System Sensor FAAST XM 8100 Series Firmware Release Notes

File Preview
File Preview
Click below to download for free

Text Preview

o Changes are for internal use only during manufacture S04 0138 008 firmware revision 0.0 1.0 2.0 or 3.0 firmware revision 20.0 affected All firmware revision 0.0 1.0 2.0 or 3.0 firmware revision 19.0 S04 0138 007 affected All firmware update should only be applied to devices with Main Board Revision 10 or higher current firmware Main Board Revision can be found by connecting to a device using PipeIQ right clicking on the device and selecting Device Information confirm that Firmware Revision Main Board Revision is 10 or greater device bootloader is not upgraded with this firmware update Devices with the listed version can be updated with this firmware update but the bootloader version number remain the same Cyber Security Fixes User Interface Webserver All passwords are encrypted while communicating with PipeIQ and web server Press and hold the Reset button for 30 to 40 seconds to reset the IP settings to factory default Press and hold the Reset button for 40 to 50 seconds to reset the airflow baseline The airflow on the user interface will now indicate the amount of time remaining to re baseline the The webserver has been updated to better resemble the FAAST XS and XT webservers Added viewing for the following Sensor User interface and Modbus Configurations Trend and Messages Logs Device information Added support for Google Chrome Microsoft Internet Explorer and Mozilla Firefox browsers Added support for Safari browser Mac only Changed auto logoff time to 20 minutes Added multi language support for message logs and general configuration details Modbus Bootloader Modbus Identifier and Device Identification Number can now be unique Common Modbus map for all FAAST XS XM and XT devices NOTE After firmware upgrade the need to modify the existing faceplate of UI to properly display new Modbus map Connection timeout time changed to 20 minutes Configuration changes are now possible when a device is in CONFIGURATION or DISABLE mode CLIP devices now support smoke referencing via Modbus The IP address can be displayed when in bootloader mode Press and hold the Reset button for 30 to display the IP address Due to new firmware the firmware upgrade progress display on LEDs may not display correctly on with older bootloader versions Device Logs Trend logging frequency is now configurable from PipeIQ Total number of trend entries is now 4320 Circular buffer while logging trends into the device memory General changes A device will re calculate its baseline after every configuration download Added multilanguage support e mails Urgent and Minor faults are merged into a single Fault indication Firmware upgrade events are now logged The default configuration time stamp is 1 Jan 2015 user interface has been updated to indicate the amount of time remaining during airflow baselining the system has not been baselined or a baseline reset has been initiated the device will illuminate all 10 on the airflow graph As the baseline period progresses the segments will gradually turn off starting the outside until it reaches the two center segments indicating the device has completed baselining The period is approximately 5 minutes the device was previously baselined then the two center segments on the airflow graph will blink during the on initialization period The power on initialization period is approximately 5 minutes S04 0138 006 firmware revision 1 firmware revision 12.0 date September 2014 affected General changes Acclimate operation update Added ZIP formatted firmware upgrade file for use in PipeIQ 2 x and greater S04 0138 005 firmware revision 1 firmware revision 11.0 date May 2014 affected General changes Modbus TCP includes the use of the Device Indentifier Refer to System Sensor Modbus User Guide Schema S04 0138 004 firmware revision 1 firmware revision 10.0 date September 2013 affected General changes Airflow monitoring

Related Files