System Sensor M500FP Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-m500fp-manual-5472086913.pdf
Type PDF
Size 1.42 MB
Downloads

Text Preview

I 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 AND MAINTENANCE INSTRUCTIONS Firephone Control Module Operating Voltage Current Draw Operating Current Wiring Resistance Wiring Resistance Offhook Resistance Supply Voltage between Terminals T10 and T11 24VDC to 120 0 to 49 Range to 93 Non condensing H x 4.275 W x 1.4 Mounts to a 4 square by 21 8 deep box Electrical Box CB500 Barrier to 32 VDC LED on LED flashing Ohms Ohms to 1,500 Ohms 1 CONTROLS AND INDICATORS INSTALLING information is included as a quick reference installation guide If the will be installed in an existing operational system inform the op and local authority that the system will be temporarily out of service power to the control panel before installing the modules This manual should be left with the owner user of this equipment DESCRIPTION Firephone Control Modules are intended for use in intelligent two systems where the individual address of each module is selected using built in rotary switches This module is used to connect a remote fire telephone to a centralized telephone console A ringing sound is pro at each off hook handset until it is connected to the console Wiring to telephone jacks and handsets is supervised and status is reported the panel as NORMAL TROUBLE or TELEPHONE The M500FP has two of output termination points available for fault tolerant wiring and in a panel controlled LED indicator REQUIREMENTS ensure proper operation this module shall be connected to Listed compat system control panels only module mounts directly to 4 square electrical boxes see Figure 2A box must have a minimum depth of 21 8 Flush mounted electrical boxes are available All wiring must conform to applicable local codes ordinances and Install module wiring in accordance with the job drawings and appropri wiring diagrams Figures 3 4 the address on the module per job drawings Secure module to electrical box supplied by installer as shown in 2 2 MODULE MOUNTING 3 TYPICAL CIRCUIT CONFIGURATION NFPA STYLE Y CLASS B STYLE WIRING MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY NEXT LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED AND POWER LIMITED PANEL OR DEVICE CIRCUITS NOT LOOP WIRE AROUND TERMINALS ALL WIRE TO ENSURE OF CONNECTIONS POLARITIES ARE IN ALARM CONSOLE VOLTS DC POWER LIMITED Relay Contact Rating VDC 3 Amperes Maximum CONSOLE MUST ITS OWN SUPERVISION EOL NEXT EOL POLARITIES ARE IN ALARM 4 TYPICAL FAULT TOLERANT CIRCUIT CONFIGURATION NFPA STYLE Z CLASS A STYLE WIRING CONSOLE MUST ITS OWN SUPERVISION CONSOLE VOLTS DC POWER LIMITED Relay Contact Rating VDC 3 Amperes Maximum WIRING SHOWN IS SUPERVISED POWER LIMITED LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED MODULES TO LISTED COMPATIBLE PANELS ONLY PANEL OR DEVICE CIRCUITS NOT LOOP WIRE AROUND TERMINALS ALL WIRE TO ENSURE OF CONNECTIONS LIMITED WARRANTY Sensor warrants its enclosed product to be free from defects in materials and under normal use and service for a period of three years from date of System Sensor makes no other express warranty for the enclosed product agent representative dealer or employee of the Company has the authority to in or alter the obligations or limitations of this Warranty The Company obligation this Warranty shall be limited to the replacement of any part of the product which is to be defective in materials or workmanship under normal use and service during three year period commencing with the date of manufacture After phoning System toll free number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso 79936 USA Please include a note describing the malfunction and suspected cause of The Company shall not be obligated to replace units which are found to be defec because of damage unreasonable use modifications or alterations occurring after date of manufacture In no case shall the Company be liable for any consequential incidental damages for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or consequential dam so the above limitation or exclusion may not apply to you This Warranty gives you legal rights and you may also have other rights which vary from state to state relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module equipment has been tested and found to comply with the limits for a Class B digi device pursuant to Part 15 of the FCC rules These limits are designed to provide protection against harmful interference This equipment generates uses and radiate radio frequency energy and if not installed and used in accordance with the manual may cause harmful interference to radio communications Operation subject to the following two conditions 1 This device may not cause harmful radia and 2 this device must accept any interference received including interference may cause undesired operation System Sensor 03 11 STATEMENT

Related Files