System Sensor i4 Series CO Smoke Detectors - Dealer

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-i4-series-co-smoke-detectors-dealer-7315946820.pdf
Type PDF
Size 737.04 KB
Downloads

Text Preview

What is the i4 Series combination CO smoke detector System Sensor i4 Series includes both a 12 24 volt system combination electrochemical carbon monoxide CO smoke detector and a module that interfaces with a Below are the model numbers else does the module do module allows interconnectivity of all devices on the loop maintenance signaling and EZ Walk loop testing capabilities devices only The RSS MOD is not needed for sounder Frequently Asked Questions Series Combination Detector No 12 24 volt system connected CO smoke detector with RealTest 12 24 volt system connected CO smoke detector with RealTest interface module required with COSMO models interface module required with COSMO models much money will I make save using the i4 Series two separate devices i4 Series can save you money in both labor and materials how depends on how many detectors you install and your current of materials You can determine your profit increase or cost by entering your information in our Value Calculator addition some homeowners have objected in the past to CO detection and monitoring due to the increased cost the system and the aesthetics of having multiple devices on the or ceiling The i4 Series overcomes these objections because it requires only one device on the wall or ceiling for both fire and protection and reduces the overall installed cost over a separate system the module necessary the module is the interface between the detector and the panel allows a 2 wire or 4 wire device to communicate distinct smoke and CO signals to the panel while reducing wiring as compared to separate smoke and CO devices many detectors can the module handle module can handle up to 12 detectors on a loop in any of i4 series and compatible i3 series smoke detectors sounders heat detectors be added to the loop and do they against the 12 detectors can only be used on the 4 wire i4 system and do not against the 12 detectors per module many zones does the system use 2 wire module uses two to three zones a smoke zone a CO zone an optional maintenance zone A 4 wire module uses two zones is the module compatible with module works with all i4 Series and compatible i3 Series smoke models 2WTA B 4WTA B allowing full interconnectivity and compatibility for retrofit applications which panels is the system compatible compatibility is not an issue because the module is a 4 wire The module can use a 2 wire smoke zone on a panel the way a 4 wire detector can use that zone Each module can 12 detectors and looks like a single 4 wire device to the the module is not powered by the 2 wire smoke zone many wires does the detector use COSMO 2W is a 2 wire device with 2 wires in and 2 wires out The is a 4 wire device with 4 wires in and 4 wires out many wires does the module have module uses 6 to 10 wires to connect to the panel two wires for two wires for the smoke zone two wires for the CO zone and optional two wires for the maintenance zone on 2 wire devices The trigger inputs are optional and are useful for interconnection multiple modules do I wire the detector or the module to the appropriate i4 Series installation manual or the wiring sheet does the module get its power module is like a 4 wire smoke detector it gets its power from the Smoke power or Auxiliary power output the power need to be resettable the power to the module needs to be resettable to reset the During a reset the detector will preserve its CO alarm state a smoke alarm reset the 3.9k end of line resistor be supplied it is included with the module is the CO trigger and what does it do CO trigger is optional it is useful for interconnection of multiple All panels can be programmed with auxiliary relays activate upon an alarm condition These provide a positive output that can be connected to the module CO trigger CO trigger input allows a single module to have CO silence capability and allows multiple module installations to have all activated in Temporal 4 in the event of a CO alarm using multiple modules will the sounders synch modules sounders will not be synchronized across modules If a bell output the panel is available it can be used to sound the modules trigger in unison are the trigger inputs one wire and not two are voltage referenced to the Aux In minus of the module modules be daisy chained together to save zones the panel each module must use its own fire and CO zones alarm only panels UL864 panels do not allow CO so how would you sync a CO alarm trigger cannot be used with UL864 panels Connection is not to cause the detectors to sound The use of the trigger is to multiple modules sound and to allow the keypad to be used to a CO alarm I have an installation with multiple zones how many are needed and can I still activate all device multiple zones are required then a module will be needed for each Maintenance zones can be combined at the panel and the can be wired to the trigger inputs on the module to activate the of all devices on the loop is the proper placement for the detector detector can be mounted on the ceiling or on a wall On the the detector should be at least 12 inches from any wall On wall the detector should be 4 inches down from the ceiling Do install outdoors or in any environment that does not comply the detector environmental specifications See the i4 Series manual or consult the applicable NFPA guidelines for instructions the detector be mounted on the ceiling it can be mounted on the ceiling at least 12 inches away from the please refer to the i4 Series installation manual and NFPA 720 Section 9.4.1.2 for more information is the detector mounted detector can be ceiling or wall mounted to a wide variety of boxes 3.5 and 4 Octagonal Single gang 2 x 4 3.5 4 round ceiling or directly mounted to the ceiling or wall using fasteners the RSS MOD needed to interconnect sounders the i4 module will activate the sounders of all detectors on the should the module be installed module can be mounted up to 20 feet away from the panel to 411 16 inch back box or in its own metal enclosure For UL864 the wiring should be enclosed within conduit or protected against mechanical injury is the module mounted module can be mounted to a 411 16 square back box or inside an If mounted inside an enclosure the module does not need plastic cover is the current draw of the detectors and modules the 2 Wire system the standby current is 45mA 12 volts in fully 27mA 24 volts in fully loaded For the 4 Wire system the current is 36mA 12 volts in plus 200uA per each i4 detector is the life of the CO cell life of the CO cell is 6 years It has a built in clock timer which when 6 years has passed the CO cell field replaceable the replacement part number is CO REPL and the part will be starting in 2017 type of canned CO should I use for the functional test Solo C6 canned CO is cross listed for use with the detector It is at most local security distributors agency listings does the detector have is UL 268 UL 2075 and CSFM listed can I get more training is a training module available at our i4 landing page There are also archived webinars available for at systemsensor com webinars is the price pricing information please contact your local security distributor can I purchase the i4 Series can be purchased at your local security distributor can I get more information the i4 Series landing page at systemsensor com i4 System Sensor C0FL29701 7 13

Related Files