Fike Fire Digital Alarm Communicator Transmitter DS9471

File Preview
File Preview
Click below to download for free

File Data

Name fike-fire-digital-alarm-communicator-transmitter-ds9471-8619340257.pdf
Type PDF
Size 645.52 KB
Downloads

Text Preview

Fire Digital Alarm Communicator Transmitter 3 Zone Control Transmitter complete kit includes phone cords and enclosure with a hard wired transformer in it Order a battery to complete installation Control Communicator DACT This is dialer only Select from the accessories complete the installation DS9471 is a Three Zone Digital Alarm Control Transmitter DACT It can be used in stand alone applications or in slave applications off premises monitoring of an existing Fire Alarm Panel FACP It communicates using BFSK or tone One is a four wire Class A NFPA Style D Alarm Circuit In a stand alone application this zone monitor up to five waterflow alarm switches or up to mechanically operated devices such as heat and manual pull a slave this zone monitors an alarm output on an FACP Zones Two and Three are Class B NFPA A Supervisory Circuits a stand alone each circuit may monitor up to 20 sprinkler devices In a slave application these zones monitor a trouble output on an existing FACP Features Stand alone Control Sprinklers Slave for Existing Systems Three Zones Two Optional Relay Connections Automatic Test Reports Dual Telephone Lines Built in Telephone Trouble LED and Buzzer Primary and Alternate Phone Numbers UL Listed Basic Functions Relays Two separate relay sockets provide connection points optional D136 relays These relays provide outputs Phone Trouble and Alarm Initiation Line Connections Two modular phone jacks on the DS9471 provide for two separate telephone lines using or RJ38X jacks Both telephone lines are If one of the phone lines is operational the other is not a report is sent to the receiver Line Trouble LED A yellow LED provides a visual of trouble on either telephone line The LED is visible a hole in the DS9471 cover Trouble Buzzer A buzzer provides an audible indication of phone The buzzer LED and the optional relay all the phone trouble The buzzer automatically when a phone trouble signal is communicated the receiver Certifications Standard Control Units System Technical Specifications Digital Alarm Communicator Transmitter Data only in 12 VAC Mode Battery for emergency standby for each 72 the capacity is at least 24 hours up to 60 hours plus 5 minutes of operation Power VAC 20 VA with 12 VDC battery or VDC from existing FACP Panel Voltage 8.5 VDC Current idle mA 12 VAC Mode mA 24 VDC Mode Current maximum mA 12 VAC Mode mA 24 VDC Mode a three zone digital alarm unit transmitter DACT It uses phone lines to transmit the A phone fail LED and buzzer phone line failures Zone 1 is Class A NFPA Style D Alarm Initiating In stand alone applications Zone can monitor up to 5 waterflow alarm or up to mechanically devices In slave applications 1 can monitor an alarm output on an FACP Zones 2 and 3 are Class B Style A Supervisory Circuits circuit can monitor up to 20 sprinkler devices in a stand alone or can monitor a trouble on an existing FACP in a slave 1 0.2 to 90 seconds depending on time 2 Approx 2 4 seconds Information Optional Accessories mounted in a non control red plastic housing The small size allows it be in economical for stand alone applications DS9471 has a sliding cover which to expose the terminal strip jack and the two relay The DS9471 measures 7.8 in x in 7.80 cm x 4.40 cm Applications normally open contact of switches maximum of 5 or activated uniting devices on to Zones 2 and or 3 Communicator Applications Zone 1 to a common alarm normally open dry closure on the Connect terminals 6 and 7 to the contact Restart time and time must be programmed for seconds when connecting the Alarm circuit an existing control Connect FACP common trouble to Zones 2 and or 3 Relay K5 enables Phone Line Relay K6 enables initiating Circuit Relay D161 D162 Modular Telephone Cord 7 ft 2.1 m conductor fully modular plug in cord for to RJ31X or RJ38X Telco jack Modular Telephone Cord 2 ft 60 cm conductor fully modular plug in cord for to RJ31X or RJ38X Telco jack Time Voltage and 10 VDC 10 mA 48 52 VDC to 120 0 to 49 Specifications to Article 760 of NEC NFPA 70 D1220 Transformer 120 VAC only D5050 Handheld Programmer 34902E Systems Inc Perinton Parkway Fairport New York 14450 9199 223 4060 cid 1 Cust Service 888 289 0096 585 223 9180 cid 1 Faxback 800 315 0470

Related Files