Fike Manual Actuator C 1 09 01
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-manual-actuator-c-1-09-01-6819745023.pdf |
---|---|
Type | |
Size | 738.83 KB |
Downloads |
Text Preview
MANUAL ACTUATOR Manual Actuator MA Fike P N 10 2225 provides an independent means operating Fike clean agent systems which use the Gas Cartridge Actuator It is designed to allow activation of GCAs in stand alone mode or to a normal releasing system in the event of a total power loss MA consists of a DC generator and a supervisory module The generator enough energy to fire up to six GCAs The supervisory module the field wiring between the MA and each GCA The supervisory annunciates a trouble condition by the transfer of two sets of normally relay contacts The supervisory module requires a separate 24Vdc source Since the DC generator does not require a 24Vdc power source is not required to activate the GCAs MA provides two green LEDs for indication of system status The green LED indicates status of 24Vdc power If the LED is not illuminated then power is not present The green GCA circuit LED indicates a GCA wiring If an open exists in the GCA wiring or 24Vdc power is not present then green LED will not illuminate MA also provides two sets of normally energized relay contacts A loss of power and or an open in the GCA wiring will cause the relay contacts transfer MA also provides an arm disable switch which will safely disconnect the MA the GCA circuit for testing or maintenance purposes The switch will not the GCAs from other sources of power such as a releasing panel operate the MA simply pull the ring pin and push the handle up a quarter This action will provide the power necessary to activate all GCAs Exit the area Manual Actuator should be mounted as close to the Clean Agent containers possible Consideration should be given for convenience of operation and from the hazard area FEATURES SPECIFICATIONS No External Power Required No Stored Energy Supervision of Connectors Two Step Operation Activates up to Six Containers Actuator Ratings 24 Volt Power Supervision only 18 31 volts DC 50 ma max GCA Circuit 10 ohms max field wiring plus GCAs Relay Contact Ratings DC operation 2A 30V AC operation 0.5A 110V Manual Actuator UL Listed S5566 No C 1.09.01 2 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com DIAGRAM FIRING CIRCUIT III III III WIRING 1 2 3 DEPICTS 3 GCA UP TO 6 CAN BE USED MANUAL ACTUATOR ACTUATOR CONTACTS Fike Corporation All Rights Reserved No C 1.09.01 2 March 2005 Specifications are subject to change without notice