System Sensor SA PA400, PA400B, PA400R and PA400W Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-sa-pa400-pa400b-pa400r-and-pa400w-manual-6543910782.pdf
Type PDF
Size 608.67 KB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Series Mini Sounders models add suffix available as regulated 24VDC only Add suffix for red models for models for Beige model PA400 add suffix to models with fire printed on front products to which this manual applies may be covered by one or more of the following U S Patent numbers 5,546,293 and 5,488,462 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Sounder Regulated 12DC and 24DC Voltage Limits 8 and 16 Operating Current At 12V 20.8mA at 24V 47.4mA Range to 60 14 to 140 0 to 49 32 to 120 with strobe added Output 74dBA minimum 10 feet 12 volt application 80dBA minimum 10 feet 24 volt application All PA400 series models were only tested at the 8 and 16 Volt DC limits This does not include the 80 low end or high end voltage limits Shown with control panel in alarm Panel polarity in supervisory condition Information National Fire Protection Association has published codes and recommended practices for the installation and of the above appliances Therefore the installer must be with these requirements with local codes and any spe requirements of the authority having jurisdiction PA400 PA400W white PA400R red and PA400B beige Piezo electronic sounder is intended to be connected to the alarm circuit of a UL listed 12 or 24 VDC fire alarm control 1 Notes wiring must be in compliance with all codes and must not of such length or wire size that would cause the appliance to outside of its published specifications The appliances also be tested after installation in accordance with the con panel manufacturer test procedure Do not loop wires under terminal screws Wires con the device to the panel must be broken at the screw terminal in order to maintain electrical Sounders The PA400 is intended for mounting to a standard 21 deep box which allows sufficient clearance for conduit The PA400 is compatible with DC line supervision The Piezo is polarized and has terminals marked with polarity positive supply voltage to the terminal and nega supply voltage to the terminal See Figure 1 Mount the appliance to the electrical outlet box using the two screws supplied Field repair of the PA400 should not be attempted Return to for repair or replacement 1 I56 0305 011R

Related Files