System Sensor PDRP-1001

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-pdrp-1001-0482153679.pdf
Type PDF
Size 807.58 KB
Downloads

Text Preview

S P R I N K L E R S Y S T E M S M O N I T O R I N G Series Panel Available Pre Action Deluge Panel International 230V Panel Canadian Accessories Available Zone Relay Module Transmitter Module LED Interface Module Volt Amp Meter Supervised Remote Annunciator LED interface module 4XLM 911A Digital Communicator Overview initiating device circuits Style B D notification appliance circuits Y Z release circuits Style Y input Style B D hazard option or split release input option Style B D audible indications for 1 zone alarm 2 zones in alarm release on all circuits except box output and trouble resound fault supervision event recall feature to trap trouble conditions protection on all indicating release timer 0 10 or 15 minutes controls per initiating zone option Battery earth fault supervision and fuse protection on all indicating circuits Extensive transient protection 6.5 AH to 15 AH battery up to 90 hours standby Output circuits protected against false activa by 2 step command sequence and watchdog timer to supervise micropro Last event recall feature to trap intermittent trouble conditions Non regulated 24 VDC power output and RMS regulated 24 VDC output 2.25 amperes 230 VAC 50 Hz international option 4 wire smoke power output Slide in labels for zone identification Compliance Complies with NFPA 72 Local Auxiliary Remote Station Station and Proprietary Protective and Central Station Signaling Systems meets NFPA13 Installation of Sprinkler Systems NFPA15 Water Spray Fixed and NFPA16 Deluge Foam Water and Foam Water Spray Systems Meters Voltage and current meters 4XMM The 4XMM provides a to measure the voltage across the batteries and an ammeter to mea the charging current to the batteries Specifications Specifications 16.125 14.625 16.0 14.5 4.75 16.125 14.625 Specifications VAC 60 Hz 1.2 A Terminals AWG with 600 V insulation Circuit Specifications circuitry Style B Class B Style D A Specifications Voltage VDC ripple 10 mV peak to peak mA Current mA minimum Circuit Current mA maximum Detector Current In Standby mA peak per zone Loop Resistance ohms Resistor kohms 1 2 watt Circuits Detector Circuit 1 Manual Release Waterflow Supervisory Bell Style B D Detector Circuit 2 Style B D Waterflow Style B D Supervisory Style B D Circuits auxiliary relays track these circuits Alarm Waterflow Bell Style Y Z Releasing Circuit 1 Style Y Supervisory Bell Release Circuit 2 Y Panel Control Switches 1 Tone Silence 2 Alarm Silence 3 Alarm Activate 4 System Reset Specifications Smoke Detector Power Maximum Current mA RMS Regulated 24 VDC Power 24 VDC Power Output DC Current mA subtracted from four wire power Circuit Specifications circuitry Current amps max Current A subtracted from notification power dedicated to all out circuits Specifications VDC RMS regulated not filtered Voltage Drop Due To Wiring VDC Signaling Current Per Circuit amps AG 4 amps Resistor kohms 1 2 watt part no 71252 Program Selections DIP switch To Select Two zone single hazard operation Two zone single hazard operation cross zoned Two zone dual hazard operation combined release Two zone dual hazard operation split release Discharge times 0 10 or 15 minutes Standard Specified Requirements Communicator 911A Central Station service 72 Central Station Signaling System Remote Station Service 72 Remote Station Signaling System Module 4XTM Local Energy Municipal service NFPA 72 Protective Signaling Current mA Current amps subtracted from appliance power Wire Resistance Panel And Trip Coil ohms Voltage VDC Resistance ohms Polarity Output VDC Remote Station Service Remote Station Signaling System current allowed for circuits shall not exceed mA per circuit Boards PDRP 1001 has mounting slots for two option Any two of the three option modules may installed Relay Module 4XZM Zone Relay module provides Form C general and trouble contacts and the following relays Bell Bell Circuit 1 Bell Release Circuit 2 Form C Contacts rated for 2.0 amps 30 VDC resistive 0.5 amps 30 VAC resistive can be silenceable non silenceable by jumper Module 4XTM Transmitter module option provides a supervised for local energy municipal box transmitter NFPA 72 Auxiliary Protective Signaling System alarm and trouble reverse polarity for NFPA 72 Station Protective Signaling System Also is a DISABLE switch and disable trouble A jumper option allows the reverse polarity to open with a System Trouble condition if no condition exists Interface Module 4XLM module supports the RZA 4X Remote module The LED Interface Module to the main board occupying one of the two connectors Annunciator LED wiring is super for opens Faults will activate System Trouble Relays Form C Contacts Rating amps 30 VDC resistive amps 30 VAC resistive Annunciator Remote Annunciator mounts on a standard box and provides the following Trouble LED yellow Piezo Sounder Switch for local sounder Bell LED red Bell LED red Circuit 1 LED red Bell Release Circuit 2 LED red The Remote Annunciator requires the use of an interface module Sensor Sales and Service Sensor Headquarters Ohio Avenue Charles IL 60174 800 SENSOR2 630 377 6495 Sensor Canada 905.812.0767 905.812.0771 Sensor Europe 44.1403.891920 44.1403.891921 Sensor in China 86.29.8832.0119 86.29.8832.5119 Sensor in Singapore 65.6273.2230 65.6273.2610 Sensor Far East 85.22.191.9003 85.22.736.6580 Sensor Australia 613.54.281.142 613.54.281.172 Sensor India 91.124.237.1770 x 2700 91.124.237.3118 Sensor Russia 70.95.937.7982 70.95.937.7983 2004 System Sensor The company reserves the right to change product specifications without notice A05 0954 004

Related Files