System Sensor M500DM Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-m500dm-manual-8497130526.pdf
Type PDF
Size 1.31 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Dual Monitor Module Operating Voltage Current Draw Operating Current Resistance SLC wiring resistance IDC wiring resistance IDC Voltage IDC Current Range INSTALLING information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules to 32 VDC mA LED on LED flashing Ohms Ohms Ohms Volts to 120 0 to 49 to 93 Non condensing in H x 4.275 in W x 1.4 in D Mounts to a 4 inch square by 21 8 inch deep box Electrical Box directly to 4 inch square electrical boxes see Figure 2A The box have a minimum depth of 21 8 inches Surface mounted electrical boxes are available from System Sensor 2 MODULE MOUNTING 2B This manual should be left with the owner user of this equipment DESCRIPTION Dual Monitor Module is intended for use in intelligent two wire systems provides two independent 2 wire initiating device circuits IDC at two sep consecutive addresses It is capable of monitoring normally open con fire alarm and supervisory devices or either normally open or normally security devices REQUIREMENTS ensure proper operation these modules shall be connected to listed com system control panels only 1 CONTROLS AND INDICATORS All wiring must conform to applicable local codes ordinances and This module is intended for power limited wiring only Install module wiring in accordance with the job drawings and appropri wiring diagrams Set the address on the module per job drawings NOTE Monitor module L using terminals 6 and 7 responds at the ad set on the code switches Monitor module H using terminals 8 and will automatically respond at the next higher address For example if code switches are set to 76 module L will respond at address 76 and H will respond at address 77 Use caution to avoid duplicate ad of modules on the system Secure module to electrical box supplied by installer as shown in Fig 2 3 TYPICAL 2 WIRE INITIATING CIRCUIT CONFIGURATION NFPA STYLE B INITIATING DEVICE CIRCUITS L H EACH LIMITED TO 240 11 VDC MAX NEXT PANEL OR DEVICE 47k EOL 47k EOL MODULES TO LISTED CONTROL PANELS ONLY LINE CIRCUIT SLC VDC MAX PAIR IS RECOMMENDED LISTED CONTACT CLOSURE DEVICES MAY USED DO NOT MIX FIRE ALARM INITIATING OR SECURITY DEVICES ON THE INITIATING DEVICE CIRCUIT CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS WIRING SHOWN IS AND POWER LIMITED L TERMINALS 6 7 RESPONDS AT ADDRESS ON CODE SWITCHES MONITOR H TERMINALS 8 RESPONDS AT NEXT HIGHER ADDRESS LIMITED WARRANTY Sensor warrants its enclosed product to be free from defects in materials and under normal use and service for a period of three years from date of System Sensor makes no other express warranty for the enclosed product agent representative dealer or employee of the Company has the authority to in or alter the obligations or limitations of this Warranty The Company obligation this Warranty shall be limited to the replacement of any part of the product which is to be defective in materials or workmanship under normal use and service during three year period commencing with the date of manufacture After phoning System toll free number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso 79936 USA Please include a note describing the malfunction and suspected cause failure The Company shall not be obligated to replace units which are found to be because of damage unreasonable use modifications or alterations occurring the date of manufacture In no case shall the Company be liable for any consequen or incidental damages for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or consequential dam so the above limitation or exclusion may not apply to you This Warranty gives you legal rights and you may also have other rights which vary from state to state equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable against harmful interference This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications Operation is subject to the following two conditions 1 This device may not cause harmful radiation and 2 this must accept any interference received including interference that may cause undesired operation System Sensor 03 11 STATEMENT

Related Files