Technical Data TD450106EN control unit Autonomous Control Unit ACU 8421 part of the ALERiTY MNS platform is a supervised in building emergency system that is integrated with the WAVES over Mass Notification System MNS for site wide communications unit provides paging background music messaging and voice communications with 24 VDC battery backup Individual Building System provides full control of building appliances such as loudspeakers and strobe lights ACU 8421 includes a SAFEPATH SP40S IP Communicator an Ethernet communication network device interface cable The ACU 8421 can be controlled and monitored through WAVES over IP WoIP Integrated Base Station which can send to one ACU 8421 or multiple ACUs An Eaton approved RADIO 900M and RADIO 500G can be added for wireless single channel system is capable of delivering 40 watts of high fidelity audio power and 2 amps of supervised VDC synchronized strobe power It comes standard with an digital voice messaging system with 8 standard a hand held microphone power supply battery and numerous additional features The ACU 8421 system expandable to 5280 watts utilizing the SPB 80 4 80 watts and amps of strobe power the SPB 160 160 watts or SPB 320 watts supervised audio power boosters All models available 115 VAC or 220 VAC August 2017 Supersedes October 2016ACU 8421firealarmresources com Data TD450106EN August 2017 with WoIP for a site wide IP based MNS with fire alarm systems Continuous Self Monitoring BIT Built In Test information from WoIP ACU is transmitted to the WoIP Integrated Base Station music Capable of broadcasting from a supplied background music source Unique supervision method allows for full system supervision during background music Line Level input for music source Frequency Response 100 paging Easily interfaces with most existing phone system page port port and line level signals Automatically mutes BGM Frequency Response 275 Night ringer or security alert connection evacuation Supervised NAC speaker and strobe circuits Live microphone override 8 digitally pre recorded voice messages Uses selectable pre tones for messages inputs and activation 2 Amps of 24 VDC supervised strobe power with built in sync protocol Power limited Strobe output is selectable for control of Wheelock sync or non sync operation Strobe terminals have pass through capability for Wheelock or non sync operation Messages can be dip switch selected to activate strobes MIC activation can be dip switch selected to activate strobes Auxiliary activation Remote MIC can be dip switch selected activate strobes 24 VDC supervised and synchronized strobe power can be to meet the requirements of the installation via to optional Wheelock power boosters output 40 watts of supervised audio power Speaker outputs 25V or 70.7V power limited activation Contact closure message activation processing Volume and tone controls for general paging and BGM Connectivity of optional speaker splitter modules Dual tone tone generator with Code 3 Tone and Slow Whoop alerting of system trouble Night ringer security alerting capability Audio power can be expanded by connecting to optional audio boosters SPB 80 4 80 watt supervised audio power booster with Amp of Synchronized Strobe Power SPB 160 160 watt supervised audio power booster SPB 320 320 watt supervised audio power booster pre recorded message announcement Supplied with 8 pre recorded emergency messages Capable of in field recording of all messages via 1 8 line level input jack Preset audio levels for emergency messaging prerecorded and mic reverts back to a preset level regardless of volume set for BGM or general paging On board push to talk microphone Telephone paging input disconnects BGM when in use Auxiliary input for remote microphone connection supply batteries 24 VDC 33AH max rechargeable battery back up power built in Batteries can be housed in the enclosure Up to two BAT 1212 volt 12 ampere hour batteries can fit in the enclosure Actual size required will depend on speaker and or strobe load are sold separately CAUTIONS and WARNINGS are identified by the symbol warnings are printed in bold capital letters WARNING READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION CAREFULLY BEFORE USING SPECIFYING OR APPLYING PRODUCT FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION AND OR OPERATION OF THESE PRODUCTS IN AN SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS Advantages One system multi function facility communications system Background Music BGM system with patent pending during BGM operation with telephone system for general paging requirements Supervised emergency fire voice evacuation system Built in power for visual notification appliances e g strobes Expandable for larger system requirements optional equipment compliance SP40S UL 864 UL 1711 ULC S527 California State Fire Marshal New York City MEA FCC Part 15 ICES IPC 8020 T certification 60950 1 Part 15 ICES Multi use applicationse The system can function as an evacua system an emergency messaging system a paging system employee notification system and a background music system NFPA 72 2002 section 6.8.4 Combination Systems with fire alarm systems and provides a signal for deactivation of fire alarm audible notification devices fire alarm system appliances are reactivated after the mass voice messages are delivered Economic OSHA applicationse The system is OSHA 1910.165 and therefore it does not require reliability inspections two months or the required spare parts inventory www eaton comACU 8421firealarmresources com Technical Data TD450106EN August 2017 Wide ranging applications small to large facilities Can connect to pagers for private alerting of emergency conditions maintenance Multiple trouble LED indicators for quick system diagnostics Fully supervised circuitry always in effect during BGM and paging via patent pending technology Removable quick connect disconnect terminals for ease of wiring 12 to 22 AWG Power limited circuitry with Class or Class wiring only with use of audio splitter Surge protected circuitry Audio and strobe power limiter reset button Wheelock Products All Wheelock speaker strobes All Wheelock strobes All Wheelock speakers All cluster speakers Wheelock strobe power supply 1 Inputse Audio Activation Ordered Inputs Board Microphone Message Input 1 Message Input 2 Message Input 3 Message Input 4 Message Input 5 Message Input 6 Message Input 7 Message Input 8 Ringer Input Paging Input Music Input Level Type of Input Closure activation to Talk PTT Microphone Microphone or Remote Microphone Expander Closure input port input Level Input 600 ohm input voltage must be less than 2.5 V peak to peak 0.3 volts RMS 2 Inputse Audio Technical Specificationsa 3 SP40S Mechanicala mode Class D amplifier 40 Watts Response Ratio Range Harmonic Distortion by Current Draw Current Draw or 70.7V power limited 275 Hz 6.5 kHz 100 Hz 15 kHz UL Voice Evacuation Requirements of Hz than 65 dB than 65 dB than 2 mA amps Lock For inf

Related Files