720 2009 US models only put the detector into RealTest mode spray a small amount CO into the detector per the installation instructions and within the detector will alarm indicating successful gas entry See reverse page or the user manual for complete instructions Series Monoxide RealTest System Sensor CO1224T CO1224TR and CO1224A Carbon Monoxide CO Detectors use a highly and reliable electrochemical sensing cell to early warning of dangerous CO levels A 10 year end of life timer RealTest enables a functional test using canned CO A code required trouble relay Wiring supervision with SEMS terminals 12 24 VDC A low current draw of 20 mA in standby and 40 mA in alarm Versatile mounting for wall and ceiling Accurate and reliable electrochemical sensing technology Optional CO PLATE CO Detector Replacement Plate to upgrade installed competitor detectors to the CO1224T or CO1224T tested up to 12,000 feet above sea level Listings CO1224T are in full with UL and CO1224A is full compliance with CSA 6.19 01 Series Detectors Carbon Monoxide Detector Specifications Specifi cations monoxide CO detector shall be a system connected System Sensor model number CO1224T or CO1224TR listed to Underwriters UL 2075 for Gas and Vapor Detectors and Sensors The Canadian model CO1224A is ULC listed to CSA 6.19 01 for residential monoxide alarm devices The detector shall be equipped with a sounder and a trouble relay The detector base shall be able to to a single gang electrical box or direct surface mount to the wall or ceiling Wiring connections shall be made by means of SEMS The detector shall provide dual color LED indication that blinks to indicate normal standby alarm or end of life When the sensor is in a trouble condition the detector shall send a trouble signal to the panel When the detector gives a trouble or end of life the detector shall be replaced The detector shall provide a means to test CO gas entry into the CO sensing cell The detector shall this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry For the CO1224T only detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time speci ed by ANSI UL 2034 CO concentrations of 70 150 and 400 parts per million ppm as veri ed by a Nationally Recognized Test Laboratory Specifi cations Voltage Signal Current Current Contact Ratings Contact Ratings Specifi cations CO1224T CO1224A CO1224TR Weight Temperature Range Humidity Range Terminals Modes Mode standby 5.1 in 130 mm Width 3.3 in 84 mm Height 1.3 in 33 mm 6.0 in 152 mm Height 1.3 in 33 mm CO1224A 7 oz 198 g CO1224TR 11 oz 312 g to 104 F 0 to 40 C to 90 RH to 22 AWG back box surface mount to wall or ceiling VDC dB in alarm mA mA 75 mA test A 30 VDC A 30 VDC in temp 4 pattern LED in temp 4 pattern LED 1 per minute The System Sensor CO1224 Series CO Detectors enable evaluation of the functionality of the CO sensing cell using a canned CO test agent Feature Check with codes and the to determine a functional gas is desired for an and hold the Test Hush button for seconds to enter RealTest mode The LED will ash once every second to RealTest mode has started canned CO agent into the CO sensing at the control panel detector will automatically exit alarm mode after about 20 60 Feature Feature Timer Pushing the Test Hush button will silence the sounder for 5 minutes except in RealTest mode When the detector is in a trouble condition it will send a trouble signal to the panel After the detector internal sensor has reached the end of its life a trouble signal will be sent to the panel indicate it is time to replace the detector An electrochemical CO detector lifespan is about ten years detector must be replaced by the date marked on the inside of the product System Sensor also offers the CO PLATE CO Detector Replacement Plate to cover the footprint when necessary previously installed competitive carbon monoxide detectors that require replacement Information No volt 6 wire system monitored carbon monoxide detector with RealTest Technology US only volt 6 wire system monitored round carbon monoxide detector with RealTest Technology US only volt 6 wire system monitored carbon monoxide detector with RealTest Technology Canada only detector replacement plate to cover the footprint of previously installed competitive detectors US Canada 3825 Ohio Avenue Charles IL 60174 6581 Kitimat Rd Unit 6 Ontario L5N 3T5 System Sensor Product speci cations subject to without notice Visit our websites for current product including the latest version of this data sheet 10 16

Related Files