Technical Data TD450036EN DoD facility communications expansion options Communications System for DoD Facilities 2 4 Options 2 zone Class A or 4 zone Class B speaker audio splitter 5 audio boosters 6 7 diagram 8 9 addressable paging splitter and telephone zone controller 10 supervised volume control and remote microphone 11 microphone expansion module 12 13 and engineers specifications 14 16 February 2016 Supersedes September 2011SP40S D Product Linefirealarmresources com Data TD450036EN February 2016 DoD Facility SP40S D for Department of Defense DoD facilities the SP40S D is Multi Function Supervised Personnel Alerting Paging Background BGM delivery and Emergency Voice Evacuation System 24 VDC battery backup The SP40S D integrates with fire alarm and provides full control of building audible and visual noti appliances This single channel system is capable of deliver 40 watts of supervised high fidelity audio power and 2 amps of 24 VDC synchronized strobe power It comes standard an on board digital voice messaging system with 8 standard a hand held microphone power supply battery charger numerous additional features The SP40S D system is expand to 5280 watts utilizing the SPB 80 4 80 watts and 4 amps of power the SPB 160 160 watts or SPB 320 320 watts audio power boosters All models are available in 115 VAC 220 VAC meet the UFC requirement for automatic alarm audible shutoff 10 minutes the SP40S D includes a 10 minute time out feature automatically deactivates Fire and Emergency digital voice messages inputs 1 6 after 10 minutes Alarm DV messages 7 and 8 do not automatically time out evacuation Supervised NAC speaker and strobe circuits Live microphone override 8 digitally pre recorded voice messages Emergency digital voice message pushbutton and CC control automatically deactivate after 10 minutes Selectable pre tones for messages music Capable of broadcasting from a supplied BGM source Unique supervision method allows for full system supervision during background music Line Level input for music source Frequency Response 100Hz paging Easily interfaces with most existing phone system page port port and line level signals Automatically mutes BGM Frequency Response 275 5kHz Night ringer or security alert connection inputs and activation 2 Amps of 24 VDC supervised strobe power with built in sync protocol Power limited Strobe output is selectable for control of Wheelock sync or non sync operation Strobe terminals have pass through capability for Wheelock sync non sync operation Any of the 8 messages can be dip switch selected to strobes strobes Microphone activation can be dip switch selected to Auxiliary activation Remote MIC can be dip switch selected to strobes 24 VDC supervised and synchronized strobe power can be to meet the requirements of the installation via to optional Wheelock power boosters output 40 watts of supervised audio power Speaker outputs 25V or 70 7V or 100V power limited activation Contact closure message activation processing Volume and tone controls for general paging and BGM Connectivity of optional speaker splitter modules Dual tone tone generator with Code 3 Tone and Slow Whoop alerting of system trouble Night ringer security alerting capability Audio power can be expanded by connecting to optional audio boosters SPB 80 4 80 watt supervised audio power booster with Amp of Synchronized Strobe Power SPB 160 160 watt supervised audio power booster SPB 320 320 watt supervised audio power booster pre recorded message announcement Supplied with 8 pre recorded emergency messages Capable of in field recording of all messages via 1 8 line level input jack Preset audio levels for emergency messaging prerecorded and mic reverts back to a preset level regardless of volume set for BGM or general paging On board push to talk microphone Telephone paging input disconnects BGM when in use Auxiliary input for remote microphone connection supply batteries 24 VDC 33AH max rechargeable battery back up power built in Batteries can be housed in the enclosure Up to two BAT 1212 volt 12 ampere hour batteries can fit in the enclosure Actual size required will depend on speaker and or strobe load are sold separately CAUTIONS and WARNINGS are identified by the symbol warnings are printed in bold capital letters WARNING READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION CAREFULLY BEFORE USING SPECIFYING OR APPLYING PRODUCT FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION AND OR OPERATION OF THESE PRODUCTS IN AN SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS advantages One multi function in building DoD communications system www eaton comSP40S D Product Linefirealarmresources com Data TD450036EN February 2016 Background Music BGM system with patent pending during BGM operation strobes and notification appliance circuits NAC for visual with telephone system for general paging requirements Supervised emergency fire voice evacuation system Built in power for visual notification appliances e g strobes Expandable for larger system requirements optional equipment Economic OSHA applicationse The system is OSHA 1910 165 and therefore it does not require reliability inspections two months or the required spare parts inventory Wide ranging applications small to large facilities Can connect to pagers for private alerting of emergency conditions maintenance Multiple trouble LED indicators for quick system diagnostics Fully supervised circuitry always in effect during BGM and paging via patent pending technology Removable quick connect disconnect terminals for ease of wiring 12 to 22 AWG Power limited circuitry with Class or Class wiring only with use of audio splitter Surge protected circuitry Audio and strobe power limiter reset button Wheelock Products All Wheelock speakers speaker strobes strobes cluster speakers Wheelock strobe power supply compliances Approvals UL Standard 864 9th edition UL Standard 1711 State Fire Marshal CSFM New York City MEA Part 15 Meets UFC 10 minute message time out requirement OSHA 1910 165 and ADA Compliant 1 year warranty Activation Contact closure or DV message pushbutton activation Multi use applicationse The system can function as an system an emergency messaging system a paging an employee notification system and a background music per NFPA 72 Fire code applicationse The syst

Related Files