System Sensor SA RP2475ADA

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-sa-rp2475ada-7021948653.pdf
Type PDF
Size 657.15 KB
Downloads

Text Preview

RP12 24ADA Strobe Plate Division of Pittway Ohio Avenue St Charles IL 60174 736 7672 Fax 630 377 6495 Available Sensor RP12 24ADA Series Strobe Retrofit complies with the Americans with Disabilities Act and the demanding requirements of the UL 1971 for the Hearing Impaired The 15 75 version is 1971 listed at 15 cd new model RP12 24ADA Series Retrofit Plate adding an ADA compliant visible notification to existing 4 or 5 inch square horns or speakers To compliance with ADA and UL 1971 use the System 75 candela models for non sleeping areas and the candela models for sleeping areas in red only at 12 or 24 VDC the RP12 Series Strobe Retrofit Plate can be mounted to a standard 4 backbox Fits most 4 or 5 square horn or speaker Multiple light intensities VDC 15,15 75 75 or 110 cd models VDC 15 or 15 75 cd models Low strobe current draw 93 mA on the RP241575ADA regulated power Low installed cost No measurable strobe in rush in excess of peak current Intended for primary signaling Easy terminal strip strip guage and wiring on back Wall mount only terminals Weight Strobes oz 397g 4 11 2 standard backbox recommended 4 11 2 standard backbox recommended 12 AWG Range F to 120 cid 176 F 0 cid 176 C to 49 cid 176 C System Sensor 8 96 document is not intended to be used for installation purposes Description new model RP12 24ADA Series Retrofit Plate allows an ADA compliant visible notification appliance to existing 4 or 5 inch square horns or speakers All Series Strobe Retrofit Plates are suitable for signaling in public mode life safety applications Strobe Retrofit Plates can be connected to the alarm circuit of a UL listed fire alarm control panel Ratings Strobe Only are compatible with DC line supervision Panels may full wave rectified unfiltered power supplies The Retrofit Plates are available for 24VDC operation or operation The strobe features low current draw no measurable in rush in excess of peak current The Retrofit Plate is intended for wall mounting only to 4 square electrical backbox Current in of Peak Current Regulated mA Operating from Wave Rectified Operating mA Range Current mA For additional information see installation manual D900 09 00 12 volt operating voltage cannot be less than 8.5 VDC or greater than 18.7 VDC actual 24 volt operating voltage cannot be less than 16 greater 33 VDC Supply mArms Specifications Strobe Retrofit Plate shall be a System Sensor Model listed to Standard UL 1971 for the Hearing and shall be approved for Fire Protective Service ADA Strobe Retrofit Plate series shall retrofit most 4 5 square horn or speaker into an ADA compliant notification device Strobe Retrofit Plate shall be as a Primary Signaling Notification appliance Strobe Plate shall also comply with the Americans with Act requirements for visible signaling Strobe Retrofit Plate shall operate on 12 or from a regulated DC supply or full wave rectified supply The Strobe Retrofit Plate shall be from a non coded power supply when powered horn or speaker Strobe Retrofit Plate shall have no in rush current in excess of operating peak Visual signaling devices are to be installed in all and sleeping areas per plans and The strobe light shall consist of a xenon tube and associated lens reflector system All Strobe Plates shall be capable of mounting to a standard 4 11 2 backbox 2 Light Distribution Dispersion AXIS of Rating Dispersion 5 30 of Rating 5 25 30 45 polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired with minimum intensity percentages as shown in the graphs above With its specially designed lens reflector system the RP12 24ADA Strobe Plate Series meets or exceeds these requirements at all angles Next EOL VDC VDC VDC VDC BE OUT OUT OUT OUT or Next EOL VDC VDC or OUT OUT OUT OUT Horn Strobe Wiring Use uncoded supply only Horn Strobe Wiring Strobe Retrofit Plate 4 Horn Strobe Retrofit Plate 5 Speaker 3 Current mA VDC VDC VDC VDC VDC VDC to be 75 cd at 0 viewing angle See Light Distribution Graph Information ADA Compliant UL 1971 Listed Retrofit Plates Strobe Retrofit Plate Strobe Retrofit Plate Strobe Retrofit Plate Strobe Retrofit Plate Strobe Retrofit Plate Strobe Retrofit Plate to Order Strobe 15 cd UL 1971 Strobe 75 cd UL 1971 Strobe 110 cd UL 1971 Strobe 15 cd UL 1971 12 Volt 24 Volt Signal Strobe Mini Alert Sounder Strobe Retrofit Plate Multi Alert Sounder Strobe Multi Alert Sounder Strobe with Electromechanical Tone 400 Series Speaker Red SP101 Series Speaker Strobe Red SP101 Series Speaker Strobe White Sensor Worldwide Distribution India Canada Sensor India Sensor Canada Maheshwari Nagar Kitimat Road Unit 7 Mills Lane Ontario East Mumbai 400093 L5N 3T5 91 022 8202564 905 812 0767 905 812 0771 the United Kingdom Sensor Europe Ltd Gates III North St West Sussex 5PJ United Kingdom 44 1403 276500 44 1403 276501 4 the Far East Sensor Far East Ltd 706 World Shipping Centre Canton Road Kowloon Hong Kong 852 2730 9090 852 2736 6580

Related Files