System Sensor PDRP-1002

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-pdrp-1002-6028973514.pdf
Type PDF
Size 996.71 KB
Downloads

Text Preview

S P R I N K L E R S Y S T E M S M O N I T O R I N G Series Agent Control Panel Available Agent Releasing Panel International 230V Panel Accessories Available Zone Relay Module Transmitter Module LED Interface Module Volt Amp Meter Supervised Remote Annunciator LED interface module 4XLM 911A Digital Communicator Overview initiating device circuits Style B D notification appliance circuits Y Z release circuits Style Y switch input Style B D release input input option Style B audible indications for 1 zone in 2 zones in alarm release on all circuits except box output and trouble resound fault supervision event recall feature to trap trouble conditions protection on all indicating release timer 0 10 or 15 minutes controls per initiating zone option Battery earth fault supervision and fuse protection on all indicating circuits Extensive transient protection 6.5 AH to 15 AH battery up to 90 hours standby Output circuits protected against false activa by 2 step command sequence and watchdog timer to supervise micropro Last event recall feature to trap intermittent trouble conditions Non regulated 24 VDC power output and RMS regulated 24 VDC output 2.25 amperes 230 VAC 50 Hz international option 4 wire smoke power output Slide in labels for zone identification Compliance Complies with NFPA 71 Central Station Signaling System and 72 Local Auxiliary Remote Station Control Station and Proprietary Signaling Systems Also meets NFPA 12 CO2 high pressure only Systems and both NFPA 12A Halon 1301 Extinguishing Systems well as NFPA 12B Halon 1211 Extinguishing Systems Complies with special options for IRI New York City and other local jurisdictions Meters Voltage and current meters 4XMM The 4XMM provides voltmeter to measure the voltage across the batteries and an ammeter to the charging current to the batteries Specifications Smoke Detector Output Maximum 200 mA Regulated 24 VDC Power Maximum current A subtracted from notifi appliance power dedi to all output circuits 24 VDC Power Maximum DC current mA subtracted from four smoke power Relays Form C contacts rating amps 30 VDC resistive amps 30 VDC resistive Remote Station service Remote Station Signaling System current allowed both circuits shall not 10 mA per circuit polarity output voltage VDC Specifications 14.625 14.5 4.75 14.625 Specifications VAC 60 Hz 1.2 A Terminals AWG with 600 V Specifications Circuits Detector Zone 1 Style B D Detector Zone 2 Style B D Abort Style B D Manual Release Style B D Supervisory Style B Circuits Notification Circuit 1 one zone in alarm Notification Circuit 2 pulse with two zones in alarm and sound steady on release Releasing Circuit 1 Releasing Circuit 2 Panel Control Switches 1 Tone Silence 2 Alarm Silence 3 Alarm Activate 4 System Reset Circut Specifications circuitry Style B Class B Style D Class A Specifications voltage 24 VDC 10 mV peak to 5 mA current mA minimum circuit current mA maximum detector current standby 2 mA peak zone loop resistance ohms resistor Kohms 1 watt Circuit Specifications circuitry current 2.25 amps max signaling current per 1.5 amps 2 AG 4 amps Resistor 4.7 Kohms watt part no 71252 Specifications 24 VDC RMS regu not filtered voltage drop due to 1.5 VDC Standard Specified Requirements Communicator 911A Central Station ser NFPA 72 Central Protective Signaling or Remote Station NFPA 72 Remote Protective Signaling Module 4XTM Local Energy Municipal service NFPA 72 Protective System current mA current amps subtracted from appliance power voltage VDC resistance ohms wire resistance panel and trip coil ohms Boards PDRP 1002 has mounting slots for two option Any two of the three option modules may installed Relay Module 4XZM Zone Relay module provides Form C general and trouble contacts and the following relays Bell Bell Circuit 1 Bell Release Circuit 2 detector in alarm detectors in alarm Circuit 1 Activated Circuit 2 Activated can be silenceable non silenceable jumper Module 4XTM Transmitter module option provides a super output for local energy municipal box trans for NFPA 72 Auxiliary Protective Signaling and alarm and trouble reverse polarity NFPA 72 Remote Station Protective Signaling Also included is a DISABLE switch and trouble LED A jumper option allows the polarity circuit to open with a System condition if no alarm condition exists Interface Module 4XLM module supports the RZA 4X Remote module The LED Interface Module to the main board occupying one of the option connectors Annunciator LED wiring is for opens Faults will activate System condition Annunciator Remote Annunciator mounts on a standard box and provides the following Trouble LED yellow Piezo Sounder Switch for local sounder Circuit 1 LED red Circuit 2 LED red Circuit 1 LED red Circuit 2 LED red The Remote Annunciator requires the use of LED interface module Sensor Sales and Service Sensor Headquarters Ohio Avenue Charles IL 60174 800 SENSOR2 630 377 6495 x3 Sensor Canada 905.812.0767 905.812.0771 Sensor Europe 44.1403.276500 44.1403.276501 Sensor in China 86.29.524.6253 86.29.524.6259 Sensor in Singapore 65.6273.2230 65.6273.2610 Sensor Far East 85.22.191.9003 85.22.736.6580 Sensor Australia 613.54.281.142 613.54.281.172 Sensor India 91.124.637.1770 x 2700 91.124.637.3118 2003 System Sensor The company reserves the right to change product specifications without notice A05 1008 001

Related Files